Complete technique description
Adversaries may execute commands and perform malicious tasks using AutoIT and AutoHotKey automation scripts. AutoIT and AutoHotkey (AHK) are scripting languages that enable users to automate Windows tasks. These automation scripts can be used to perform a wide variety of actions, such as clicking on buttons, entering text, and opening and closing programs.[AutoIT][AutoHotKey]
Adversaries may use AHK (`.ahk`) and AutoIT (`.au3`) scripts to execute malicious code on a victim's system. For example, adversaries have used for AHK to execute payloads and other modular malware such as keyloggers. Adversaries have also used custom AHK files containing embedded malware as Phishing payloads.[Splunk DarkGate]
These scripts may also be compiled into self-contained executable payloads (`.exe`).[AutoIT][AutoHotKey]
Official technique definition · Open in the interactive matrix
Parent and sub-techniques
Related pages are navigation context. Their tools, rules and lab results are not automatically inherited.
Detection telemetry and configuration
These contracts are selected through exact technique-to-data-component relationships or explicitly labelled planning overrides. Configure a collector at the relevant observation point; a telemetry name alone is not coverage.
File Creation · source-mapped
DC0039 collection page — Scope Sysmon FileCreate (11) to the lab directory; retain the process and file path. Differentiate creation/overwrite if the sensor can.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_id, path, action, size_bytes.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0039",
"collector": "illustrative-lab-collector",
"observation": {
"process_id": 4200,
"path": "C:\\Lab\\demo.txt",
"action": "create",
"size_bytes": 64
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Process Access · source-mapped
DC0035 collection page — Scope Sysmon ProcessAccess (10) to the selected source/target processes and access rights; retain call-trace fields where emitted.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: source_process_id, target_process_id, granted_access, action.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0035",
"collector": "illustrative-lab-collector",
"observation": {
"source_process_id": 4200,
"target_process_id": 4300,
"granted_access": "0x1000",
"action": "open_process"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Process Creation · source-mapped
DC0032 collection page — Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.
Providers and collection configuration
- Microsoft Sysmon: Windows event-based collection; enable the event types needed below.
- Linux Audit: Linux alternative for supported system-call and file events; different semantics and fields.
- Apple Endpoint Security clients: macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.
- On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.
- Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.
- For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms.
Required normalized fields: process_guid, image, parent_image, command_line, user.
<EventFiltering>
<ProcessCreate onmatch="include">
<Image condition="is">C:\Windows\System32\whoami.exe</Image>
</ProcessCreate>
</EventFiltering>
This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>.
Illustrative collection event
Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.
{
"schema": "1200km.telemetry.example.v1",
"synthetic": true,
"timestamp": "2026-09-27T12:00:00Z",
"telemetry_id": "DC0032",
"collector": "illustrative-lab-collector",
"observation": {
"process_guid": "lab-process-001",
"image": "C:\\Windows\\System32\\whoami.exe",
"parent_image": "C:\\Windows\\System32\\cmd.exe",
"command_line": "whoami",
"user": "LAB\\analyst"
}
}
Visibility limits: Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.
Simulation design and documented procedures
Atomic evidence: 1 compatible documented candidates. Live lab status: not run for these imported procedures.
Use disposable lab hosts and test accounts, explicit target allowlists, a clean snapshot, bounded egress and a restore plan. Review every candidate and dependency before any execution.
AutoHotKey script execution
An adversary may attempt to execute malicious script using AutoHotKey software instead of regular terminal like powershell or cmd. A messagebox will be displayed and calculator will popup when the script is executed successfully
Pinned Atomic procedure · 7b5d350e-f758-43cc-a761-8e3f6b052a03 · windows · powershell.
Elevation: not declared required. Cleanup: not declared. This is source documentation, not an execution approval.
script_path: AutoHotKey Script Path (type path; source default PathToAtomicsFolder\T1059.010\src\calc.ahk)autohotkey_path: AutoHotKey Executable File Path (type path; source default $PathToAtomicsFolder\..\ExternalPayloads\ahk\AutoHotKeyU64.exe)
Review the upstream command, dependencies and cleanup at the source link. Source defaults may refer to real infrastructure or destructive actions; they are not authorized targets. No automatic install, prerequisite download or command execution is provided.
1 prerequisite definitions:
- AutoHotKey executable file must exist on disk at the specified location (#{autohotkey_path})
Technique-specific experiment contract
- Choose one procedure implementing T1059.010 AutoHotKey & AutoIT; identify the observable behavior in the source definition, not just its tactic.
- Record exact target, tool/version, inputs, privileges, network limits and approval. Never run an imported default target automatically.
- Enable the collection sources above and verify a benign baseline reaches the detector.
- Run only the approved isolated scenario; capture native events and an independent behavior observable.
- Evaluate the exact rule/model, restore the lab, and preserve configuration, event hashes, alerts, controls and misses.