Complete technique description
Adversaries may abuse the <code>KernelCallbackTable</code> of a process to hijack its execution flow in order to run their own payloads.[Lazarus APT January 2022][FinFisher exposed ] The <code>KernelCallbackTable</code> can be found in the Process Environment Block (PEB) and is initialized to an array of graphic functions available to a GUI process once <code>user32.dll</code> is loaded.[Windows Process Injection KernelCallbackTable]
An adversary may hijack the execution flow of a process using the <code>KernelCallbackTable</code> by replacing an original callback function with a malicious payload. Modifying callback functions can be achieved in various ways involving related behaviors such as Reflective Code Loading or Process Injection into another process.
A pointer to the memory address of the <code>KernelCallbackTable</code> can be obtained by locating the PEB (ex: via a call to the <code>NtQueryInformationProcess()</code> Native API function).[NtQueryInformationProcess] Once the pointer is located, the <code>KernelCallbackTable</code> can be duplicated, and a function in the table (e.g., <code>fnCOPYDATA</code>) set to the address of a malicious payload (ex: via <code>WriteProcessMemory()</code>). The PEB is then updated with the new address of the table. Once the tampered function is invoked, the malicious payload will be triggered.[Lazarus APT January 2022]
The tampered function is typically invoked using a Windows message. After the process is hijacked and malicious code is executed, the <code>KernelCallbackTable</code> may also be restored to its original state by the rest of the malicious payload.[Lazarus APT January 2022] Use of the <code>KernelCallbackTable</code> to hijack execution flow may evade detection from security products since the execution can be masked under a legitimate process.
Official technique definition · Open in the interactive matrix
Parent and sub-techniques
Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.
Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
OS API Execution · source-mapped
DC0021 collection page — Use an approved EDR trace or instrument the owned lab process at selected APIs. Define API name, caller, sanitized arguments and return status.
Providers and collection configuration
- Enable the application audit category or instrument the owned lab application at the authorization/action boundary.
- Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.
- Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart.
Required normalized fields: process_id, api, path, result.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0021",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"api": "CreateFileW",
"path": "C:\\Lab\\demo.txt",
"result": "success"
}
}
Visibility limits: Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.
Process Access · source-mapped
DC0035 collection page — Scope Sysmon ProcessAccess (10) to the selected source/target processes and access rights; retain call-trace fields where emitted.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: source_process_id, target_process_id, granted_access, action.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0035",
"collector": "illustrative-lab-collector",
"observation": {
"source_process_id": 4200,
"target_process_id": 4300,
"granted_access": "0x1000",
"action": "open_process"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Process Creation · source-mapped
DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_guid, image, parent_image, command_line, user.
<EventFiltering>
<ProcessCreate onmatch="include">
<Image condition="is">C:\Windows\System32\whoami.exe</Image>
</ProcessCreate>
</EventFiltering>
This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0032",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"image": "C:\\Windows\\System32\\whoami.exe",
"parent_image": "C:\\Windows\\System32\\cmd.exe",
"command_line": "whoami",
"user": "LAB\\analyst"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Simulation design and documented procedures
Atomic evidence: no compatible candidate in this snapshot. Live lab status: not run for these imported procedures.
Use disposable lab hosts and test accounts, explicit target allowlists, a clean snapshot, bounded egress and a restore plan. Review every candidate and dependency before any execution.
No compatible Atomic procedure is present in this pinned evidence set. Technical feasibility has not been ruled out. A custom procedure must define the behavior, target, collection point, success observable and rollback before execution.
Technique-specific experiment contract
- Choose one procedure implementing T1574.013 KernelCallbackTable; identify the observable behavior in the source definition, not just its tactic.
- Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
- Enable the collection sources above and verify a benign baseline reaches the detector.
- Run only the approved isolated scenario; capture native events and an independent behavior observable.
- Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.