1200KM / detection
T0878 Alarm Suppression — Detection Rules
Detection workspace for T0878 Alarm Suppression: 0 Sigma sources, 0 Atlas concepts and 0 anomaly models. No live detection validation.
Source-backed rule directory
No reviewed association in this snapshot.
Atlas deterministic concepts
No exact concept selected.
Anomaly models
No exact Atlas model in this snapshot.
ATT&CK analytic guidance
DET0728 Detection of Alarm Suppression
AN1861 Analytic 1861
Real-time monitoring of the alarm and process historian layer identifies an alarm status transitioning to suppressed, shelved, disabled, or acknowledged without a corresponding operator action recorded within a grace period, correlated with Industrial Control System (ICS) protocol write traffic to alarm configuration or threshold registers arriving in the same window from a source not in the approved engineering list. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.
AN2107 Analytic 2107
Real-time monitoring identifies a write to alarm configuration files on a Linux-based Supervisory Control and Data Acquisition (SCADA)/alarm server by a User Identifier (UID) that is not the alarm management service, or the alarm management service process receiving Application Programming Interface (API) calls that suppress alarm classes without a corresponding operator session. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.
AN2108 Analytic 2108
Real-time monitoring identifies a write to alarm configuration files or database tables on an Human-Machine Interface (HMI)/alarm server by a process other than the recognized alarm management application, or an alarm-class-disable Application Programming Interface (API) call logged without a corresponding operator session ID in the HMI audit trail. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.
AN2188 Analytic 2188
Real-time monitoring identifies a network-device ACL, filter, or rate-limit policy change that suppresses or blocks ICS alarm-notification traffic outside the approved network-change baseline. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.
Connected ecosystem references
Linked tags
Simulation, tools and telemetry
- Application Log Content · DC0038
- Device Alarm · DC0108
- File Creation · DC0039
- File Modification · DC0061
- Network Traffic Content · DC0085
- Network Traffic Flow · DC0078
- Process History/Live Data · DC0107
- Process/Event Alarm · DC0109
No reviewed association in this snapshot.
Existing anomaly research
Complete technique engineering workbook
Collection configuration and event examples · Anomaly models and design worksheet · Tools and documented software · Simulation procedures · Offline synthetic collection check
Exact source tags are not semantic relevance verdicts. Review actual rule conditions and observation points; imported rules are not backend-compiled or live-validated.
Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.