Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
Command Execution · source-mapped
DC0064 collection page — Collect process command lines and relevant shell/interpreter audit; shell history alone is neither complete nor tamper-resistant.
Providers and collection configuration
- Enable Script Block Logging through the policy/configuration for the installed edition. Forward Microsoft-Windows-PowerShell/Operational for Windows PowerShell, or PowerShellCore/Operational for PowerShell 7.
- Retain script-block ID and fragment ordering alongside process creation. Protect access to collected script text; secrets may be included.
- On Linux, use narrowly scoped Audit execution rules for the lab account and supported architectures, and retain joined SYSCALL/EXECVE/PATH records.
Required normalized fields: interpreter, command_line, actor_uid, session_id.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0064",
"collector": "illustrative-lab-collector",
"observation": {
"interpreter": "/bin/sh",
"command_line": "printf LAB_TELEMETRY_CHECK",
"actor_uid": 1000,
"session_id": "lab-session-1"
}
}
Visibility limits: Script content and process command lines are different signals. Logging may be partial, fragmented, filtered or disabled; never assume a command line reveals everything executed.
File Creation · source-mapped
DC0039 collection page — Scope Sysmon FileCreate (11) to the lab directory; retain the process and file path. Differentiate creation/overwrite if the sensor can.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, path, action, size_bytes.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0039",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"path": "C:\\Lab\\demo.txt",
"action": "create",
"size_bytes": 64
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Module Load · source-mapped
DC0016 collection page — Scope Sysmon ImageLoad (7) to lab processes/paths; retain module hash, signer and destination process. Inventory alone does not prove a module loaded.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, image_loaded, signed, action.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0016",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"image_loaded": "C:\\Lab\\demo.dll",
"signed": false,
"action": "load"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Network Connection Creation · source-mapped
DC0082 collection page — Enable scoped Sysmon NetworkConnect (3), disabled by default, or a platform-equivalent process-aware network sensor.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_guid, destination_ip, destination_port, protocol, initiated.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0082",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"destination_ip": "198.51.100.20",
"destination_port": 443,
"protocol": "tcp",
"initiated": true
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Process Creation · source-mapped
DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_guid, image, parent_image, command_line, user.
<EventFiltering>
<ProcessCreate onmatch="include">
<Image condition="is">C:\Windows\System32\whoami.exe</Image>
</ProcessCreate>
</EventFiltering>
This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0032",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"image": "C:\\Windows\\System32\\whoami.exe",
"parent_image": "C:\\Windows\\System32\\cmd.exe",
"command_line": "whoami",
"user": "LAB\\analyst"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Windows Registry Key Creation · source-mapped
DC0056 collection page — Use RegistryEvent (12) and filter CreateKey/CreateValue as available; retain target object and process identity.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- Keep this Windows-specific source separate from other operating systems; there is no direct cross-platform event-ID equivalence.
Required normalized fields: registry_path, event_type, process_id.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0056",
"collector": "illustrative-lab-collector",
"observation": {
"registry_path": "HKCU\\Software\\Lab\\Demo",
"event_type": "CreateKey",
"process_id": 4200
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Windows Registry Key Modification · source-mapped
DC0063 collection page — Use RegistryEvent 13 for value-set and 14 for rename; compare against intended policy and keep original type/value where available.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- Keep this Windows-specific source separate from other operating systems; there is no direct cross-platform event-ID equivalence.
Required normalized fields: registry_path, event_type, value_type, value.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0063",
"collector": "illustrative-lab-collector",
"observation": {
"registry_path": "HKCU\\Software\\Lab\\Mode",
"event_type": "SetValue",
"value_type": "DWORD",
"value": 1
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Simulation design and documented procedures
Atomic evidence: 2 compatible documented candidates. Live lab status: not run for these imported procedures.
Use disposable lab hosts and test accounts, explicit target allowlists, a clean snapshot, bounded egress and a restore plan. Review every candidate and dependency before any execution.
Regasm Uninstall Method Call Test
Executes the Uninstall Method, No Admin Rights Required. Upon execution, "I shouldn't really execute either." will be displayed.
Pinned Atomic procedure · 71bfbfac-60b1-4fc0-ac8b-2cedbbdcb112 · windows · command_prompt.
Elevation: not declared required. Cleanup: defined upstream; review required. This is source documentation, not an execution approval.
output_file: Location of the payload (type path; source default %tmp%\T1218.009.dll)source_file: Location of the CSharp source_file (type path; source default PathToAtomicsFolder\T1218.009\src\T1218.009.cs)
Review the upstream command, dependencies and cleanup at the source link. Source defaults may refer to real infrastructure or destructive actions; they are not authorized targets. No automatic install, prerequisite download or command execution is provided.
1 prerequisite definitions:
- The CSharp source file must exist on disk at specified location (#{source_file})
Regsvcs Uninstall Method Call Test
Executes the Uninstall Method, No Admin Rights Required, Requires SNK. Upon execution, "I shouldn't really execute" will be displayed
along with other information about the assembly being installed.
Pinned Atomic procedure · fd3c1c6a-02d2-4b72-82d9-71c527abb126 · windows · powershell.
Elevation: required. Cleanup: defined upstream; review required. This is source documentation, not an execution approval.
output_file: Location of the payload (type path; source default $Env:TEMP\T1218.009.dll)source_file: Location of the CSharp source_file (type path; source default PathToAtomicsFolder\T1218.009\src\T1218.009.cs)
Review the upstream command, dependencies and cleanup at the source link. Source defaults may refer to real infrastructure or destructive actions; they are not authorized targets. No automatic install, prerequisite download or command execution is provided.
1 prerequisite definitions:
- The CSharp source file must exist on disk at specified location (#{source_file})
Technique-specific experiment contract
- Choose one procedure implementing T1218.009 Regsvcs/Regasm; identify the observable behavior in the source definition, not just its tactic.
- Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
- Enable the collection sources above and verify a benign baseline reaches the detector.
- Run only the approved isolated scenario; capture native events and an independent behavior observable.
- Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.