1200KM / detection
T0887 Wireless Sniffing — Detection Rules
Detection workspace for T0887 Wireless Sniffing: 0 Sigma sources, 0 Atlas concepts and 0 anomaly models. No live detection validation.
Source-backed rule directory
No reviewed association in this snapshot.
Atlas deterministic concepts
No exact concept selected.
Anomaly models
No exact Atlas model in this snapshot.
ATT&CK analytic guidance
DET0743 Detection of Wireless Sniffing
AN1876 Analytic 1876
Real-time monitoring identifies indirect evidence of passive RF capture on Industrial Control System (ICS) wireless frequencies -- an unassociated device's RF signature detected without a completed association sequence, or a known device's Media Access Control (MAC) address detected from a location/signal strength inconsistent with its registered installation point. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
AN2134 Analytic 2134
Real-time monitoring identifies a process on an Industrial Control System (ICS) Linux asset setting a wireless interface to monitor mode via iwconfig or netlink calls, from a User Identifier (UID) not associated with documented wireless diagnostics. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
AN2272 Analytic 2272
Real-time monitoring identifies a Windows process enabling promiscuous or monitor mode on a wireless adapter on an Industrial Control System (ICS) workstation that is not a designated wireless management station, indicating preparation for wireless interception. OT operational-fidelity gate: Do not alert on novelty, scan/read volume, or enumeration alone. Alert when the source role is not authorized for discovery/polling and the target scope, address/tag range, protocol, or rate deviates from the established operational baseline. Suppress normal SCADA/HMI/historian polling, commissioning, asset inventory, backup, diagnostics, and approved engineering activity.
Connected ecosystem references
Linked tags
Simulation, tools and telemetry
No reviewed association in this snapshot.
Existing anomaly research
Complete technique engineering workbook
Collection configuration and event examples · Anomaly models and design worksheet · Tools and documented software · Simulation procedures · Offline synthetic collection check
Exact source tags are not semantic relevance verdicts. Review actual rule conditions and observation points; imported rules are not backend-compiled or live-validated.
Pinned research references. No browser attack runner or production-validated detector is asserted. Imported procedures remain unvalidated; any bounded lab evidence has its own scope. ATT&CK / Atomic provenance · Detection provenance.