1200kmSECURITY RESEARCH
Loading interactive filters…

1200KM / telemetry

Process History/Live Data — Detection Telemetry

Time-series measurements of an industrial process, including historical and live values.

Collection and providers

Export historian/process tags with engineering units, quality and source timestamps; define expected sample rate and compare an independent signal.

  • OPC UA audit-capable servers: Auditable actions where supported and enabled; inspect server conformance and vendor documentation.
  • Controller, HMI and historian exports: Vendor-specific process values, quality flags, alarms and operational context.
  • Independent lab sensors / safety records: Physical-effect corroboration, not a universal cybersecurity log format.

Configuration

  • Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.
  • Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.
  • Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs.

Synthetic event example

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0107",
  "collector": "illustrative-lab-collector",
  "observation": {
    "tag": "LAB.TankLevel",
    "value": 42,
    "unit": "percent",
    "quality": "good"
  }
}

Visibility and validation

There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.

  • Record the lab scope, collector version, effective configuration and expected source fields before testing.
  • Use an approved benign action or read-only snapshot appropriate to this type. For destructive, privileged or physical effects, use a reviewed fixture or existing authorized evidence instead of causing the effect.
  • Verify the native source record locally and at the collector; compare timestamps, identity, object, action/result and the type-specific fields listed below. Save a redacted real capture separately from the synthetic example.
  • Check a normal baseline and collector-loss case. Fixture parsing proves parser behavior only; it does not prove sensor coverage or malicious-behavior detection.

Primary sources

Connected ecosystem references

Linked tags

Each workspace retains its own logsource and platform requirements. A technique-level association is not a per-rule sensor mapping.

Attack tools through shared TTPs

These are two-hop navigation links through explicitly associated techniques, not independent tool-to-sensor assertions.

No reviewed association in this snapshot.

Pinned research references. No browser attack runner, live simulation result or validated detector is asserted. Source mappings and validation limits are preserved. ATT&CK / Atomic provenance · Detection provenance.