Complete technique description
Adversaries may modify systems in order to manipulate the data as it is accessed and displayed to an end user, thus threatening the integrity of the data.[FireEye APT38 Oct 2018][DOJ Lazarus Sony 2018] By manipulating runtime data, adversaries may attempt to affect a business process, organizational understanding, and decision making.
Adversaries may alter application binaries used to display data in order to cause runtime manipulations. Adversaries may also conduct Change Default File Association and Masquerading to cause a similar effect. The type of modification and the impact it will have depends on the target application and process as well as the goals and objectives of the adversary. For complex systems, an adversary would likely need special expertise and possibly access to specialized software related to the system that would typically be gained through a prolonged information gathering campaign in order to have the desired impact.
Official technique definition · Open in the interactive matrix
Parent and sub-techniques
Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.
Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
File Creation · source-mapped
DC0039 collection page — Scope Sysmon FileCreate (11) to the lab directory; retain the process and file path. Differentiate creation/overwrite if the sensor can.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, path, action, size_bytes.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0039",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"path": "C:\\Lab\\demo.txt",
"action": "create",
"size_bytes": 64
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
File Metadata · source-mapped
DC0059 collection page — Collect scoped file inventory/FIM metadata with hash algorithm and observation time; preserve original timestamps separately from collector time.
Providers and collection configuration
- osquery: Scheduled host-state queries; supported tables and privileges vary by OS. Select a table that actually exposes the required object.
- Linux Audit plus inventory snapshots: Events explain changes; snapshots describe state at collection time.
- Define the inventory query, allowed host set, interval and least-privileged reader. Store a stable asset ID, observation time and collector version.
- Keep successive snapshots and calculate additions, removals and changed attributes. Pair state changes with audit events when available.
- Export collector health and missed-poll counts so a missing snapshot is not misclassified as a missing asset.
Required normalized fields: path, size_bytes, sha256, owner_uid.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0059",
"collector": "illustrative-lab-collector",
"observation": {
"path": "/opt/lab/demo.txt",
"size_bytes": 64,
"sha256": "aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa",
"owner_uid": 1000
}
}
Visibility limits: Snapshots miss short-lived objects and do not identify who caused a change. A generic inventory agent is not guaranteed to expose firmware or kernel-level details.
File Modification · source-mapped
DC0061 collection page — Use file-integrity monitoring or scoped OS file-write auditing for general changes. Sysmon 2 records creation-time changes; it is not a general file-write event.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: path, attribute, before, after.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0061",
"collector": "illustrative-lab-collector",
"observation": {
"path": "C:\\Lab\\demo.txt",
"attribute": "content_hash",
"before": "aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa",
"after": "bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
OS API Execution · source-mapped
DC0021 collection page — Use an approved EDR trace or instrument the owned lab process at selected APIs. Define API name, caller, sanitized arguments and return status.
Providers and collection configuration
- Enable the application audit category or instrument the owned lab application at the authorization/action boundary.
- Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.
- Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart.
Required normalized fields: process_id, api, path, result.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0021",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"api": "CreateFileW",
"path": "C:\\Lab\\demo.txt",
"result": "success"
}
}
Visibility limits: Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.
Windows Registry Key Modification · source-mapped
DC0063 collection page — Use RegistryEvent 13 for value-set and 14 for rename; compare against intended policy and keep original type/value where available.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- Keep this Windows-specific source separate from other operating systems; there is no direct cross-platform event-ID equivalence.
Required normalized fields: registry_path, event_type, value_type, value.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0063",
"collector": "illustrative-lab-collector",
"observation": {
"registry_path": "HKCU\\Software\\Lab\\Mode",
"event_type": "SetValue",
"value_type": "DWORD",
"value": 1
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.