{"source_checked_on":"2026-10-19","schema_version":1,"key":"ics/T1695.002","id":"T1695.002","name":"Ethernet","domain":"ics","reviewed_on":"2026-09-28","source_url":"https://attack.mitre.org/techniques/T1695/002","source_file":{"file":"ics.json","url":"https://raw.githubusercontent.com/mitre-attack/attack-stix-data/20664a889568dce884a1dac0ec7b12ae3a199f51/ics-attack/ics-attack-20.0.json","sha256":"c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183","bytes":5266683},"source_object_sha256":"7034a49154da59de0fe954d4fb54aa769da317cd699c837492b32a2824e5b933","description":"Adversaries may block access to Ethernet communications to prevent instructions or configurations messages from reaching target systems and devices. Ethernet connections allow for communications between IT and OT systems and devices. Blocking Ethernet communications may also block command and reporting messages.(Citation: Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011)\n\nAn adversary may block Ethernet communications by disabling network interfaces, [Service Stop](https://attack.mitre.org/techniques/T0881), or conducting an [Adversary-in-the-Middle](https://attack.mitre.org/techniques/T0830) attack and dropping the network traffic.\n","references":[{"source_name":"mitre-attack","url":"https://attack.mitre.org/techniques/T1695/002","external_id":"T1695.002"},{"source_name":"Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011","description":"Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011 A Taxonomy of Cyber Attacks on SCADA Systems Retrieved. 2018/01/12 ","url":"http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6142258"}],"platforms":["Embedded","Windows","Linux","Network Devices"],"environments":["cloud-hosted-endpoint","ics-ot","network-infrastructure","onprem"],"visibility":"source_mapped","visibility_note":null,"parent":{"key":"ics/T1695","id":"T1695","name":"Block Communications","domain":"ics","level":"technique","parent_id":null,"tactics":["inhibit-response-function"],"platforms":["Embedded","Windows","Linux","Network Devices"],"environments":["cloud-hosted-endpoint","ics-ot","network-infrastructure","onprem"],"page":"techniques/ics/T1695/","constraints":["isolated_authorized_lab","procedure_review_required","telemetry_configuration_required","ot_fixture_and_process_safety_review","potential_disruption_requires_individual_review"],"telemetry_tags":["Application Log Content","Network Traffic Flow","Process Creation","Process/Event Alarm"],"telemetry_references":[{"id":"DC0038","name":"Application Log Content","tag":"Application Log Content","page":"telemetry/DC0038/","kind":"attack_component"},{"id":"DC0078","name":"Network Traffic Flow","tag":"Network Traffic Flow","page":"telemetry/DC0078/","kind":"attack_component"},{"id":"DC0032","name":"Process Creation","tag":"Process Creation","page":"telemetry/DC0032/","kind":"attack_component"},{"id":"DC0109","name":"Process/Event Alarm","tag":"Process/Event Alarm","page":"telemetry/DC0109/","kind":"attack_component"}],"detections":{"page":"detections/ics/T1695/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":4,"live_validated":0},"anomaly_types":[]},"detection_status":"guidance_only","anomaly_tags":[],"tool_tags":[],"tool_references":[],"visibility":"source_mapped","telemetry_status":"mapped","classification":"cannot_simulate_yet","candidate_count":0,"implementation":"not_integrated","methods":[]},"children":[],"telemetry":[{"id":"DC0038","name":"Application Log Content","page":"telemetry/DC0038/","kind":"attack_component","category":"Application and service audit","description":"Application-emitted audit or operational event content.","collection_focus":"Select the application event family required by the detection and document its native schema before normalization.","providers":[{"name":"Application audit logs","scope":"First-party service events and request/result fields; schema is application-specific.","source_id":"otel"},{"name":"OpenTelemetry-compatible log pipelines","scope":"Transport and normalization of emitted records; do not create missing audit instrumentation.","source_id":"otel"}],"configuration":["Enable the application audit category or instrument the owned lab application at the authorization/action boundary.","Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.","Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart."],"configuration_example":null,"required_fields":["service","action","actor","record_count","result"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0038","collector":"illustrative-lab-collector","observation":{"service":"lab-portal","action":"export_requested","actor":"lab-reader","record_count":3,"result":"authorized"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.","sources":[{"id":"otel","title":"OpenTelemetry log data model","url":"https://opentelemetry.io/docs/specs/otel/logs/data-model/"}],"association":"attack_component","anomaly_design":"Per application, client and route: request rate, rare actions, failure ratios and unusual state transitions. Version changes, retries, health probes and seasonal load need separate baselines."