T0802 Automated Collection — Detection Rules
Detection workspace for T0802 Automated Collection: 0 Sigma sources, 0 Atlas concepts and 0 anomaly models. No live detection validation.
Source-backed rule directory
No reviewed association in this snapshot.
Atlas deterministic concepts
No exact concept selected.
Anomaly models
No exact Atlas model in this snapshot.
ATT&CK analytic guidance
DET0734 Detection of Automated Collection
AN1867 Analytic 1867
Real-time network monitoring identifies a source issuing systematic, sequential Industrial Control System (ICS) protocol reads sweeping the full register/address range across multiple field devices within a short time window, from a source not in the approved control server list. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
AN2128 Analytic 2128
Real-time monitoring identifies a scripting interpreter process iterating through Industrial Control System (ICS) data sources and writing output to a local file or piping to a network socket, by a User Identifier (UID) not associated with documented automation scripts. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
AN2270 Analytic 2270
Real-time monitoring identifies a host process making sequential Industrial Control System (ICS) protocol reads with output piped to a local staging file, from a process not associated with a recognized Human-Machine Interface (HMI) or historian tool. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
Connected ecosystem references
Linked tags
Simulation, tools and telemetry
- Command Execution · DC0064
- File Creation · DC0039
- Network Traffic Content · DC0085
- Script Execution · DC0029
No reviewed association in this snapshot.
Existing anomaly research
Complete technique engineering workbook
Collection configuration and event examples · Anomaly models and design worksheet · Tools and documented software · Simulation procedures · Offline synthetic collection check
Exact source tags are not semantic relevance verdicts. Review actual rule conditions and observation points; imported rules are not backend-compiled or live-validated.