1200kmSECURITY RESEARCH
Loading interactive filters…

1200KM / simulation

T1691.002 Reporting Message — Attack Simulation

Adversaries may block or prevent a reporting message from reaching its intended target. In control systems, reporting messages contain telemetry data (e.g., I/O values) pertaining to the current state of equipment and the industrial process. By blocking these reporting messages, an adversary can potentially hide their actions from an operator. Blocking reporting messages in control systems that manage physical processes may contribute to system…

Complete technique description

Adversaries may block or prevent a reporting message from reaching its intended target. In control systems, reporting messages contain telemetry data (e.g., I/O values) pertaining to the current state of equipment and the industrial process. By blocking these reporting messages, an adversary can potentially hide their actions from an operator.

Blocking reporting messages in control systems that manage physical processes may contribute to system impact, causing inhibition of a response function. A control system may not be able to respond in a proper or timely manner to an event, such as a dangerous fault, if its corresponding reporting message is blocked.[Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011][Electricity Information Sharing and Analysis Center; SANS Industrial Control Systems March 2016]

Official technique definition · Open in the interactive matrix

Parent and sub-techniques

Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.

Detection telemetry and configuration

These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.

Application Log Content · source-mapped

DC0038 collection page — Select the application event family required by the detection and document its native schema before normalization.

Providers and collection configuration

  • Enable the application audit category or instrument the owned lab application at the authorization/action boundary.
  • Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.
  • Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart.

Required normalized fields: service, action, actor, record_count, result.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0038",
  "collector": "illustrative-lab-collector",
  "observation": {
    "service": "lab-portal",
    "action": "export_requested",
    "actor": "lab-reader",
    "record_count": 3,
    "result": "authorized"
  }
}

Visibility limits: Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.

Network Traffic Flow · source-mapped

DC0078 collection page — Collect Zeek conn.log, Suricata flow events or exporter equivalents, including observation point and sampling settings.

Providers and collection configuration

  • Zeek: Connection and protocol metadata from traffic visible to the sensor.
  • Suricata EVE: Configured flow, alert, DNS, HTTP, TLS and protocol records.
  • AWS VPC Flow Logs: IP traffic metadata alternative; no packet payload or DNS answer history, and some traffic is not logged.
  • Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.
  • Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.
  • Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection.

Required normalized fields: source_ip, destination_ip, destination_port, protocol, bytes_sent, bytes_received.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0078",
  "collector": "illustrative-lab-collector",
  "observation": {
    "source_ip": "192.0.2.10",
    "destination_ip": "198.51.100.20",
    "destination_port": 443,
    "protocol": "tcp",
    "bytes_sent": 128,
    "bytes_received": 512
  }
}

Visibility limits: Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.

Process Creation · source-mapped

DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.

Providers and collection configuration

  • Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
  • Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
  • Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
  • On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
  • Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
  • For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.

Required normalized fields: process_guid, image, parent_image, command_line, user.

<EventFiltering>
  <ProcessCreate onmatch="include">
    <Image condition="is">C:\Windows\System32\whoami.exe</Image>
  </ProcessCreate>
</EventFiltering>

This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0032",
  "collector": "illustrative-lab-collector",
  "observation": {
    "process_guid": "lab-process-001",
    "image": "C:\\Windows\\System32\\whoami.exe",
    "parent_image": "C:\\Windows\\System32\\cmd.exe",
    "command_line": "whoami",
    "user": "LAB\\analyst"
  }
}

Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.

Process History/Live Data · source-mapped

DC0107 collection page — Export historian/process tags with engineering units, quality and source timestamps; define expected sample rate and compare an independent signal.

Providers and collection configuration

  • Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.
  • Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.
  • Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs.

Required normalized fields: tag, value, unit, quality.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0107",
  "collector": "illustrative-lab-collector",
  "observation": {
    "tag": "LAB.TankLevel",
    "value": 42,
    "unit": "percent",
    "quality": "good"
  }
}

Visibility limits: There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.

Detection rules and analytic guidance

Open the dedicated detection workspace · Existing query engineering

DET0789 Detection of Block Reporting Message

MITRE detection strategy

AN1921 Analytic 1921

Real-time monitoring identifies iptables/nftables rules on Industrial Control System (ICS) Linux gateways that selectively drop ICS reporting message traffic based on content while allowing command traffic to pass. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Linux.

  • Process Creation — auditd:SYSCALL; channel Linux Audit SYSCALL/EXECVE/SOCKADDR records (configured audit rule): syscall=execve; command line invokes iptables/nftables to change ICS traffic filtering or redirection outside the authorized network-administration baseline.

AN2198 Analytic 2198

Real-time monitoring identifies ACL modifications on Industrial Control System (ICS) network devices specifically blocking ICS reporting message ports while allowing command ports to remain open. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Network Devices.

  • Application Log Content — networkdevice:syslog; channel Access Control List (ACL) modification blocking Industrial Control Systems (ICS) reporting message ports while command ports remain open.

AN2216 Analytic 2216

Real-time monitoring identifies a field device ceasing to send expected unsolicited reports or periodic status updates without a corresponding device alarm or maintenance event, while the device remains reachable via direct polling. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Embedded.

  • Process History/Live Data — operationaldb:ProcessHistory; channel no unsolicited report received from device_ip within 1.5x expected reporting interval, while direct polling confirms device is reachable.
  • Network Traffic Flow — NSM:Connections; channel device_ip generates no outbound unsolicited traffic while responding normally to inbound polls.