},{"id":"DC0108","name":"Device Alarm","page":"telemetry/DC0108/","kind":"attack_component","category":"Industrial operations and physical process","description":"Device-generated alarms about equipment or controller state.","collection_focus":"Subscribe to supported device alarm/audit channels; retain code, severity, source asset and acknowledgement/clear times.","providers":[{"name":"OPC UA audit-capable servers","scope":"Auditable actions where supported and enabled; inspect server conformance and vendor documentation.","source_id":"opc"},{"name":"Controller, HMI and historian exports","scope":"Vendor-specific process values, quality flags, alarms and operational context.","source_id":"ot"},{"name":"Independent lab sensors / safety records","scope":"Physical-effect corroboration, not a universal cybersecurity log format.","source_id":"ot"}],"configuration":["Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.","Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.","Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs."],"configuration_example":null,"required_fields":["asset_id","alarm_code","severity","active"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0108","collector":"illustrative-lab-collector","observation":{"asset_id":"lab-controller-1","alarm_code":"LAB_COMM_LOSS","severity":"warning","active":true}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.","sources":[{"id":"opc","title":"OPC UA audit event model","url":"https://reference.opcfoundation.org/specs/OPC-10000-3/9.5"},{"id":"ot","title":"NIST SP 800-82 Rev. 3: OT security","url":"https://csrc.nist.gov/pubs/sp/800/82/r3/final"}],"association":"attack_component","anomaly_design":"Per asset, operating mode and engineering change window: deviations in command/state sequences, measurement residuals and communication freshness. Use a simulator or approved test rig; never generate hazardous physical effects."},{"id":"DC0032","name":"Process Creation","page":"telemetry/DC0032/","kind":"attack_component","category":"Endpoint activity","description":"Creation of a process with executable, command line, parent and security context.","collection_focus":"Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.","providers":[{"name":"Microsoft Sysmon","scope":"Windows event-based collection; enable the event types needed below.","source_id":"sysmon"},{"name":"Linux Audit","scope":"Linux alternative for supported system-call and file events; different semantics and fields.","source_id":"linux"},{"name":"Apple Endpoint Security clients","scope":"macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.","source_id":"apple"}],"configuration":["On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.","Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.","For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms."],"configuration_example":{"label":"Sysmon filter fragment · merge into the reviewed lab configuration","language":"xml","source_id":"sysmon_config","content":"<EventFiltering>\n  <ProcessCreate onmatch=\"include\">\n    <Image condition=\"is\">C:\\Windows\\System32\\whoami.exe</Image>\n  </ProcessCreate>\n</EventFiltering>","note":"This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>."},"required_fields":["process_guid","image","parent_image","command_line","user"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0032","collector":"illustrative-lab-collector","observation":{"process_guid":"lab-process-001","image":"C:\\Windows\\System32\\whoami.exe","parent_image":"C:\\Windows\\System32\\cmd.exe","command_line":"whoami","user":"LAB\\analyst"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.","sources":[{"id":"sysmon","title":"Microsoft Sysmon events and configuration","url":"https://learn.microsoft.com/en-us/sysinternals/downloads/sysmon"},{"id":"sysmon_config","title":"Microsoft Sysmon configuration files","url":"https://learn.microsoft.com/en-us/windows/security/operating-system-security/sysmon/sysmon-configuration-files"},{"id":"linux","title":"Linux Audit rule configuration","url":"https://www.man7.org/linux/man-pages/man8/auditctl.8.html"},{"id":"apple","title":"Apple Endpoint Security framework for macOS","url":"https://developer.apple.com/documentation/endpointsecurity"},{"id":"process_audit","title":"Microsoft process creation event 4688","url":"https://learn.microsoft.com/en-us/previous-versions/windows/it-pro/windows-10/security/threat-protection/auditing/event-4688"}],"association":"attack_component","anomaly_design":"Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity."