1200KM / detection
T0893 Data from Local System — Detection Rules
Detection workspace for T0893 Data from Local System: 0 Sigma sources, 0 Atlas concepts and 0 anomaly models. No live detection validation.
Source-backed rule directory
No reviewed association in this snapshot.
Atlas deterministic concepts
No exact concept selected.
Anomaly models
No exact Atlas model in this snapshot.
ATT&CK analytic guidance
DET0749 Detection of Data from Local System
AN1881 Analytic 1881
Monitor Windows Security Event ID 4663 on explicitly audited ICS data paths and correlate repeated ReadData/ListDirectory access across multiple sensitive files or directories by an account/process outside the approved engineering, backup, or application baseline. This requires Object Access auditing and SACLs on the monitored paths; Sysmon does not provide generic file-read telemetry. Alert when the bulk-read pattern occurs outside an approved backup/export window or is followed by staging, compression, or network transfer.
AN2137 Analytic 2137
Real-time monitoring identifies a Linux process performing sequential reads across multiple ICS configuration or data paths by a UID outside approved backup, engineering, or vendor-application accounts. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
AN2174 Analytic 2174
Real-time monitoring identifies large outbound data transfers from Industrial Control System (ICS) server Internet Protocol (IP) addresses to destinations outside the approved ICS zone, following a pattern of bulk reads from engineering document stores or historian databases. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
AN2244 Analytic 2244
Real-time monitoring identifies Industrial Control System (ICS) protocol sessions that bulk-read configuration data, program blocks, or data record objects from field devices -- function code sequences retrieving entire data dictionaries rather than operational process values -- from a source with no prior history of configuration-read sessions. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
Connected ecosystem references
Linked tags
Simulation, tools and telemetry
- Command Execution · DC0064
- File Access · DC0055
- Network Traffic Content · DC0085
- Network Traffic Flow · DC0078
- Process Creation · DC0032
No reviewed association in this snapshot.
Existing anomaly research
Complete technique engineering workbook
Collection configuration and event examples · Anomaly models and design worksheet · Tools and documented software · Simulation procedures · Offline synthetic collection check
Exact source tags are not semantic relevance verdicts. Review actual rule conditions and observation points; imported rules are not backend-compiled or live-validated.
Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.