1200KM / telemetry
Asset Inventory — Detection Telemetry
Inventory of operational assets, identities, roles and network relationships.
Collection and providers
Prefer approved inventory exports and passive discovery; retain model, firmware, owner and observation source. Do not scan a production control network as a default collection step.
- OPC UA audit-capable servers: Auditable actions where supported and enabled; inspect server conformance and vendor documentation.
- Controller, HMI and historian exports: Vendor-specific process values, quality flags, alarms and operational context.
- Independent lab sensors / safety records: Physical-effect corroboration, not a universal cybersecurity log format.
Configuration
- Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.
- Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.
- Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs.
Synthetic event example
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0110",
"collector": "illustrative-lab-collector",
"observation": {
"asset_id": "lab-controller-1",
"role": "PLC_fixture",
"firmware": "lab-1.0",
"source": "approved_inventory"
}
}Visibility and validation
There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.
- Record the lab scope, collector version, effective configuration and expected source fields before testing.
- Use an approved benign action or read-only snapshot appropriate to this type. For destructive, privileged or physical effects, use a reviewed fixture or existing authorized evidence instead of causing the effect.
- Verify the native source record locally and at the collector; compare timestamps, identity, object, action/result and the type-specific fields listed below. Save a redacted real capture separately from the synthetic example.
- Check a normal baseline and collector-loss case. Fixture parsing proves parser behavior only; it does not prove sensor coverage or malicious-behavior detection.
Primary sources
Connected ecosystem references
Linked tags
Related simulations and detection workspaces
Each workspace retains its own logsource and platform requirements. A technique-level association is not a per-rule sensor mapping.
- T0836 · Modify Parameter · Detection rules & anomalies
- T0838 · Modify Alarm Settings · Detection rules & anomalies
- T0843 · Program Download · Detection rules & anomalies
- T0843.001 · Download All · Detection rules & anomalies
- T0843.002 · Online Edit · Detection rules & anomalies
- T0843.003 · Program Append · Detection rules & anomalies
- T0848 · Rogue Master · Detection rules & anomalies
Attack tools through shared TTPs
These are two-hop navigation links through explicitly associated techniques, not independent tool-to-sensor assertions.
No reviewed association in this snapshot.
Connected anomaly research
Curated research views reached through an exact source technique, a catalog model, or a reviewed collection reference. These are navigation associations, not claims of detector effectiveness or sensor equivalence.
Telemetry contracts · Maintained query examples · Validation and blind spots
Pinned research references. No browser attack runner, live simulation result or validated detector is asserted. Source mappings and validation limits are preserved. ATT&CK / Atomic provenance · Detection provenance.