1200KM / detection
T0801 Monitor Process State — Detection Rules
Detection workspace for T0801 Monitor Process State: 0 Sigma sources, 0 Atlas concepts and 0 anomaly models. No live detection validation.
Source-backed rule directory
No reviewed association in this snapshot.
Atlas deterministic concepts
No exact concept selected.
Anomaly models
No exact Atlas model in this snapshot.
ATT&CK analytic guidance
DET0727 Detection of Monitor Process State
AN1860 Analytic 1860
Real-time network monitoring identifies a source issuing read-only Industrial Control System (ICS) protocol requests to multiple field devices at a polling rate exceeding the legitimate Supervisory Control and Data Acquisition (SCADA) baseline, from a source not in the approved control server allowlist. Because the action is read-only, source-identity and rate deviation are the only available distinguishing signals. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
AN2125 Analytic 2125
Real-time monitoring identifies a scripting interpreter or custom binary on an Industrial Control System (ICS) Linux asset making sustained, high-frequency Industrial Control System (ICS) protocol read connections to field device IPs, from a User Identifier (UID) not associated with the recognized historian or Supervisory Control and Data Acquisition (SCADA) service account. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
AN2169 Analytic 2169
Real-time monitoring identifies NetFlow showing a host generating an anomalously high volume of short-duration flows to multiple field device IPs at regular intervals, from a source not in the approved Supervisory Control and Data Acquisition (SCADA) server list. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
AN2206 Analytic 2206
Real-time monitoring identifies a process on an Industrial Control System (ICS) Windows host querying device operating state or process values via vendor Application Programming Interfaces (APIs) at a frequency or scope exceeding documented Human-Machine Interface (HMI) refresh behavior, from a process not in the recognized HMI/Supervisory Control and Data Acquisition (SCADA) application list. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
Connected ecosystem references
Linked tags
Simulation, tools and telemetry
- Application Log Content · DC0038
- Network Connection Creation · DC0082
- Network Traffic Content · DC0085
- Network Traffic Flow · DC0078
No reviewed association in this snapshot.
Existing anomaly research
Complete technique engineering workbook
Collection configuration and event examples · Anomaly models and design worksheet · Tools and documented software · Simulation procedures · Offline synthetic collection check
Exact source tags are not semantic relevance verdicts. Review actual rule conditions and observation points; imported rules are not backend-compiled or live-validated.