Adversaries may manipulate the I/O image of PLCs through various means to prevent them from functioning as expected. Methods of I/O image manipulation may include overriding the I/O table via direct memory manipulation or using the override function used for testing PLC programs. During the scan cycle, a PLC reads the status of all inputs and stores them in an image table. The image table is the PLCs internal storage location where values of…

Complete technique description

Adversaries may manipulate the I/O image of PLCs through various means to prevent them from functioning as expected. Methods of I/O image manipulation may include overriding the I/O table via direct memory manipulation or using the override function used for testing PLC programs. [Dr. Kelvin T. Erickson December 2010] During the scan cycle, a PLC reads the status of all inputs and stores them in an image table. [Nanjundaiah, Vaidyanath] The image table is the PLCs internal storage location where values of inputs/outputs for one scan are stored while it executes the user program. After the PLC has solved the entire logic program, it updates the output image table. The contents of this output image table are written to the corresponding output points in I/O Modules.

One of the unique characteristics of PLCs is their ability to override the status of a physical discrete input or to override the logic driving a physical output coil and force the output to a desired status.

Official technique definition · Open in the interactive matrix

Detection telemetry and configuration

These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.

Network Traffic Flow · source-mapped

DC0078 collection page — Collect Zeek conn.log, Suricata flow events or exporter equivalents, including observation point and sampling settings.

Providers and collection configuration

  • Zeek: Connection and protocol metadata from traffic visible to the sensor.
  • Suricata EVE: Configured flow, alert, DNS, HTTP, TLS and protocol records.
  • AWS VPC Flow Logs: IP traffic metadata alternative; no packet payload or DNS answer history, and some traffic is not logged.
  • Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.
  • Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.
  • Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection.

Required normalized fields: source_ip, destination_ip, destination_port, protocol, bytes_sent, bytes_received.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0078",
  "collector": "illustrative-lab-collector",
  "observation": {
    "source_ip": "192.0.2.10",
    "destination_ip": "198.51.100.20",
    "destination_port": 443,
    "protocol": "tcp",
    "bytes_sent": 128,
    "bytes_received": 512
  }
}

Visibility limits: Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.

Process History/Live Data · source-mapped

DC0107 collection page — Export historian/process tags with engineering units, quality and source timestamps; define expected sample rate and compare an independent signal.

Providers and collection configuration

  • Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.
  • Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.
  • Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs.

Required normalized fields: tag, value, unit, quality.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0107",
  "collector": "illustrative-lab-collector",
  "observation": {
    "tag": "LAB.TankLevel",
    "value": 42,
    "unit": "percent",
    "quality": "good"
  }
}

Visibility limits: There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.

Detection rules and analytic guidance

Open the dedicated detection workspace · Existing query engineering

DET0773 Detection of Manipulate I/O Image

MITRE detection strategy

AN1905 Analytic 1905

Real-time monitoring identifies an Industrial Control System (ICS) protocol write to output register addresses on a field device from a source not in the approved write-source list, correlated with a discrepancy between the value reported by the Input/Output (I/O) image and an independent measurement of the actual physical output state. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures. The independent measurement is process-state telemetry, not network-flow evidence; implementation requires a separately trusted sensor/historian/measurement path with time alignment and an engineering-defined tolerance.

Platforms: Embedded.

  • Network Traffic Flow — NSM:Content; channel write function code to output register address range from source not in approved write sources.
  • Process History/Live Data — processsensor:RedundantComparison; channel Independent process measurement comparison: controller I/O image value diverges from independent sensor/measurement beyond configured integrity tolerance.
Source rule directory and observation requirements

No exact-tagged Sigma source rule was imported. This does not establish that the technique is undetectable; the MITRE guidance and collection requirements remain relevant.

Before treating a rule as coverage

  1. Read the actual condition and logsource; identify attacker-side, victim-side or third-party visibility.
  2. Map native sensor fields, parse times and identities, then compile for the selected backend.
  3. Replay a behavior-positive case, a normal control, an authorized look-alike and a missing-telemetry case.
  4. Record matches and misses with rule version and source events. No match is inconclusive when required telemetry is absent.

Anomaly-based detection

No exact technique-specific Atlas model is present for T0835 in the selected source snapshot. The following is a design worksheet, not a newly validated model.

Anomaly engineering worksheet

Start from the exact analytic above. The collection-specific lenses below are analyst recommendations; they do not assert that an arbitrary statistical deviation detects this technique.

  • Network and protocol telemetry: Per source and observation point: connection rate, destination-host/port fan-out, response/failure ratio and previously unseen destinations. Compare equivalent time windows; separate authorized scanners, NAT and sampling effects.
  • Industrial operations and physical process: Per asset, operating mode and engineering change window: deviations in command/state sequences, measurement residuals and communication freshness. Use a simulator or approved test rig; never generate hazardous physical effects.
  1. Define an entity/peer group and feature; exclude the evaluation period from baseline training.
  2. Use representative normal and maintenance activity. Do not invent a production threshold from a synthetic example.
  3. Evaluate held-out behavior-positive and benign cases; measure false positives, misses and telemetry loss separately.
  4. Keep abnormality separate from maliciousness. Correlate with the behavior-specific source evidence.

Anomaly Detection Atlas · Baseline, validation and blind spots

Attack tools and documented software

No reviewed lab-tool association is selected for this exact technique. This is a curation gap, not a statement that no tool can implement the behavior.

Software observed in source procedures

These are exact ATT&CK software-use relationships, including malware. They provide behavior context, not recommendations to download or execute malware. No safety or detector claim is inherited.

2 source-documented software associations

Simulation design and documented procedures

Atomic evidence: no compatible candidate in this snapshot. Live lab status: not run for these imported procedures.

Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.

No compatible Atomic procedure is present in this pinned evidence set. Technical feasibility has not been ruled out. A custom procedure must define the behavior, target, collection point, success observable and rollback before execution.

Technique-specific experiment contract

  1. Choose one procedure implementing T0835 Manipulate I/O Image; identify the observable behavior in the source definition, not just its tactic.
  2. Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
  3. Enable the collection sources above and verify a benign baseline reaches the detector.
  4. Run only the approved isolated scenario; capture native events and an independent behavior observable.
  5. Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.

Synthetic logs and offline contract check

Download synthetic collection fixture (JSON) · Download the complete engineering workbook

This fixture exercises the listed collection fields. It does not reproduce Manipulate I/O Image, label its example events as malicious, or measure detection effectiveness. Use the exact analytic and selected procedure to build an independently labelled behavior-positive dataset.

Not run in this browser. No network scan or attack command is executed by this control.

Validation status and remaining work

Source identity
Joined by exact technique/object IDs against hash-pinned sources.
Collection fixture
Available for offline schema exercises; not attack emulation.
Native telemetry / backend / real attack
Not validated for these imported procedures. Source fidelity and page tests cannot establish sensor or detector effectiveness.

All-page audit and evidence inventory · This page’s machine-readable workbook

Sources and evidence boundaries

Pinned MITRE STIX source · SHA-256 c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183. Definition and procedure context are reproduced from this snapshot, not independently re-investigated incidents.

Source-linked mitigations

Connected ecosystem references

Linked tags

Detection and collection

T0835 detection workspace

No reviewed association in this snapshot.

Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.