Adversaries may seek to capture process values related to the inputs and outputs of a PLC. During the scan cycle, a PLC reads the status of all inputs and stores them in an image table. The image table is the PLCs internal storage location where values of inputs/outputs for one scan are stored while it executes the user program. After the PLC has solved the entire logic program, it updates the output image table. The contents of this output…
Complete technique description
Adversaries may seek to capture process values related to the inputs and outputs of a PLC. During the scan cycle, a PLC reads the status of all inputs and stores them in an image table. [Nanjundaiah, Vaidyanath] The image table is the PLCs internal storage location where values of inputs/outputs for one scan are stored while it executes the user program. After the PLC has solved the entire logic program, it updates the output image table. The contents of this output image table are written to the corresponding output points in I/O Modules.
The Input and Output Image tables described above make up the I/O Image on a PLC. This image is used by the user program instead of directly interacting with physical I/O. [Spenneberg, Ralf 2016]
Adversaries may collect the I/O Image state of a PLC by utilizing a devices Native API to access the memory regions directly. The collection of the PLCs I/O state could be used to replace values or inform future stages of an attack.
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
Network Traffic Content · source-mapped
DC0085 collection page — Scope approved packet capture/protocol content collection to the lab flow; retain capture provenance and truncation indicators.
Providers and collection configuration
Zeek: Connection and protocol metadata from traffic visible to the sensor.
Suricata EVE: Configured flow, alert, DNS, HTTP, TLS and protocol records.
Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.
Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.
Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection.
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
Visibility limits: Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.
Real-time monitoring identifies a single Industrial Control System (ICS) protocol session reading the complete Input/Output (I/O) image from a field device, rather than the sparse, fixed tag subset that legitimate Supervisory Control and Data Acquisition (SCADA) polling queries, from a source not in the approved control server list. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
Platforms: Embedded.
Network Traffic Content — NSM:Content; channel single session reads address range covering above full image coverage threshold percent of device total Input/Output (I/O) space, from source not in approved Supervisory Control and Data Acquisition (SCADA) servers.
Source rule directory and observation requirements
No exact-tagged Sigma source rule was imported. This does not establish that the technique is undetectable; the MITRE guidance and collection requirements remain relevant.
Before treating a rule as coverage
Read the actual condition and logsource; identify attacker-side, victim-side or third-party visibility.
Map native sensor fields, parse times and identities, then compile for the selected backend.
Replay a behavior-positive case, a normal control, an authorized look-alike and a missing-telemetry case.
Record matches and misses with rule version and source events. No match is inconclusive when required telemetry is absent.
Anomaly-based detection
No exact technique-specific Atlas model is present for T0877 in the selected source snapshot. The following is a design worksheet, not a newly validated model.
Anomaly engineering worksheet
Start from the exact analytic above. The collection-specific lenses below are analyst recommendations; they do not assert that an arbitrary statistical deviation detects this technique.
Network and protocol telemetry: Per source and observation point: connection rate, destination-host/port fan-out, response/failure ratio and previously unseen destinations. Compare equivalent time windows; separate authorized scanners, NAT and sampling effects.
Define an entity/peer group and feature; exclude the evaluation period from baseline training.
Use representative normal and maintenance activity. Do not invent a production threshold from a synthetic example.
Evaluate held-out behavior-positive and benign cases; measure false positives, misses and telemetry loss separately.
Keep abnormality separate from maliciousness. Correlate with the behavior-specific source evidence.
No reviewed lab-tool association is selected for this exact technique. This is a curation gap, not a statement that no tool can implement the behavior.
Software observed in source procedures
These are exact ATT&CK software-use relationships, including malware. They provide behavior context, not recommendations to download or execute malware. No safety or detector claim is inherited.
Stuxnet copies the input area of an I/O image into data blocks with a one second interval between copies, forming a 21 second recording of the input area. The input area contains information being passed to the PLC from a peripheral. For example, the current state of a valve or the temperature of a device. [Nicolas Falliere, Liam O Murchu, Eric Chien February 2011]
Atomic evidence: no compatible candidate in this snapshot. Live lab status: not run for these imported procedures.
Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.
No compatible Atomic procedure is present in this pinned evidence set. Technical feasibility has not been ruled out. A custom procedure must define the behavior, target, collection point, success observable and rollback before execution.
Technique-specific experiment contract
Choose one procedure implementing T0877 I/O Image; identify the observable behavior in the source definition, not just its tactic.
Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
Enable the collection sources above and verify a benign baseline reaches the detector.
Run only the approved isolated scenario; capture native events and an independent behavior observable.
Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.
This fixture exercises the listed collection fields. It does not reproduce I/O Image, label its example events as malicious, or measure detection effectiveness. Use the exact analytic and selected procedure to build an independently labelled behavior-positive dataset.
Not run in this browser. No network scan or attack command is executed by this control.
Validation status and remaining work
Source identity
Joined by exact technique/object IDs against hash-pinned sources.
Collection fixture
Available for offline schema exercises; not attack emulation.
Native telemetry / backend / real attack
Not validated for these imported procedures. Source fidelity and page tests cannot establish sensor or detector effectiveness.
Pinned MITRE STIX source · SHA-256 c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183. Definition and procedure context are reproduced from this snapshot, not independently re-investigated incidents.
Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.