1200KM / telemetry
Process Termination — Detection Telemetry
Termination of a process, correlated to its earlier creation.
Collection and providers
Collect Sysmon ProcessTerminate (5) and join on ProcessGuid; do not assume every provider records an exit code.
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
Configuration
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Synthetic event example
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0033",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"process_id": 4200,
"action": "terminate"
}
}Visibility and validation
Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
- Record the lab scope, collector version, effective configuration and expected source fields before testing.
- Use an approved benign action or read-only snapshot appropriate to this type. For destructive, privileged or physical effects, use a reviewed fixture or existing authorized evidence instead of causing the effect.
- Verify the native source record locally and at the collector; compare timestamps, identity, object, action/result and the type-specific fields listed below. Save a redacted real capture separately from the synthetic example.
- Check a normal baseline and collector-loss case. Fixture parsing proves parser behavior only; it does not prove sensor coverage or malicious-behavior detection.
Primary sources
Connected ecosystem references
Linked tags
Related simulations and detection workspaces
Each workspace retains its own logsource and platform requirements. A technique-level association is not a per-rule sensor mapping.
- T1480.002 · Mutual Exclusion · Detection rules & anomalies
- T1485 · Data Destruction · Detection rules & anomalies
- T1489 · Service Stop · Detection rules & anomalies
- T1499.004 · Application or System Exploitation · Detection rules & anomalies
- T1548.003 · Sudo and Sudo Caching · Detection rules & anomalies
- T1668 · Exclusive Control · Detection rules & anomalies
- T1685 · Disable or Modify Tools · Detection rules & anomalies
- T0814 · Denial of Service · Detection rules & anomalies
Attack tools through shared TTPs
These are two-hop navigation links through explicitly associated techniques, not independent tool-to-sensor assertions.
Native security log sources
Security log-source library groups concrete producers and formats separately from ATT&CK data components. Samples carry provenance and version limits; associations do not prove collection coverage.
Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.