Complete technique description
Adversaries may send unauthorized command messages to instruct control system assets to perform actions outside of their intended functionality, or without the logical preconditions to trigger their expected function. Command messages are used in ICS networks to give direct instructions to control systems devices. If an adversary can send an unauthorized command message to a control system, then it can instruct the control systems device to perform an action outside the normal bounds of the device's actions. An adversary could potentially instruct a control systems device to perform an action that will cause an Impact.[Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011]. An adversary could also misuse control system devices to store data collected from the network for later use.
In the Dallas Siren incident, adversaries were able to send command messages to activate tornado alarm systems across the city without an impending tornado or other disaster.[Zack Whittaker April 2017][Benjamin Freed March 2019]
Official technique definition · Open in the interactive matrix
Parent and sub-techniques
Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.
Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
Application Log Content · source-mapped
DC0038 collection page — Select the application event family required by the detection and document its native schema before normalization.
Providers and collection configuration
- Enable the application audit category or instrument the owned lab application at the authorization/action boundary.
- Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.
- Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart.
Required normalized fields: service, action, actor, record_count, result.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0038",
"collector": "illustrative-lab-collector",
"observation": {
"service": "lab-portal",
"action": "export_requested",
"actor": "lab-reader",
"record_count": 3,
"result": "authorized"
}
}
Visibility limits: Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.
Network Traffic Content · source-mapped
DC0085 collection page — Scope approved packet capture/protocol content collection to the lab flow; retain capture provenance and truncation indicators.
Providers and collection configuration
- Zeek: Connection and protocol metadata from traffic visible to the sensor.
- Suricata EVE: Configured flow, alert, DNS, HTTP, TLS and protocol records.
- Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.
- Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.
- Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection.
Required normalized fields: flow_id, protocol, method, path, payload_excerpt.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0085",
"collector": "illustrative-lab-collector",
"observation": {
"flow_id": "lab-flow-1",
"protocol": "http",
"method": "GET",
"path": "/lab-check",
"payload_excerpt": "LAB_TELEMETRY_CHECK"
}
}
Visibility limits: Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.
Process History/Live Data · source-mapped
DC0107 collection page — Export historian/process tags with engineering units, quality and source timestamps; define expected sample rate and compare an independent signal.
Providers and collection configuration
- Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.
- Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.
- Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs.
Required normalized fields: tag, value, unit, quality.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0107",
"collector": "illustrative-lab-collector",
"observation": {
"tag": "LAB.TankLevel",
"value": 42,
"unit": "percent",
"quality": "good"
}
}
Visibility limits: There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.
Process/Event Alarm · source-mapped
DC0109 collection page — Export alarm/event history with setpoint context and lifecycle transitions; retain suppressed/shelved state when provided.
Providers and collection configuration
- Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.
- Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.
- Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs.
Required normalized fields: tag, alarm, threshold, value, acknowledged.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0109",
"collector": "illustrative-lab-collector",
"observation": {
"tag": "LAB.TankLevel",
"alarm": "high_level",
"threshold": 80,
"value": 82,
"acknowledged": false
}
}
Visibility limits: There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.
Simulation design and documented procedures
Atomic evidence: no compatible candidate in this snapshot. Live lab status: not run for these imported procedures.
Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.
No compatible Atomic procedure is present in this pinned evidence set. Technical feasibility has not been ruled out. A custom procedure must define the behavior, target, collection point, success observable and rollback before execution.
Technique-specific experiment contract
- Choose one procedure implementing T1692.001 Command Message; identify the observable behavior in the source definition, not just its tactic.
- Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
- Enable the collection sources above and verify a benign baseline reaches the detector.
- Run only the approved isolated scenario; capture native events and an independent behavior observable.
- Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.