Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
Application Log Content · source-mapped
DC0038 collection page — Select the application event family required by the detection and document its native schema before normalization.
Providers and collection configuration
- Enable the application audit category or instrument the owned lab application at the authorization/action boundary.
- Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.
- Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart.
Required normalized fields: service, action, actor, record_count, result.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0038",
"collector": "illustrative-lab-collector",
"observation": {
"service": "lab-portal",
"action": "export_requested",
"actor": "lab-reader",
"record_count": 3,
"result": "authorized"
}
}
Visibility limits: Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.
File Access · source-mapped
DC0055 collection page — Enable Audit File System plus a narrow SACL on a lab directory; on Linux select path/syscall rules and join associated Audit records.
Providers and collection configuration
- Use a lab-only GPO under Computer Configuration → Windows Settings → Security Settings → Advanced Audit Policy Configuration. Enable the specific subcategory named below.
- For object-level auditing, configure a narrow system access control list (SACL) on the test object in addition to policy. Do not audit an entire production directory by default.
- Forward Security events from the responsible host or controller; retain subject and target identities, object identifiers, result and original XML. Confirm effective policy with auditpol /get /category:*.
Required normalized fields: path, access, actor, result.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0055",
"collector": "illustrative-lab-collector",
"observation": {
"path": "C:\\Lab\\demo.txt",
"access": "read",
"actor": "LAB\\analyst",
"result": "success"
}
}
Visibility limits: A policy checkbox alone does not guarantee an event. Host role, SACL, success/failure selection and audit policy precedence matter. Directory changes may arrive as multiple records.
Network Connection Creation · source-mapped
DC0082 collection page — Enable scoped Sysmon NetworkConnect (3), disabled by default, or a platform-equivalent process-aware network sensor.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_guid, destination_ip, destination_port, protocol, initiated.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0082",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"destination_ip": "198.51.100.20",
"destination_port": 443,
"protocol": "tcp",
"initiated": true
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Process Creation · source-mapped
DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_guid, image, parent_image, command_line, user.
<EventFiltering>
<ProcessCreate onmatch="include">
<Image condition="is">C:\Windows\System32\whoami.exe</Image>
</ProcessCreate>
</EventFiltering>
This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0032",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"image": "C:\\Windows\\System32\\whoami.exe",
"parent_image": "C:\\Windows\\System32\\cmd.exe",
"command_line": "whoami",
"user": "LAB\\analyst"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Script Execution · source-mapped
DC0029 collection page — Collect PowerShell 4104 with script-block ID and fragment sequence; instrument other engines separately rather than assigning them the same event ID.
Providers and collection configuration
- Enable Script Block Logging through the policy/configuration for the installed edition. Forward Microsoft-Windows-PowerShell/Operational for Windows PowerShell, or PowerShellCore/Operational for PowerShell 7.
- Retain script-block ID and fragment ordering alongside process creation. Protect access to collected script text; secrets may be included.
- On Linux, use narrowly scoped Audit execution rules for the lab account and supported architectures, and retain joined SYSCALL/EXECVE/PATH records.
Required normalized fields: engine, script_block_id, fragment, fragments_total, script_text.
Get-WinEvent -FilterHashtable @{
LogName = 'Microsoft-Windows-PowerShell/Operational'
Id = 4104
} -MaxEvents 5
Read-only check after Script Block Logging is configured. For PowerShell 7 use its registered PowerShellCore/Operational channel. Missing events are not proof of no execution; check policy, channel and permissions.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0029",
"collector": "illustrative-lab-collector",
"observation": {
"engine": "PowerShell",
"script_block_id": "lab-script-1",
"fragment": 1,
"fragments_total": 1,
"script_text": "Write-Output \"LAB_TELEMETRY_CHECK\""
}
}
Visibility limits: Script content and process command lines are different signals. Logging may be partial, fragmented, filtered or disabled; never assume a command line reveals everything executed.