1200kmSECURITY RESEARCH

1200KM / sigma-rule

Cisco Disabling Logging — Sigma Rule

Sigma rule 9e8f6035-88bf-4a63-96b6-b17c0508257e. Cisco Disabling Logging — Sigma Rule. Turn off logging locally or remote

Rule metadata and linked tags

Author: Austin Clark. Source status: test; severity: high. Source dates: 2019-08-11 / 2023-01-04.

{
  "product": "cisco",
  "service": "aaa"
}

Pinned original Sigma rule · Detection Rule License 1.1

Source SHA-256: 6c7bb7874dd26f17399ad42431d9c624e904e6d896f6d583d36984e231d2758f

Detection logic

Original source YAML. Source-tag agreement is not proof of complete semantic coverage. This rule has not been compiled for a SIEM backend or validated against live telemetry here.

title: Cisco Disabling Logging
id: 9e8f6035-88bf-4a63-96b6-b17c0508257e
status: test
description: Turn off logging locally or remote
references:
    - https://www.cisco.com/en/US/docs/ios/security/command/reference/sec_a2.pdf
author: Austin Clark
date: 2019-08-11
modified: 2023-01-04
tags:
    - attack.defense-impairment
    - attack.t1685
logsource:
    product: cisco
    service: aaa
detection:
    keywords:
        - 'no logging'
        - 'no aaa new-model'
    condition: keywords
falsepositives:
    - Unknown
level: high

Original YAML and metadata in JSON

False positives

  • Unknown

Source references

Connected ecosystem references

Exact source-tagged techniques

Telemetry review

Read the original logsource above, then inspect the linked detection workspaces for technique-level sensor context. No per-rule telemetry equivalence is inferred.