Complete technique description
Adversaries may block access to serial COM to prevent instructions or configurations from reaching target devices. Serial Communication ports (COM) allow communication with control system devices. Devices can receive command and configuration messages over such serial COM. Devices also use serial COM to send command and reporting messages. Blocking device serial COM may also block command messages and block reporting messages.
A serial to Ethernet converter is often connected to a serial COM to facilitate communication between serial and Ethernet devices. One approach to blocking a serial COM would be to create and hold open a TCP session with the Ethernet side of the converter. A serial to Ethernet converter may have a few ports open to facilitate multiple communications. For example, if there are three serial COM available -- 1, 2 and 3 --, the converter might be listening on the corresponding ports 20001, 20002, and 20003. If a TCP/IP connection is opened with one of these ports and held open, then the port will be unavailable for use by another party. One way the adversary could achieve this would be to initiate a TCP session with the serial to Ethernet converter at 10.0.0.1 via Telnet on serial port 1 with the following command: telnet 10.0.0.1 20001.
Official technique definition · Open in the interactive matrix
Parent and sub-techniques
Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.
Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
Application Log Content · source-mapped
DC0038 collection page — Select the application event family required by the detection and document its native schema before normalization.
Providers and collection configuration
- Enable the application audit category or instrument the owned lab application at the authorization/action boundary.
- Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.
- Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart.
Required normalized fields: service, action, actor, record_count, result.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0038",
"collector": "illustrative-lab-collector",
"observation": {
"service": "lab-portal",
"action": "export_requested",
"actor": "lab-reader",
"record_count": 3,
"result": "authorized"
}
}
Visibility limits: Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.
File Modification · source-mapped
DC0061 collection page — Use file-integrity monitoring or scoped OS file-write auditing for general changes. Sysmon 2 records creation-time changes; it is not a general file-write event.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: path, attribute, before, after.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0061",
"collector": "illustrative-lab-collector",
"observation": {
"path": "C:\\Lab\\demo.txt",
"attribute": "content_hash",
"before": "aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa",
"after": "bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Process/Event Alarm · source-mapped
DC0109 collection page — Export alarm/event history with setpoint context and lifecycle transitions; retain suppressed/shelved state when provided.
Providers and collection configuration
- Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.
- Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.
- Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs.
Required normalized fields: tag, alarm, threshold, value, acknowledged.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0109",
"collector": "illustrative-lab-collector",
"observation": {
"tag": "LAB.TankLevel",
"alarm": "high_level",
"threshold": 80,
"value": 82,
"acknowledged": false
}
}
Visibility limits: There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.
Windows Registry Key Modification · source-mapped
DC0063 collection page — Use RegistryEvent 13 for value-set and 14 for rename; compare against intended policy and keep original type/value where available.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- Keep this Windows-specific source separate from other operating systems; there is no direct cross-platform event-ID equivalence.
Required normalized fields: registry_path, event_type, value_type, value.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0063",
"collector": "illustrative-lab-collector",
"observation": {
"registry_path": "HKCU\\Software\\Lab\\Mode",
"event_type": "SetValue",
"value_type": "DWORD",
"value": 1
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Simulation design and documented procedures
Atomic evidence: no compatible candidate in this snapshot. Live lab status: not run for these imported procedures.
Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.
No compatible Atomic procedure is present in this pinned evidence set. Technical feasibility has not been ruled out. A custom procedure must define the behavior, target, collection point, success observable and rollback before execution.
Technique-specific experiment contract
- Choose one procedure implementing T1695.001 Serial COM; identify the observable behavior in the source definition, not just its tactic.
- Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
- Enable the collection sources above and verify a benign baseline reaches the detector.
- Run only the approved isolated scenario; capture native events and an independent behavior observable.
- Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.