1200kmSECURITY RESEARCH
Loading interactive filters…

1200KM / simulation

T1137.002 Office Test — Attack Simulation

Adversaries may abuse the Microsoft Office "Office Test" Registry key to obtain persistence on a compromised system. An Office Test Registry location exists that allows a user to specify an arbitrary DLL that will be executed every time an Office application is started. This Registry key is thought to be used by Microsoft to load DLLs for testing and debugging purposes while developing Office applications. This Registry key is not created by…

Complete technique description

Adversaries may abuse the Microsoft Office "Office Test" Registry key to obtain persistence on a compromised system. An Office Test Registry location exists that allows a user to specify an arbitrary DLL that will be executed every time an Office application is started. This Registry key is thought to be used by Microsoft to load DLLs for testing and debugging purposes while developing Office applications. This Registry key is not created by default during an Office installation.[Hexacorn Office Test][Palo Alto Office Test Sofacy]

There exist user and global Registry keys for the Office Test feature, such as:

* <code>HKEY_CURRENT_USER\Software\Microsoft\Office test\Special\Perf</code>
* <code>HKEY_LOCAL_MACHINE\Software\Microsoft\Office test\Special\Perf</code>

Adversaries may add this Registry key and specify a malicious DLL that will be executed whenever an Office application, such as Word or Excel, is started.

Official technique definition · Open in the interactive matrix

Parent and sub-techniques

Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.

Detection telemetry and configuration

These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.

Command Execution · source-mapped

DC0064 collection page — Collect process command lines and relevant shell/interpreter audit; shell history alone is neither complete nor tamper-resistant.

Providers and collection configuration

  • Enable Script Block Logging through the policy/configuration for the installed edition. Forward Microsoft-Windows-PowerShell/Operational for Windows PowerShell, or PowerShellCore/Operational for PowerShell 7.
  • Retain script-block ID and fragment ordering alongside process creation. Protect access to collected script text; secrets may be included.
  • On Linux, use narrowly scoped Audit execution rules for the lab account and supported architectures, and retain joined SYSCALL/EXECVE/PATH records.

Required normalized fields: interpreter, command_line, actor_uid, session_id.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0064",
  "collector": "illustrative-lab-collector",
  "observation": {
    "interpreter": "/bin/sh",
    "command_line": "printf LAB_TELEMETRY_CHECK",
    "actor_uid": 1000,
    "session_id": "lab-session-1"
  }
}

Visibility limits: Script content and process command lines are different signals. Logging may be partial, fragmented, filtered or disabled; never assume a command line reveals everything executed.

File Creation · source-mapped

DC0039 collection page — Scope Sysmon FileCreate (11) to the lab directory; retain the process and file path. Differentiate creation/overwrite if the sensor can.

Providers and collection configuration

  • Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
  • Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
  • Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
  • On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
  • Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
  • For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.

Required normalized fields: process_id, path, action, size_bytes.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0039",
  "collector": "illustrative-lab-collector",
  "observation": {
    "process_id": 4200,
    "path": "C:\\Lab\\demo.txt",
    "action": "create",
    "size_bytes": 64
  }
}

Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.

Module Load · source-mapped

DC0016 collection page — Scope Sysmon ImageLoad (7) to lab processes/paths; retain module hash, signer and destination process. Inventory alone does not prove a module loaded.

Providers and collection configuration

  • Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
  • Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
  • Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
  • On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
  • Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
  • For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.

Required normalized fields: process_id, image_loaded, signed, action.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0016",
  "collector": "illustrative-lab-collector",
  "observation": {
    "process_id": 4200,
    "image_loaded": "C:\\Lab\\demo.dll",
    "signed": false,
    "action": "load"
  }
}

Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.

Process Creation · source-mapped

DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.

Providers and collection configuration

  • Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
  • Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
  • Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
  • On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
  • Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
  • For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.

Required normalized fields: process_guid, image, parent_image, command_line, user.

<EventFiltering>
  <ProcessCreate onmatch="include">
    <Image condition="is">C:\Windows\System32\whoami.exe</Image>
  </ProcessCreate>
</EventFiltering>

This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0032",
  "collector": "illustrative-lab-collector",
  "observation": {
    "process_guid": "lab-process-001",
    "image": "C:\\Windows\\System32\\whoami.exe",
    "parent_image": "C:\\Windows\\System32\\cmd.exe",
    "command_line": "whoami",
    "user": "LAB\\analyst"
  }
}

Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.

Windows Registry Key Modification · source-mapped

DC0063 collection page — Use RegistryEvent 13 for value-set and 14 for rename; compare against intended policy and keep original type/value where available.

Providers and collection configuration

  • Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
  • On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
  • Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
  • Keep this Windows-specific source separate from other operating systems; there is no direct cross-platform event-ID equivalence.

Required normalized fields: registry_path, event_type, value_type, value.

Illustrative collection event

Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.

{
  "schema": "1200km.telemetry.example.v1",
  "synthetic": true,
  "timestamp": "2026-09-27T12:00:00Z",
  "telemetry_id": "DC0063",
  "collector": "illustrative-lab-collector",
  "observation": {
    "registry_path": "HKCU\\Software\\Lab\\Mode",
    "event_type": "SetValue",
    "value_type": "DWORD",
    "value": 1
  }
}

Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.

