1200kmSECURITY RESEARCH
Loading interactive filters…

1200KM / simulation

T1695.002 Ethernet — Attack Simulation

Adversaries may block access to Ethernet communications to prevent instructions or configurations messages from reaching target systems and devices. Ethernet connections allow for communications between IT and OT systems and devices. Blocking Ethernet communications may also block command and reporting messages. An adversary may block Ethernet communications by disabling network interfaces, Service Stop, or conducting an Adversary-in-the-Middle…

Complete technique description

Adversaries may block access to Ethernet communications to prevent instructions or configurations messages from reaching target systems and devices. Ethernet connections allow for communications between IT and OT systems and devices. Blocking Ethernet communications may also block command and reporting messages.[Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011]

An adversary may block Ethernet communications by disabling network interfaces, Service Stop, or conducting an Adversary-in-the-Middle attack and dropping the network traffic.

Official technique definition · Open in the interactive matrix

Parent and sub-techniques

Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.

Detection telemetry and configuration

These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.

Application Log Content · source-mapped

DC0038 collection page — Select the application event family required by the detection and document its native schema before normalization.

Providers and collection configuration

  • Enable the application audit category or instrument the owned lab application at the authorization/action boundary.
  • Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.
  • Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart.

Required normalized fields: service, action, actor, record_count, result.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0038",
  "collector": "illustrative-lab-collector",
  "observation": {
    "service": "lab-portal",
    "action": "export_requested",
    "actor": "lab-reader",
    "record_count": 3,
    "result": "authorized"
  }
}

Visibility limits: Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.

Device Alarm · source-mapped

DC0108 collection page — Subscribe to supported device alarm/audit channels; retain code, severity, source asset and acknowledgement/clear times.

Providers and collection configuration

  • Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.
  • Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.
  • Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs.

Required normalized fields: asset_id, alarm_code, severity, active.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0108",
  "collector": "illustrative-lab-collector",
  "observation": {
    "asset_id": "lab-controller-1",
    "alarm_code": "LAB_COMM_LOSS",
    "severity": "warning",
    "active": true
  }
}

Visibility limits: There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.

Process Creation · source-mapped

DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.

Providers and collection configuration

  • Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
  • Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
  • Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
  • On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
  • Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
  • For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.

Required normalized fields: process_guid, image, parent_image, command_line, user.

<EventFiltering>
  <ProcessCreate onmatch="include">
    <Image condition="is">C:\Windows\System32\whoami.exe</Image>
  </ProcessCreate>
</EventFiltering>

This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0032",
  "collector": "illustrative-lab-collector",
  "observation": {
    "process_guid": "lab-process-001",
    "image": "C:\\Windows\\System32\\whoami.exe",
    "parent_image": "C:\\Windows\\System32\\cmd.exe",
    "command_line": "whoami",
    "user": "LAB\\analyst"
  }
}

Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.

Detection rules and analytic guidance

Open the dedicated detection workspace · Existing query engineering

DET0911 Detection of Block Ethernet

MITRE detection strategy

AN2054 Analytic 2054

Real-time monitoring identifies a Windows network-adapter disable or administrative interface-down event on an ICS gateway or protocol-converter host outside the approved network-maintenance window. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Windows.

  • Application Log Content — WinEventLog:System; channel network adapter disabled on Industrial Control Systems (ICS) gateway host by process not in authorized network admins.

AN2165 Analytic 2165

Real-time monitoring identifies ip link set down commands on Industrial Control System (ICS) Linux gateway hosts by a User Identifier (UID) not in the authorized net admin UIDs, affecting the device subnet interface. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Linux.

  • Process Creation — auditd:SYSCALL; channel Linux Audit SYSCALL/EXECVE/SOCKADDR records (configured audit rule): syscall=execve; ip link command disables an interface on an ICS gateway outside the authorized network-administration baseline.

AN2204 Analytic 2204

Real-time monitoring identifies a switch interface transitioning to administratively-down state on a port connected to an Industrial Control System (ICS) field device, from a configuration change source not in the approved network administration list. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Network Devices.

  • Application Log Content — networkdevice:syslog; channel interface shutdown command on Industrial Control Systems (ICS) device port from source not in approved Network Management System (NMS) Classless Inter-Domain Routing (CIDR) subnet outside change control window.

