Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
Command Execution · source-mapped
DC0064 collection page — Collect process command lines and relevant shell/interpreter audit; shell history alone is neither complete nor tamper-resistant.
Providers and collection configuration
- Enable Script Block Logging through the policy/configuration for the installed edition. Forward Microsoft-Windows-PowerShell/Operational for Windows PowerShell, or PowerShellCore/Operational for PowerShell 7.
- Retain script-block ID and fragment ordering alongside process creation. Protect access to collected script text; secrets may be included.
- On Linux, use narrowly scoped Audit execution rules for the lab account and supported architectures, and retain joined SYSCALL/EXECVE/PATH records.
Required normalized fields: interpreter, command_line, actor_uid, session_id.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0064",
"collector": "illustrative-lab-collector",
"observation": {
"interpreter": "/bin/sh",
"command_line": "printf LAB_TELEMETRY_CHECK",
"actor_uid": 1000,
"session_id": "lab-session-1"
}
}
Visibility limits: Script content and process command lines are different signals. Logging may be partial, fragmented, filtered or disabled; never assume a command line reveals everything executed.
File Deletion · source-mapped
DC0040 collection page — Prefer Sysmon FileDeleteDetected (26) when content retention is not needed; FileDelete (23) also archives files and requires a storage/privacy plan.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, path, action, archived.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0040",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"path": "C:\\Lab\\demo.txt",
"action": "delete",
"archived": false
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Process Creation · source-mapped
DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_guid, image, parent_image, command_line, user.
<EventFiltering>
<ProcessCreate onmatch="include">
<Image condition="is">C:\Windows\System32\whoami.exe</Image>
</ProcessCreate>
</EventFiltering>
This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0032",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"image": "C:\\Windows\\System32\\whoami.exe",
"parent_image": "C:\\Windows\\System32\\cmd.exe",
"command_line": "whoami",
"user": "LAB\\analyst"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Scheduled Job Creation · source-mapped
DC0001 collection page — Enable Audit Other Object Access Events for Windows task creation (4698); retain task XML. For cron/systemd timers, collect scheduler definitions and change events separately.
Providers and collection configuration
- Use a lab-only GPO under Computer Configuration → Windows Settings → Security Settings → Advanced Audit Policy Configuration. Enable the specific subcategory named below.
- For object-level auditing, configure a narrow system access control list (SACL) on the test object in addition to policy. Do not audit an entire production directory by default.
- Forward Security events from the responsible host or controller; retain subject and target identities, object identifiers, result and original XML. Confirm effective policy with auditpol /get /category:*.
Required normalized fields: task_name, action, principal, schedule, program.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0001",
"collector": "illustrative-lab-collector",
"observation": {
"task_name": "LabDailyCheck",
"action": "create",
"principal": "lab-user",
"schedule": "daily",
"program": "lab-check.exe"
}
}
Visibility limits: A policy checkbox alone does not guarantee an event. Host role, SACL, success/failure selection and audit policy precedence matter. Directory changes may arrive as multiple records.
User Account Deletion · source-mapped
DC0009 collection page — Enable Audit User Account Management on the responsible Windows host/controller; export equivalent cloud directory audit where applicable.
Providers and collection configuration
- Use a lab-only GPO under Computer Configuration → Windows Settings → Security Settings → Advanced Audit Policy Configuration. Enable the specific subcategory named below.
- For object-level auditing, configure a narrow system access control list (SACL) on the test object in addition to policy. Do not audit an entire production directory by default.
- Forward Security events from the responsible host or controller; retain subject and target identities, object identifiers, result and original XML. Confirm effective policy with auditpol /get /category:*.
Required normalized fields: actor, target_account, action, result.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0009",
"collector": "illustrative-lab-collector",
"observation": {
"actor": "lab-admin",
"target_account": "lab-temp",
"action": "delete",
"result": "success"
}
}
Visibility limits: A policy checkbox alone does not guarantee an event. Host role, SACL, success/failure selection and audit policy precedence matter. Directory changes may arrive as multiple records.
Windows Registry Key Modification · source-mapped
DC0063 collection page — Use RegistryEvent 13 for value-set and 14 for rename; compare against intended policy and keep original type/value where available.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- Keep this Windows-specific source separate from other operating systems; there is no direct cross-platform event-ID equivalence.
Required normalized fields: registry_path, event_type, value_type, value.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0063",
"collector": "illustrative-lab-collector",
"observation": {
"registry_path": "HKCU\\Software\\Lab\\Mode",
"event_type": "SetValue",
"value_type": "DWORD",
"value": 1
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.