1200kmSECURITY RESEARCH

1200KM / sigma-rule

Potential PSFactoryBuffer COM Hijacking — Sigma Rule

Sigma rule 243380fa-11eb-4141-af92-e14925e77c1b. Potential PSFactoryBuffer COM Hijacking — Sigma Rule. Detects changes to the PSFactory COM InProcServer32 registry. This technique was used by RomCom to create persistence storing a malicious DLL.

Rule metadata and linked tags

Author: BlackBerry Threat Research and Intelligence Team - @Joseliyo_Jstnk. Source status: test; severity: high. Source dates: 2023-06-07 / 2023-08-17.

{
  "category": "registry_set",
  "product": "windows"
}

Pinned original Sigma rule · Detection Rule License 1.1

Source SHA-256: 04430e88a394e4b38ec128b3b8f4cdba13a59c1be641180b18e34e864b72b61f

Detection logic

Original source YAML. Source-tag agreement is not proof of complete semantic coverage. This rule has not been compiled for a SIEM backend or validated against live telemetry here.

title: Potential PSFactoryBuffer COM Hijacking
id: 243380fa-11eb-4141-af92-e14925e77c1b
status: test
description: Detects changes to the PSFactory COM InProcServer32 registry. This technique was used by RomCom to create persistence storing a malicious DLL.
references:
    - https://blogs.blackberry.com/en/2023/06/romcom-resurfaces-targeting-ukraine
    - https://strontic.github.io/xcyclopedia/library/clsid_C90250F3-4D7D-4991-9B69-A5C5BC1C2AE6.html
    - https://www.virustotal.com/gui/file/6d3ab9e729bb03ae8ae3fcd824474c5052a165de6cb4c27334969a542c7b261d/detection
    - https://www.trendmicro.com/en_us/research/23/e/void-rabisu-s-use-of-romcom-backdoor-shows-a-growing-shift-in-th.html
author: BlackBerry Threat Research and Intelligence Team - @Joseliyo_Jstnk
date: 2023-06-07
modified: 2023-08-17
tags:
    - attack.privilege-escalation
    - attack.persistence
    - attack.t1546.015
logsource:
    category: registry_set
    product: windows
detection:
    selection:
        TargetObject|endswith: '\CLSID\{c90250f3-4d7d-4991-9b69-a5c5bc1c2ae6}\InProcServer32\(Default)'
    filter_main:
        Details:
            - '%windir%\System32\ActXPrxy.dll'
            - 'C:\Windows\System32\ActXPrxy.dll'
    condition: selection and not filter_main
falsepositives:
    - Unknown
level: high

Original YAML and metadata in JSON

False positives

  • Unknown

Source references

Connected ecosystem references

Exact source-tagged techniques

Telemetry review

Read the original logsource above, then inspect the linked detection workspaces for technique-level sensor context. No per-rule telemetry equivalence is inferred.

Pinned research references. No browser attack runner, live simulation result or validated detector is asserted. Source mappings and validation limits are preserved. ATT&CK / Atomic provenance · Detection provenance.