Detection rules and analytic guidance

Open the dedicated detection workspace · Existing query engineering

DET0315 Detect Persistence via Office Test Registry DLL Injection

MITRE detection strategy

AN0880 Analytic 0880

Adversaries create the 'Office Test\Special\Perf' registry key and specify a malicious DLL path that is auto-loaded when an Office application starts. This DLL is injected into the Office process memory space and can provide persistent execution without requiring macro enablement.

Platforms: Windows.

AN0881 Analytic 0881

Office application auto-loads a non-standard DLL during startup triggered via Office Test Registry key, often without macro warning banners. DLL persistence mechanism circumvents traditional macro defenses.

Platforms: Office Suite.

  • Module Load — m365:unified; channel Non-standard Office startup component detected (e.g., unexpected DLL path).
  • Command Execution — m365:office; channel Startup execution includes non-default component.
Source rule directory and observation requirements

2 exact-tagged source rules. A source tag is a discovery aid, not a relevance verdict. Check the observation point and actual condition of each rule.

Before treating a rule as coverage

  1. Read the actual condition and logsource; identify attacker-side, victim-side or third-party visibility.
  2. Map native sensor fields, parse times and identities, then compile for the selected backend.
  3. Replay a behavior-positive case, a normal control, an authorized look-alike and a missing-telemetry case.
  4. Record matches and misses with rule version and source events. No match is inconclusive when required telemetry is absent.

Anomaly-based detection

No exact technique-specific Atlas model is present for T1137.002 in the selected source snapshot. The following is a design worksheet, not a newly validated model.

Anomaly engineering worksheet

Start from the exact analytic above. The collection-specific lenses below are analyst recommendations; they do not assert that an arbitrary statistical deviation detects this technique.

  • Script and command execution: Per host role and principal: rare interpreters, command argument patterns and parent-child sequences. Normalize scripts carefully; obfuscation, administrative automation and missing command lines change visibility.
  • Endpoint activity: Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity.
  1. Define an entity/peer group and feature; exclude the evaluation period from baseline training.
  2. Use representative normal and maintenance activity. Do not invent a production threshold from a synthetic example.
  3. Evaluate held-out behavior-positive and benign cases; measure false positives, misses and telemetry loss separately.
  4. Keep abnormality separate from maliciousness. Correlate with the behavior-specific source evidence.

Anomaly Detection Atlas · Baseline, validation and blind spots

Attack tools and documented software

No reviewed lab-tool association is selected for this exact technique. This is a curation gap, not a statement that no tool can implement the behavior.

Simulation design and documented procedures

Atomic evidence: 1 compatible documented candidates. Live lab status: not run for these imported procedures.

Use disposable lab hosts and test accounts, explicit target allowlists, a clean snapshot, bounded egress and a restore plan. Review every candidate and dependency before any execution.

Office Application Startup Test Persistence (HKCU)

Office Test Registry location exists that allows a user to specify an arbitrary DLL that will be executed every time an Office
application is started. Key is used for debugging purposes. Not created by default & exist in HKCU & HKLM hives.

Pinned Atomic procedure · c3e35b58-fe1c-480b-b540-7600fb612563 · windows · powershell.

Elevation: not declared required. Cleanup: defined upstream; review required. This is source documentation, not an execution approval.

No input arguments declared.

Review the upstream command, dependencies and cleanup at the source link. Source defaults may refer to real infrastructure or destructive actions; they are not authorized targets. No automatic install, prerequisite download or command execution is provided.

2 prerequisite definitions:

  • Microsoft Word must be installed
  • DLL files must exist on disk at specified location

Technique-specific experiment contract

  1. Choose one procedure implementing T1137.002 Office Test; identify the observable behavior in the source definition, not just its tactic.
  2. Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
  3. Enable the collection sources above and verify a benign baseline reaches the detector.
  4. Run only the approved isolated scenario; capture native events and an independent behavior observable.
  5. Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.

Synthetic logs and offline contract check

Download synthetic collection fixture (JSON) · Download the complete engineering workbook

This fixture exercises the listed collection fields. It does not reproduce Office Test, label its example events as malicious, or measure detection effectiveness. Use the exact analytic and selected procedure to build an independently labelled behavior-positive dataset.

Not run in this browser. No network scan or attack command is executed by this control.

Validation status and remaining work

Source identity
Joined by exact technique/object IDs against hash-pinned sources.
Collection fixture
Available for offline schema exercises; not attack emulation.
Native telemetry / backend / real attack
Not validated for these imported procedures. Source fidelity and page tests cannot establish sensor or detector effectiveness.

All-page audit and evidence inventory · This page’s machine-readable workbook

Sources and evidence boundaries

Pinned MITRE STIX source · SHA-256 81113ba98afa2928f3dcff62022539f7ce30c315c32e14422f11ff95ce534352. Definition and procedure context are reproduced from this snapshot, not independently re-investigated incidents.

Source-linked mitigations

Connected ecosystem references

Linked tags

Source procedure platform / method / executor tags:

Detection and collection

T1137.002 detection workspace

No reviewed association in this snapshot.

Threat actor context

These are explicit actor-to-technique associations in the existing Threat Matrix snapshot, not attribution of an event or proof that a detector identifies the actor. No tool-to-actor relationship is inferred.

Existing research

Threat Matrix: knowledge routes, evidence and actor context

Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.