1200KM / detection
T0836 Modify Parameter — Detection Rules
Detection workspace for T0836 Modify Parameter: 0 Sigma sources, 0 Atlas concepts and 0 anomaly models. No live detection validation.
Source-backed rule directory
No reviewed association in this snapshot.
Atlas deterministic concepts
No exact concept selected.
Anomaly models
No exact Atlas model in this snapshot.
ATT&CK analytic guidance
DET0776 Detection of Modify Parameter
AN1908 Analytic 1908
Real-time monitoring identifies an Industrial Control System (ICS) protocol write to a parameter/setpoint register where the written value falls outside the documented safe operating range, or where the write originates from a source not in the approved write-source list, correlated with subsequent historian tag drift. Documented precedent: FrostyGoop directly modified Modbus holding register values on ENCO heating controllers in Lviv, Ukraine, causing a two-day remediation outage. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.
AN2145 Analytic 2145
Real-time monitoring identifies a Linux process invoking Industrial Control System (ICS) vendor write Application Programming Interfaces (APIs) or Open Platform Communications (OPC) Unified Architecture (UA) write calls to setpoint tags on field devices, from a User Identifier (UID) not associated with the authorized control application, with values exceeding the safe operating range. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.
AN2209 Analytic 2209
Real-time monitoring identifies a process on an Industrial Control System (ICS) Windows host writing setpoint values to Open Platform Communications (OPC) Data Access (DA)/Unified Architecture (UA) tags or historian writable tags without being the recognized Supervisory Control and Data Acquisition (SCADA) or Distributed Control System (DCS) control application, with values falling outside the normal operating range. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.
Connected ecosystem references
Linked tags
Simulation, tools and telemetry
No reviewed association in this snapshot.
Existing anomaly research
Complete technique engineering workbook
Collection configuration and event examples · Anomaly models and design worksheet · Tools and documented software · Simulation procedures · Offline synthetic collection check
Exact source tags are not semantic relevance verdicts. Review actual rule conditions and observation points; imported rules are not backend-compiled or live-validated.
Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.