Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
Command Execution · source-mapped
DC0064 collection page — Collect process command lines and relevant shell/interpreter audit; shell history alone is neither complete nor tamper-resistant.
Providers and collection configuration
- Enable Script Block Logging through the policy/configuration for the installed edition. Forward Microsoft-Windows-PowerShell/Operational for Windows PowerShell, or PowerShellCore/Operational for PowerShell 7.
- Retain script-block ID and fragment ordering alongside process creation. Protect access to collected script text; secrets may be included.
- On Linux, use narrowly scoped Audit execution rules for the lab account and supported architectures, and retain joined SYSCALL/EXECVE/PATH records.
Required normalized fields: interpreter, command_line, actor_uid, session_id.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0064",
"collector": "illustrative-lab-collector",
"observation": {
"interpreter": "/bin/sh",
"command_line": "printf LAB_TELEMETRY_CHECK",
"actor_uid": 1000,
"session_id": "lab-session-1"
}
}
Visibility limits: Script content and process command lines are different signals. Logging may be partial, fragmented, filtered or disabled; never assume a command line reveals everything executed.
File Creation · source-mapped
DC0039 collection page — Scope Sysmon FileCreate (11) to the lab directory; retain the process and file path. Differentiate creation/overwrite if the sensor can.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, path, action, size_bytes.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0039",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"path": "C:\\Lab\\demo.txt",
"action": "create",
"size_bytes": 64
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Module Load · source-mapped
DC0016 collection page — Scope Sysmon ImageLoad (7) to lab processes/paths; retain module hash, signer and destination process. Inventory alone does not prove a module loaded.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, image_loaded, signed, action.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0016",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"image_loaded": "C:\\Lab\\demo.dll",
"signed": false,
"action": "load"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Process Access · source-mapped
DC0035 collection page — Scope Sysmon ProcessAccess (10) to the selected source/target processes and access rights; retain call-trace fields where emitted.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: source_process_id, target_process_id, granted_access, action.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0035",
"collector": "illustrative-lab-collector",
"observation": {
"source_process_id": 4200,
"target_process_id": 4300,
"granted_access": "0x1000",
"action": "open_process"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Process Creation · source-mapped
DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_guid, image, parent_image, command_line, user.
<EventFiltering>
<ProcessCreate onmatch="include">
<Image condition="is">C:\Windows\System32\whoami.exe</Image>
</ProcessCreate>
</EventFiltering>
This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0032",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"image": "C:\\Windows\\System32\\whoami.exe",
"parent_image": "C:\\Windows\\System32\\cmd.exe",
"command_line": "whoami",
"user": "LAB\\analyst"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.