T1691.001 Command Message — Attack Simulation

Adversaries may block a command message from reaching its intended target to prevent command execution. In OT networks, command messages are sent to provide instructions to control system devices. A blocked command message can inhibit response functions from correcting a disruption or unsafe condition.

Complete technique description

Adversaries may block a command message from reaching its intended target to prevent command execution. In OT networks, command messages are sent to provide instructions to control system devices. A blocked command message can inhibit response functions from correcting a disruption or unsafe condition.[Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011][Electricity Information Sharing and Analysis Center; SANS Industrial Control Systems March 2016]

Official technique definition · Open in the interactive matrix

Parent and sub-techniques

Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.

Detection telemetry and configuration

These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.

Application Log Content · source-mapped

DC0038 collection page — Select the application event family required by the detection and document its native schema before normalization.

Providers and collection configuration

  • Enable the application audit category or instrument the owned lab application at the authorization/action boundary.
  • Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.
  • Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart.

Required normalized fields: service, action, actor, record_count, result.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0038",
  "collector": "illustrative-lab-collector",
  "observation": {
    "service": "lab-portal",
    "action": "export_requested",
    "actor": "lab-reader",
    "record_count": 3,
    "result": "authorized"
  }
}

Visibility limits: Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.

Network Connection Creation · source-mapped

DC0082 collection page — Enable scoped Sysmon NetworkConnect (3), disabled by default, or a platform-equivalent process-aware network sensor.

Providers and collection configuration

  • Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
  • Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
  • Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
  • On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
  • Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
  • For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.

Required normalized fields: process_guid, destination_ip, destination_port, protocol, initiated.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0082",
  "collector": "illustrative-lab-collector",
  "observation": {
    "process_guid": "lab-process-001",
    "destination_ip": "198.51.100.20",
    "destination_port": 443,
    "protocol": "tcp",
    "initiated": true
  }
}

Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.

Network Traffic Flow · source-mapped

DC0078 collection page — Collect Zeek conn.log, Suricata flow events or exporter equivalents, including observation point and sampling settings.

Providers and collection configuration

  • Zeek: Connection and protocol metadata from traffic visible to the sensor.
  • Suricata EVE: Configured flow, alert, DNS, HTTP, TLS and protocol records.
  • AWS VPC Flow Logs: IP traffic metadata alternative; no packet payload or DNS answer history, and some traffic is not logged.
  • Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.
  • Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.
  • Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection.

Required normalized fields: source_ip, destination_ip, destination_port, protocol, bytes_sent, bytes_received.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0078",
  "collector": "illustrative-lab-collector",
  "observation": {
    "source_ip": "192.0.2.10",
    "destination_ip": "198.51.100.20",
    "destination_port": 443,
    "protocol": "tcp",
    "bytes_sent": 128,
    "bytes_received": 512
  }
}

Visibility limits: Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.

Process Creation · source-mapped

DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.

Providers and collection configuration

  • Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
  • Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
  • Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
  • On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
  • Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
  • For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.

Required normalized fields: process_guid, image, parent_image, command_line, user.

<EventFiltering>
  <ProcessCreate onmatch="include">
    <Image condition="is">C:\Windows\System32\whoami.exe</Image>
  </ProcessCreate>
</EventFiltering>

This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0032",
  "collector": "illustrative-lab-collector",
  "observation": {
    "process_guid": "lab-process-001",
    "image": "C:\\Windows\\System32\\whoami.exe",
    "parent_image": "C:\\Windows\\System32\\cmd.exe",
    "command_line": "whoami",
    "user": "LAB\\analyst"
  }
}

Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.

Process History/Live Data · source-mapped

DC0107 collection page — Export historian/process tags with engineering units, quality and source timestamps; define expected sample rate and compare an independent signal.

Providers and collection configuration

  • Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.
  • Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.
  • Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs.

Required normalized fields: tag, value, unit, quality.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0107",
  "collector": "illustrative-lab-collector",
  "observation": {
    "tag": "LAB.TankLevel",
    "value": 42,
    "unit": "percent",
    "quality": "good"
  }
}

Visibility limits: There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.

Detection rules and analytic guidance

Open the dedicated detection workspace · Existing query engineering

DET0784 Detection of Block Command Message

MITRE detection strategy

AN1916 Analytic 1916

Real-time monitoring identifies the absence of expected command-message delivery confirmation -- a Supervisory Control and Data Acquisition (SCADA)-issued command that does not produce the expected corresponding state-change response within the normal response latency window, while the device remains reachable for other traffic. Documented in the 2015 Ukraine attack, where Sandworm used malicious firmware to render serial-to-Ethernet converters inoperable. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Embedded.

  • Process History/Live Data — operationaldb:ProcessHistory; channel process value expected to change following a command does not change within command confirmation window.
  • Network Traffic Flow — NSM:Connections; channel command-type traffic to device_ip absent while other traffic types (polling, reporting) to the same device continue normally.
  • Application Log Content — scada:applog; channel command issued to device_ip with no corresponding state-change confirmation received within command confirmation window.

AN2118 Analytic 2118

Real-time monitoring identifies iptables/nftables rule additions on Industrial Control System (ICS) Linux gateways that filter ICS command messages based on content, while allowing other traffic to pass. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Linux.

  • Process Creation — auditd:SYSCALL; channel Linux Audit SYSCALL/EXECVE/SOCKADDR records (configured audit rule): syscall=execve; command line invokes iptables/nftables to change ICS traffic filtering or redirection outside the authorized network-administration baseline.

