1200kmSECURITY RESEARCH
Loading interactive filters…

1200KM / detection

T0814 Denial of Service — Detection Rules

Detection workspace for T0814 Denial of Service: 0 Sigma sources, 0 Atlas concepts and 0 anomaly models. No live detection validation.

Source-backed rule directory

No reviewed association in this snapshot.

Atlas deterministic concepts

No exact concept selected.

Anomaly models

No exact Atlas model in this snapshot.

ATT&CK analytic guidance

DET0723 Detection of Denial of Service

AN1856 Analytic 1856

Real-time network monitoring identifies a sustained spike in malformed or high-volume Industrial Control System (ICS) protocol traffic directed at a single field device from a source not in the approved control server list, immediately followed by that device dropping out of the supervisory poll cycle. Documented precedent: Sandworm's Industroyer malware sent a crafted 18-byte proprietary User Datagram Protocol (UDP) packet to port 50000 on Siemens Protection Technology (SIPROTEC) relays (CVE-2015-5374), causing the device to hang and require a manual reboot. OT operational-fidelity gate: Alert only when a device-specific traffic/resource threshold is exceeded and the same window shows service degradation, failed polling, device alarm/restart, resource exhaustion, or malformed/out-of-spec protocol behavior. Suppress planned load tests, maintenance, network convergence/failover, and known equipment faults after operator confirmation.

AN2121 Analytic 2121

Real-time monitoring identifies an Industrial Control System (ICS) Linux service process (historian daemon, Open Platform Communications (OPC) gateway) being killed or crashing following a sustained high-rate inbound connection pattern recorded by network monitoring, correlated with daemon log entries indicating connection limit exhaustion or out-of-memory conditions. OT operational-fidelity gate: Alert only when a device-specific traffic/resource threshold is exceeded and the same window shows service degradation, failed polling, device alarm/restart, resource exhaustion, or malformed/out-of-spec protocol behavior. Suppress planned load tests, maintenance, network convergence/failover, and known equipment faults after operator confirmation.

AN2168 Analytic 2168

Real-time monitoring of switch/router interface counters identifies a sudden spike in discarded or errored packets on an Industrial Control System (ICS)-facing interface combined with Central Processing Unit (CPU) utilization climbing above baseline, correlated with loss of reachability to downstream field devices on that segment within the same window. OT operational-fidelity gate: Alert only when a device-specific traffic/resource threshold is exceeded and the same window shows service degradation, failed polling, device alarm/restart, resource exhaustion, or malformed/out-of-spec protocol behavior. Suppress planned load tests, maintenance, network convergence/failover, and known equipment faults after operator confirmation.

AN2268 Analytic 2268

Real-time monitoring identifies an Industrial Control System (ICS) Windows service (Open Platform Communications (OPC) server, historian, Supervisory Control and Data Acquisition (SCADA) polling service) consuming abnormal Central Processing Unit (CPU)/memory resources and becoming unresponsive following receipt of a high volume of connections to its application port, correlated with watchdog timeout or service crash events. OT operational-fidelity gate: Alert only when a device-specific traffic/resource threshold is exceeded and the same window shows service degradation, failed polling, device alarm/restart, resource exhaustion, or malformed/out-of-spec protocol behavior. Suppress planned load tests, maintenance, network convergence/failover, and known equipment faults after operator confirmation.

Connected ecosystem references

Linked tags

Simulation, tools and telemetry

T0814 simulation workspace

No reviewed association in this snapshot.

Existing anomaly research

Original publication snapshot · Anomaly Detection Atlas

Complete technique engineering workbook

Collection configuration and event examples · Anomaly models and design worksheet · Tools and documented software · Simulation procedures · Offline synthetic collection check

Exact source tags are not semantic relevance verdicts. Review actual rule conditions and observation points; imported rules are not backend-compiled or live-validated.

Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.