Complete technique description
Adversaries may use port monitors to run an adversary supplied DLL during system boot for persistence or privilege escalation. A port monitor can be set through the <code>AddMonitor</code> API call to set a DLL to be loaded at startup.[AddMonitor] This DLL can be located in <code>C:\Windows\System32</code> and will be loaded and run by the print spooler service, `spoolsv.exe`, under SYSTEM level permissions on boot.[Bloxham]
Alternatively, an arbitrary DLL can be loaded if permissions allow writing a fully-qualified pathname for that DLL to the `Driver` value of an existing or new arbitrarily named subkey of <code>HKLM\SYSTEM\CurrentControlSet\Control\Print\Monitors</code>. The Registry key contains entries for the following:
* Local Port
* Standard TCP/IP Port
* USB Monitor
* WSD Port
Official technique definition · Open in the interactive matrix
Parent and sub-techniques
Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.
Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
File Creation · source-mapped
DC0039 collection page — Scope Sysmon FileCreate (11) to the lab directory; retain the process and file path. Differentiate creation/overwrite if the sensor can.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, path, action, size_bytes.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0039",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"path": "C:\\Lab\\demo.txt",
"action": "create",
"size_bytes": 64
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Module Load · source-mapped
DC0016 collection page — Scope Sysmon ImageLoad (7) to lab processes/paths; retain module hash, signer and destination process. Inventory alone does not prove a module loaded.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, image_loaded, signed, action.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0016",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"image_loaded": "C:\\Lab\\demo.dll",
"signed": false,
"action": "load"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
OS API Execution · source-mapped
DC0021 collection page — Use an approved EDR trace or instrument the owned lab process at selected APIs. Define API name, caller, sanitized arguments and return status.
Providers and collection configuration
- Enable the application audit category or instrument the owned lab application at the authorization/action boundary.
- Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.
- Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart.
Required normalized fields: process_id, api, path, result.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0021",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"api": "CreateFileW",
"path": "C:\\Lab\\demo.txt",
"result": "success"
}
}
Visibility limits: Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.
Process Creation · source-mapped
DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_guid, image, parent_image, command_line, user.
<EventFiltering>
<ProcessCreate onmatch="include">
<Image condition="is">C:\Windows\System32\whoami.exe</Image>
</ProcessCreate>
</EventFiltering>
This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0032",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"image": "C:\\Windows\\System32\\whoami.exe",
"parent_image": "C:\\Windows\\System32\\cmd.exe",
"command_line": "whoami",
"user": "LAB\\analyst"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Windows Registry Key Modification · source-mapped
DC0063 collection page — Use RegistryEvent 13 for value-set and 14 for rename; compare against intended policy and keep original type/value where available.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- Keep this Windows-specific source separate from other operating systems; there is no direct cross-platform event-ID equivalence.
Required normalized fields: registry_path, event_type, value_type, value.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0063",
"collector": "illustrative-lab-collector",
"observation": {
"registry_path": "HKCU\\Software\\Lab\\Mode",
"event_type": "SetValue",
"value_type": "DWORD",
"value": 1
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.