AN2214 Analytic 2214

Real-time monitoring identifies device_ip offline alarm coinciding with switch port admin-down syslog for that port, distinguishing deliberate Ethernet blocking from physical disconnection. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.

Platforms: Embedded.

  • Device Alarm — operationaldb:AlarmEvent; channel device offline alarm coinciding with switch port admin-down syslog for that port.
Source rule directory and observation requirements

No exact-tagged Sigma source rule was imported. This does not establish that the technique is undetectable; the MITRE guidance and collection requirements remain relevant.

Before treating a rule as coverage

  1. Read the actual condition and logsource; identify attacker-side, victim-side or third-party visibility.
  2. Map native sensor fields, parse times and identities, then compile for the selected backend.
  3. Replay a behavior-positive case, a normal control, an authorized look-alike and a missing-telemetry case.
  4. Record matches and misses with rule version and source events. No match is inconclusive when required telemetry is absent.

Anomaly-based detection

No exact technique-specific Atlas model is present for T1695.002 in the selected source snapshot. The following is a design worksheet, not a newly validated model.

Anomaly engineering worksheet

Start from the exact analytic above. The collection-specific lenses below are analyst recommendations; they do not assert that an arbitrary statistical deviation detects this technique.

  • Application and service audit: Per application, client and route: request rate, rare actions, failure ratios and unusual state transitions. Version changes, retries, health probes and seasonal load need separate baselines.
  • Industrial operations and physical process: Per asset, operating mode and engineering change window: deviations in command/state sequences, measurement residuals and communication freshness. Use a simulator or approved test rig; never generate hazardous physical effects.
  • Endpoint activity: Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity.
  1. Define an entity/peer group and feature; exclude the evaluation period from baseline training.
  2. Use representative normal and maintenance activity. Do not invent a production threshold from a synthetic example.
  3. Evaluate held-out behavior-positive and benign cases; measure false positives, misses and telemetry loss separately.
  4. Keep abnormality separate from maliciousness. Correlate with the behavior-specific source evidence.

Anomaly Detection Atlas · Baseline, validation and blind spots

Attack tools and documented software

No reviewed lab-tool association is selected for this exact technique. This is a curation gap, not a statement that no tool can implement the behavior.

Software observed in source procedures

These are exact ATT&CK software-use relationships, including malware. They provide behavior context, not recommendations to download or execute malware. No safety or detector claim is inherited.

1 source-documented software associations

Simulation design and documented procedures

Atomic evidence: no compatible candidate in this snapshot. Live lab status: not run for these imported procedures.

Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.

No compatible Atomic procedure is present in this pinned evidence set. Technical feasibility has not been ruled out. A custom procedure must define the behavior, target, collection point, success observable and rollback before execution.

Technique-specific experiment contract

  1. Choose one procedure implementing T1695.002 Ethernet; identify the observable behavior in the source definition, not just its tactic.
  2. Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
  3. Enable the collection sources above and verify a benign baseline reaches the detector.
  4. Run only the approved isolated scenario; capture native events and an independent behavior observable.
  5. Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.

Synthetic logs and offline contract check

Download synthetic collection fixture (JSON) · Download the complete engineering workbook

This fixture exercises the listed collection fields. It does not reproduce Ethernet, label its example events as malicious, or measure detection effectiveness. Use the exact analytic and selected procedure to build an independently labelled behavior-positive dataset.

Not run in this browser. No network scan or attack command is executed by this control.

Validation status and remaining work

Source identity
Joined by exact technique/object IDs against hash-pinned sources.
Collection fixture
Available for offline schema exercises; not attack emulation.
Native telemetry / backend / real attack
Not validated for these imported procedures. Source fidelity and page tests cannot establish sensor or detector effectiveness.

All-page audit and evidence inventory · This page’s machine-readable workbook

Sources and evidence boundaries

Pinned MITRE STIX source · SHA-256 c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183. Definition and procedure context are reproduced from this snapshot, not independently re-investigated incidents.

Source-linked mitigations

Connected ecosystem references

Linked tags

Detection and collection

T1695.002 detection workspace

No reviewed association in this snapshot.

Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.