1200kmSECURITY RESEARCH
Loading interactive filters…

1200KM / simulation

T0801 Monitor Process State — Attack Simulation

Adversaries may gather information about the physical process state. This information may be used to gain more information about the process itself or used as a trigger for malicious actions. The sources of process state information may vary such as, OPC tags, historian data, specific PLC block information, or network traffic.

Complete technique description

Adversaries may gather information about the physical process state. This information may be used to gain more information about the process itself or used as a trigger for malicious actions. The sources of process state information may vary such as, OPC tags, historian data, specific PLC block information, or network traffic.

Official technique definition · Open in the interactive matrix

Detection telemetry and configuration

These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.

Application Log Content · source-mapped

DC0038 collection page — Select the application event family required by the detection and document its native schema before normalization.

Providers and collection configuration

  • Enable the application audit category or instrument the owned lab application at the authorization/action boundary.
  • Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.
  • Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart.

Required normalized fields: service, action, actor, record_count, result.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0038",
  "collector": "illustrative-lab-collector",
  "observation": {
    "service": "lab-portal",
    "action": "export_requested",
    "actor": "lab-reader",
    "record_count": 3,
    "result": "authorized"
  }
}

Visibility limits: Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.

Network Connection Creation · source-mapped

DC0082 collection page — Enable scoped Sysmon NetworkConnect (3), disabled by default, or a platform-equivalent process-aware network sensor.

Providers and collection configuration

  • Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
  • Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
  • Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
  • On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
  • Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
  • For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.

Required normalized fields: process_guid, destination_ip, destination_port, protocol, initiated.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0082",
  "collector": "illustrative-lab-collector",
  "observation": {
    "process_guid": "lab-process-001",
    "destination_ip": "198.51.100.20",
    "destination_port": 443,
    "protocol": "tcp",
    "initiated": true
  }
}

Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.

Network Traffic Content · source-mapped

DC0085 collection page — Scope approved packet capture/protocol content collection to the lab flow; retain capture provenance and truncation indicators.

Providers and collection configuration

  • Zeek: Connection and protocol metadata from traffic visible to the sensor.
  • Suricata EVE: Configured flow, alert, DNS, HTTP, TLS and protocol records.
  • Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.
  • Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.
  • Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection.

Required normalized fields: flow_id, protocol, method, path, payload_excerpt.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0085",
  "collector": "illustrative-lab-collector",
  "observation": {
    "flow_id": "lab-flow-1",
    "protocol": "http",
    "method": "GET",
    "path": "/lab-check",
    "payload_excerpt": "LAB_TELEMETRY_CHECK"
  }
}

Visibility limits: Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.

Network Traffic Flow · source-mapped

DC0078 collection page — Collect Zeek conn.log, Suricata flow events or exporter equivalents, including observation point and sampling settings.

Providers and collection configuration

  • Zeek: Connection and protocol metadata from traffic visible to the sensor.
  • Suricata EVE: Configured flow, alert, DNS, HTTP, TLS and protocol records.
  • AWS VPC Flow Logs: IP traffic metadata alternative; no packet payload or DNS answer history, and some traffic is not logged.
  • Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.
  • Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.
  • Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection.

Required normalized fields: source_ip, destination_ip, destination_port, protocol, bytes_sent, bytes_received.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0078",
  "collector": "illustrative-lab-collector",
  "observation": {
    "source_ip": "192.0.2.10",
    "destination_ip": "198.51.100.20",
    "destination_port": 443,
    "protocol": "tcp",
    "bytes_sent": 128,
    "bytes_received": 512
  }
}

Visibility limits: Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.

Detection rules and analytic guidance

Open the dedicated detection workspace · Existing query engineering

DET0727 Detection of Monitor Process State

MITRE detection strategy

AN1860 Analytic 1860

Real-time network monitoring identifies a source issuing read-only Industrial Control System (ICS) protocol requests to multiple field devices at a polling rate exceeding the legitimate Supervisory Control and Data Acquisition (SCADA) baseline, from a source not in the approved control server allowlist. Because the action is read-only, source-identity and rate deviation are the only available distinguishing signals. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.

Platforms: Embedded.

  • Application Log Content — opc:applog; channel client_id not in approved Open Platform Communications (OPC) clients issuing high-volume read requests.
  • Network Traffic Content — NSM:Content; channel read-only function codes from source not in approved Supervisory Control and Data Acquisition (SCADA) servers at rate exceeding baseline poll rate or covering address ranges outside known tag ranges.

AN2125 Analytic 2125

Real-time monitoring identifies a scripting interpreter or custom binary on an Industrial Control System (ICS) Linux asset making sustained, high-frequency Industrial Control System (ICS) protocol read connections to field device IPs, from a User Identifier (UID) not associated with the recognized historian or Supervisory Control and Data Acquisition (SCADA) service account. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.

Platforms: Linux.

  • Network Connection Creation — auditd:SYSCALL; channel Linux Audit SYSCALL/EXECVE/SOCKADDR records (configured audit rule): execve of scripting interpreter with sustained network connect() calls to device subnet at rate exceeding poll baseline, by User Identifier (UID) not in service account allowlist.