AN2263 Analytic 2263

Real-time monitoring identifies Windows host-based firewall rule modifications or network interface configuration changes on Industrial Control System (ICS) Windows servers that block ICS command-message traffic, coinciding with Supervisory Control and Data Acquisition (SCADA) showing communication loss to field devices. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Windows.

  • Network Connection Creation — WinEventLog:Security; channel EventCode=5157 or firewall rule changes blocking Industrial Control Systems (ICS) command message traffic.
Source rule directory and observation requirements

No exact-tagged Sigma source rule was imported. This does not establish that the technique is undetectable; the MITRE guidance and collection requirements remain relevant.

Before treating a rule as coverage

  1. Read the actual condition and logsource; identify attacker-side, victim-side or third-party visibility.
  2. Map native sensor fields, parse times and identities, then compile for the selected backend.
  3. Replay a behavior-positive case, a normal control, an authorized look-alike and a missing-telemetry case.
  4. Record matches and misses with rule version and source events. No match is inconclusive when required telemetry is absent.

Anomaly-based detection

No exact technique-specific Atlas model is present for T1691.001 in the selected source snapshot. The following is a design worksheet, not a newly validated model.

Anomaly engineering worksheet

Start from the exact analytic above. The collection-specific lenses below are analyst recommendations; they do not assert that an arbitrary statistical deviation detects this technique.

  • Application and service audit: Per application, client and route: request rate, rare actions, failure ratios and unusual state transitions. Version changes, retries, health probes and seasonal load need separate baselines.
  • Endpoint activity: Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity.
  • Network and protocol telemetry: Per source and observation point: connection rate, destination-host/port fan-out, response/failure ratio and previously unseen destinations. Compare equivalent time windows; separate authorized scanners, NAT and sampling effects.
  • Industrial operations and physical process: Per asset, operating mode and engineering change window: deviations in command/state sequences, measurement residuals and communication freshness. Use a simulator or approved test rig; never generate hazardous physical effects.
  1. Define an entity/peer group and feature; exclude the evaluation period from baseline training.
  2. Use representative normal and maintenance activity. Do not invent a production threshold from a synthetic example.
  3. Evaluate held-out behavior-positive and benign cases; measure false positives, misses and telemetry loss separately.
  4. Keep abnormality separate from maliciousness. Correlate with the behavior-specific source evidence.

Anomaly Detection Atlas · Baseline, validation and blind spots

Attack tools and documented software

No reviewed lab-tool association is selected for this exact technique. This is a curation gap, not a statement that no tool can implement the behavior.

Software observed in source procedures

These are exact ATT&CK software-use relationships, including malware. They provide behavior context, not recommendations to download or execute malware. No safety or detector claim is inherited.

1 source-documented software associations
  • S0604 Industroyer — malware.

    In Industroyer the first COM port from the configuration file is used for the actual communication and the two other COM ports are just opened to prevent other processes accessing them. Thus, the IEC 101 payload component is able to take over and maintain control of the RTU device. [Anton Cherepanov, ESET June 2017]

    Exact relationship: relationship--6ce3bd17-de4c-4ff3-9f7d-ae30efae2b58

Simulation design and documented procedures

Atomic evidence: no compatible candidate in this snapshot. Live lab status: not run for these imported procedures.

Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.

No compatible Atomic procedure is present in this pinned evidence set. Technical feasibility has not been ruled out. A custom procedure must define the behavior, target, collection point, success observable and rollback before execution.

Technique-specific experiment contract

  1. Choose one procedure implementing T1691.001 Command Message; identify the observable behavior in the source definition, not just its tactic.
  2. Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
  3. Enable the collection sources above and verify a benign baseline reaches the detector.
  4. Run only the approved isolated scenario; capture native events and an independent behavior observable.
  5. Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.

Synthetic logs and offline contract check

Download synthetic collection fixture (JSON) · Download the complete engineering workbook

This fixture exercises the listed collection fields. It does not reproduce Command Message, label its example events as malicious, or measure detection effectiveness. Use the exact analytic and selected procedure to build an independently labelled behavior-positive dataset.

Not run in this browser. No network scan or attack command is executed by this control.

Validation status and remaining work

Source identity
Joined by exact technique/object IDs against hash-pinned sources.
Collection fixture
Available for offline schema exercises; not attack emulation.
Native telemetry / backend / real attack
Not validated for these imported procedures. Source fidelity and page tests cannot establish sensor or detector effectiveness.

All-page audit and evidence inventory · This page’s machine-readable workbook

Sources and evidence boundaries

Pinned MITRE STIX source · SHA-256 c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183. Definition and procedure context are reproduced from this snapshot, not independently re-investigated incidents.

Source-linked mitigations
  • M0807 Network Allowlists

    Utilize network allowlists to restrict unnecessary connections to network devices (e.g., comm servers, serial to ethernet converters) and services, especially in cases when devices have limits on the number of simultaneous sessions they support.

  • M0810 Out-of-Band Communications Channel

    Provide an alternative method for sending critical command messages to outstations, this could include using radio/cell communication to send messages to a field technician that physically performs the control function.

  • M0814 Static Network Configuration

    Unauthorized connections can be prevented by statically defining the hosts and ports used for automation protocol connections.

Connected ecosystem references

Linked tags

Detection and collection

T1691.001 detection workspace

No reviewed association in this snapshot.

Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.