AN2264 Analytic 2264

Real-time monitoring identifies Windows firewall changes blocking unsolicited Industrial Control System (ICS) reporting traffic while leaving polling/command traffic unaffected, resulting in Supervisory Control and Data Acquisition (SCADA) losing event-driven visibility while retaining polling capability. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Windows.

No structured log-source mapping supplied by this analytic.

Source rule directory and observation requirements

No exact-tagged Sigma source rule was imported. This does not establish that the technique is undetectable; the MITRE guidance and collection requirements remain relevant.

Before treating a rule as coverage

  1. Read the actual condition and logsource; identify attacker-side, victim-side or third-party visibility.
  2. Map native sensor fields, parse times and identities, then compile for the selected backend.
  3. Replay a behavior-positive case, a normal control, an authorized look-alike and a missing-telemetry case.
  4. Record matches and misses with rule version and source events. No match is inconclusive when required telemetry is absent.

Anomaly-based detection

No exact technique-specific Atlas model is present for T1691.002 in the selected source snapshot. The following is a design worksheet, not a newly validated model.

Anomaly engineering worksheet

Start from the exact analytic above. The collection-specific lenses below are analyst recommendations; they do not assert that an arbitrary statistical deviation detects this technique.

  • Application and service audit: Per application, client and route: request rate, rare actions, failure ratios and unusual state transitions. Version changes, retries, health probes and seasonal load need separate baselines.
  • Network and protocol telemetry: Per source and observation point: connection rate, destination-host/port fan-out, response/failure ratio and previously unseen destinations. Compare equivalent time windows; separate authorized scanners, NAT and sampling effects.
  • Endpoint activity: Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity.
  • Industrial operations and physical process: Per asset, operating mode and engineering change window: deviations in command/state sequences, measurement residuals and communication freshness. Use a simulator or approved test rig; never generate hazardous physical effects.
  1. Define an entity/peer group and feature; exclude the evaluation period from baseline training.
  2. Use representative normal and maintenance activity. Do not invent a production threshold from a synthetic example.
  3. Evaluate held-out behavior-positive and benign cases; measure false positives, misses and telemetry loss separately.
  4. Keep abnormality separate from maliciousness. Correlate with the behavior-specific source evidence.

Anomaly Detection Atlas · Baseline, validation and blind spots

Attack tools and documented software

No reviewed lab-tool association is selected for this exact technique. This is a curation gap, not a statement that no tool can implement the behavior.

Software observed in source procedures

These are exact ATT&CK software-use relationships, including malware. They provide behavior context, not recommendations to download or execute malware. No safety or detector claim is inherited.

1 source-documented software associations
  • S0604 Industroyer — malware.

    Industroyer uses the first COM port from the configuration file for the communication and the other two COM ports are opened to prevent other processes accessing them. This may block processes or operators from getting reporting messages from a device. [Anton Cherepanov, ESET June 2017]

    Exact relationship: relationship--605dcc44-9e1c-42a9-bc0f-5dfa81444022

Simulation design and documented procedures

Atomic evidence: no compatible candidate in this snapshot. Live lab status: not run for these imported procedures.

Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.

No compatible Atomic procedure is present in this pinned evidence set. Technical feasibility has not been ruled out. A custom procedure must define the behavior, target, collection point, success observable and rollback before execution.

Technique-specific experiment contract

  1. Choose one procedure implementing T1691.002 Reporting Message; identify the observable behavior in the source definition, not just its tactic.
  2. Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
  3. Enable the collection sources above and verify a benign baseline reaches the detector.
  4. Run only the approved isolated scenario; capture native events and an independent behavior observable.
  5. Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.

Synthetic logs and offline contract check

Download synthetic collection fixture (JSON) · Download the complete engineering workbook

This fixture exercises the listed collection fields. It does not reproduce Reporting Message, label its example events as malicious, or measure detection effectiveness. Use the exact analytic and selected procedure to build an independently labelled behavior-positive dataset.

Not run in this browser. No network scan or attack command is executed by this control.

Validation status and remaining work

Source identity
Joined by exact technique/object IDs against hash-pinned sources.
Collection fixture
Available for offline schema exercises; not attack emulation.
Native telemetry / backend / real attack
Not validated for these imported procedures. Source fidelity and page tests cannot establish sensor or detector effectiveness.

All-page audit and evidence inventory · This page’s machine-readable workbook

Sources and evidence boundaries

Pinned MITRE STIX source · SHA-256 c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183. Definition and procedure context are reproduced from this snapshot, not independently re-investigated incidents.

Source-linked mitigations
  • M0807 Network Allowlists

    Utilize network allowlists to restrict unnecessary connections to network devices (e.g., comm servers, serial to ethernet converters) and services, especially in cases when devices have limits on the number of simultaneous sessions they support.

  • M0810 Out-of-Band Communications Channel

    Provide an alternative method for sending critical report messages to operators, this could include using radio/cell communication to obtain messages from field technicians that can locally obtain telemetry and status data.

  • M0814 Static Network Configuration

    Unauthorized connections can be prevented by statically defining the hosts and ports used for automation protocol connections.

Connected ecosystem references

Linked tags

Detection and collection

T1691.002 detection workspace

No reviewed association in this snapshot.

Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.