AN2169 Analytic 2169

Real-time monitoring identifies NetFlow showing a host generating an anomalously high volume of short-duration flows to multiple field device IPs at regular intervals, from a source not in the approved Supervisory Control and Data Acquisition (SCADA) server list. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.

Platforms: Network Devices.

  • Network Traffic Flow — netflow:ipfix; channel IPFIX/NetFlow flow record (src/dst IP, src/dst port, protocol, packets/bytes/time): source not in approved Supervisory Control and Data Acquisition (SCADA) servers generating high volume of short-duration flows to device subnet at regular intervals.

AN2206 Analytic 2206

Real-time monitoring identifies a process on an Industrial Control System (ICS) Windows host querying device operating state or process values via vendor Application Programming Interfaces (APIs) at a frequency or scope exceeding documented Human-Machine Interface (HMI) refresh behavior, from a process not in the recognized HMI/Supervisory Control and Data Acquisition (SCADA) application list. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.

Platforms: Windows.

  • Application Log Content — opc:applog; channel Open Platform Communications (OPC) client polling frequency for tag set exceeds documented Human-Machine Interface (HMI) refresh baseline from client not in approved application list.
Source rule directory and observation requirements

No exact-tagged Sigma source rule was imported. This does not establish that the technique is undetectable; the MITRE guidance and collection requirements remain relevant.

Before treating a rule as coverage

  1. Read the actual condition and logsource; identify attacker-side, victim-side or third-party visibility.
  2. Map native sensor fields, parse times and identities, then compile for the selected backend.
  3. Replay a behavior-positive case, a normal control, an authorized look-alike and a missing-telemetry case.
  4. Record matches and misses with rule version and source events. No match is inconclusive when required telemetry is absent.

Anomaly-based detection

No exact technique-specific Atlas model is present for T0801 in the selected source snapshot. The following is a design worksheet, not a newly validated model.

Anomaly engineering worksheet

Start from the exact analytic above. The collection-specific lenses below are analyst recommendations; they do not assert that an arbitrary statistical deviation detects this technique.

  • Application and service audit: Per application, client and route: request rate, rare actions, failure ratios and unusual state transitions. Version changes, retries, health probes and seasonal load need separate baselines.
  • Endpoint activity: Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity.
  • Network and protocol telemetry: Per source and observation point: connection rate, destination-host/port fan-out, response/failure ratio and previously unseen destinations. Compare equivalent time windows; separate authorized scanners, NAT and sampling effects.
  1. Define an entity/peer group and feature; exclude the evaluation period from baseline training.
  2. Use representative normal and maintenance activity. Do not invent a production threshold from a synthetic example.
  3. Evaluate held-out behavior-positive and benign cases; measure false positives, misses and telemetry loss separately.
  4. Keep abnormality separate from maliciousness. Correlate with the behavior-specific source evidence.

Anomaly Detection Atlas · Baseline, validation and blind spots

Attack tools and documented software

No reviewed lab-tool association is selected for this exact technique. This is a curation gap, not a statement that no tool can implement the behavior.

Software observed in source procedures

These are exact ATT&CK software-use relationships, including malware. They provide behavior context, not recommendations to download or execute malware. No safety or detector claim is inherited.

4 source-documented software associations

Simulation design and documented procedures

Atomic evidence: no compatible candidate in this snapshot. Live lab status: not run for these imported procedures.

Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.

No compatible Atomic procedure is present in this pinned evidence set. Technical feasibility has not been ruled out. A custom procedure must define the behavior, target, collection point, success observable and rollback before execution.

Technique-specific experiment contract

  1. Choose one procedure implementing T0801 Monitor Process State; identify the observable behavior in the source definition, not just its tactic.
  2. Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
  3. Enable the collection sources above and verify a benign baseline reaches the detector.
  4. Run only the approved isolated scenario; capture native events and an independent behavior observable.
  5. Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.

Synthetic logs and offline contract check

Download synthetic collection fixture (JSON) · Download the complete engineering workbook

This fixture exercises the listed collection fields. It does not reproduce Monitor Process State, label its example events as malicious, or measure detection effectiveness. Use the exact analytic and selected procedure to build an independently labelled behavior-positive dataset.

Not run in this browser. No network scan or attack command is executed by this control.

Validation status and remaining work

Source identity
Joined by exact technique/object IDs against hash-pinned sources.
Collection fixture
Available for offline schema exercises; not attack emulation.
Native telemetry / backend / real attack
Not validated for these imported procedures. Source fidelity and page tests cannot establish sensor or detector effectiveness.

All-page audit and evidence inventory · This page’s machine-readable workbook

Sources and evidence boundaries

Pinned MITRE STIX source · SHA-256 c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183. Definition and procedure context are reproduced from this snapshot, not independently re-investigated incidents.

Source-linked mitigations

Connected ecosystem references

Linked tags

Detection and collection

T0801 detection workspace

No reviewed association in this snapshot.

Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.