Complete technique description
Adversaries may manipulate software dependencies and development tools prior to receipt by a final consumer for the purpose of data or system compromise. Applications often depend on external software to function properly. Popular open source projects that are used as dependencies in many applications, such as pip and NPM packages, may be targeted as a means to add malicious code to users of the dependency.[Trendmicro NPM Compromise][Bitdefender NPM Repositories Compromised 2021][MANDVI Malicious npm and PyPI Packages Disguised] This may also include abandoned packages, which in some cases could be re-registered by threat actors after being removed by adversaries.[The Hacker News PyPi Revival Hijack 2024] Adversaries may also employ "typosquatting" or name-confusion by choosing names similar to existing popular libraries or packages in order to deceive a user.[Ahmed Backdoors in Python and NPM Packages][Meyer PyPI Supply Chain Attack Uncovered][Checkmarx-oss-seo]
Additionally, CI/CD pipeline components, such as GitHub Actions, may be targeted in order to gain access to the building, testing, and deployment cycles of an application.[Unit 42 Palo Alto GitHub Actions Supply Chain Attack 2025] By adding malicious code into a GitHub action, a threat actor may be able to collect runtime credentials (e.g., via Proc Filesystem) or insert further malicious components into the build pipelines for a second-order supply chain compromise.[OWASP CICD-SEC-4] As GitHub Actions are often dependent on other GitHub Actions, threat actors may be able to infect a large number of repositories via the compromise of a single Action.[Palo Alto Networks GitHub Actions Worm 2023]
Adversaries may also target the configuration and instruction files consumed by integrated development environments and AI coding agents. Project files such as tasks.json may execute commands when a developer opens or builds a project, while agent skill files (SKILL.md) supply an agent with instructions and resources that it loads on demand and runs with the permissions of the agent process.[Microsoft - Agent Skills Docs][Google Agent Files May 2026][CrowdStrike Threat Hunting Report 2026][Microsoft Contagious Interview March 2026] To encourage downloads, adversaries may publish these files under benign-appearing or typo-squatted names, upload unmodified copies of the genuine skills first so the listings accumulate installs before the content behind them is weaponized, or may place the malicious instructions in a secondary document that the reviewed entry point references.[Zenity Skill Supply Chain August 2026][ESET Agent Skills March 2026] Because these artifacts are natural language or configuration rather than executable code, they may pass registry screening and signature-based scanning.[ESET Agent Skills March 2026][TrendMicro - OpenClaw Skills Distribute ATMOS]
Targeting may be specific to a desired victim set or may be distributed to a broad set of consumers but only move on to additional tactics on specific victims.
Official technique definition · Open in the interactive matrix
Parent and sub-techniques
Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.
Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
File Creation · source-mapped
DC0039 collection page — Scope Sysmon FileCreate (11) to the lab directory; retain the process and file path. Differentiate creation/overwrite if the sensor can.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, path, action, size_bytes.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0039",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"path": "C:\\Lab\\demo.txt",
"action": "create",
"size_bytes": 64
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
File Metadata · source-mapped
DC0059 collection page — Collect scoped file inventory/FIM metadata with hash algorithm and observation time; preserve original timestamps separately from collector time.
Providers and collection configuration
- osquery: Scheduled host-state queries; supported tables and privileges vary by OS. Select a table that actually exposes the required object.
- Linux Audit plus inventory snapshots: Events explain changes; snapshots describe state at collection time.
- Define the inventory query, allowed host set, interval and least-privileged reader. Store a stable asset ID, observation time and collector version.
- Keep successive snapshots and calculate additions, removals and changed attributes. Pair state changes with audit events when available.
- Export collector health and missed-poll counts so a missing snapshot is not misclassified as a missing asset.
Required normalized fields: path, size_bytes, sha256, owner_uid.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0059",
"collector": "illustrative-lab-collector",
"observation": {
"path": "/opt/lab/demo.txt",
"size_bytes": 64,
"sha256": "aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa",
"owner_uid": 1000
}
}
Visibility limits: Snapshots miss short-lived objects and do not identify who caused a change. A generic inventory agent is not guaranteed to expose firmware or kernel-level details.
Module Load · source-mapped
DC0016 collection page — Scope Sysmon ImageLoad (7) to lab processes/paths; retain module hash, signer and destination process. Inventory alone does not prove a module loaded.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, image_loaded, signed, action.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0016",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"image_loaded": "C:\\Lab\\demo.dll",
"signed": false,
"action": "load"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Network Traffic Flow · source-mapped
DC0078 collection page — Collect Zeek conn.log, Suricata flow events or exporter equivalents, including observation point and sampling settings.
Providers and collection configuration
- Zeek: Connection and protocol metadata from traffic visible to the sensor.
- Suricata EVE: Configured flow, alert, DNS, HTTP, TLS and protocol records.
- AWS VPC Flow Logs: IP traffic metadata alternative; no packet payload or DNS answer history, and some traffic is not logged.
- Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.
- Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.
- Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection.
Required normalized fields: source_ip, destination_ip, destination_port, protocol, bytes_sent, bytes_received.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0078",
"collector": "illustrative-lab-collector",
"observation": {
"source_ip": "192.0.2.10",
"destination_ip": "198.51.100.20",
"destination_port": 443,
"protocol": "tcp",
"bytes_sent": 128,
"bytes_received": 512
}
}
Visibility limits: Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.
Process Creation · source-mapped
DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_guid, image, parent_image, command_line, user.
<EventFiltering>
<ProcessCreate onmatch="include">
<Image condition="is">C:\Windows\System32\whoami.exe</Image>
</ProcessCreate>
</EventFiltering>
This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0032",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"image": "C:\\Windows\\System32\\whoami.exe",
"parent_image": "C:\\Windows\\System32\\cmd.exe",
"command_line": "whoami",
"user": "LAB\\analyst"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Process Modification · source-mapped
DC0020 collection page — Use Sysmon ProcessTampering (25) for supported detections and corroborating EDR/memory evidence; it is not a record of every memory write.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, observation, sensor.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0020",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"observation": "process_image_changed",
"sensor": "lab-instrumentation"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Windows Registry Key Modification · source-mapped
DC0063 collection page — Use RegistryEvent 13 for value-set and 14 for rename; compare against intended policy and keep original type/value where available.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- Keep this Windows-specific source separate from other operating systems; there is no direct cross-platform event-ID equivalence.
Required normalized fields: registry_path, event_type, value_type, value.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0063",
"collector": "illustrative-lab-collector",
"observation": {
"registry_path": "HKCU\\Software\\Lab\\Mode",
"event_type": "SetValue",
"value_type": "DWORD",
"value": 1
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.