}],"detection":{"key":"ics/T1695.002","id":"T1695.002","name":"Ethernet","domain":"ics","platforms":["Embedded","Windows","Linux","Network Devices"],"environments":["cloud-hosted-endpoint","ics-ot","network-infrastructure","onprem"],"source_url":"https://attack.mitre.org/techniques/T1695/002","technique_page":"techniques/ics/T1695.002/","page":"detections/ics/T1695.002/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":4,"live_validated":0},"sigma_rules":[],"atlas_basic":[],"atlas_anomaly":[],"anomaly_types":[],"strategies":[{"id":"DET0911","name":"Detection of Block Ethernet","url":"https://attack.mitre.org/detectionstrategies/DET0911","stix_id":"x-mitre-detection-strategy--feb80c7a-96cd-4300-b344-4d75b176c9cb","relationship_id":"relationship--e56064d9-388d-45b3-99a9-4eeec2e681da","description":"","analytics":[{"id":"AN2054","name":"Analytic 2054","guidance":"Real-time monitoring identifies a Windows network-adapter disable or administrative interface-down event on an ICS gateway or protocol-converter host outside the approved network-maintenance window. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0911#AN2054","platforms":["Windows"],"tuning":[{"field":"ApprovedNMSCIDR","description":"IP ranges authorized for switch configuration changes."},{"field":"ChangeControlWindow","description":"Scheduled maintenance periods during which interface configuration changes are authorized."}],"log_sources":[{"component_id":"DC0038","component":"Application Log Content","name":"WinEventLog:System","channel":"network adapter disabled on Industrial Control Systems (ICS) gateway host by process not in authorized network admins","platforms":["Windows"],"analytic_id":"AN2054","source_url":"https://attack.mitre.org/detectionstrategies/DET0911#AN2054","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0038/"}]},{"id":"AN2165","name":"Analytic 2165","guidance":"Real-time monitoring identifies ip link set down commands on Industrial Control System (ICS) Linux gateway hosts by a User Identifier (UID) not in the authorized net admin UIDs, affecting the device subnet interface. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0911#AN2165","platforms":["Linux"],"tuning":[{"field":"ApprovedNMSCIDR","description":"IP ranges authorized for switch configuration changes."},{"field":"ChangeControlWindow","description":"Scheduled maintenance periods during which interface configuration changes are authorized."}],"log_sources":[{"component_id":"DC0032","component":"Process Creation","name":"auditd:SYSCALL","channel":"Linux Audit SYSCALL/EXECVE/SOCKADDR records (configured audit rule): syscall=execve; ip link command disables an interface on an ICS gateway outside the authorized network-administration baseline","platforms":["Linux"],"analytic_id":"AN2165","source_url":"https://attack.mitre.org/detectionstrategies/DET0911#AN2165","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0032/"}]},{"id":"AN2204","name":"Analytic 2204","guidance":"Real-time monitoring identifies a switch interface transitioning to administratively-down state on a port connected to an Industrial Control System (ICS) field device, from a configuration change source not in the approved network administration list. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0911#AN2204","platforms":["Network Devices"],"tuning":[{"field":"ApprovedNMSCIDR","description":"IP ranges authorized for switch configuration changes."},{"field":"ChangeControlWindow","description":"Scheduled maintenance periods during which interface configuration changes are authorized."}],"log_sources":[{"component_id":"DC0038","component":"Application Log Content","name":"networkdevice:syslog","channel":"interface shutdown command on Industrial Control Systems (ICS) device port from source not in approved Network Management System (NMS) Classless Inter-Domain Routing (CIDR) subnet outside change control window","platforms":["Network Devices"],"analytic_id":"AN2204","source_url":"https://attack.mitre.org/detectionstrategies/DET0911#AN2204","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0038/"}]},{"id":"AN2214","name":"Analytic 2214","guidance":"Real-time monitoring identifies device_ip offline alarm coinciding with switch port admin-down syslog for that port, distinguishing deliberate Ethernet blocking from physical disconnection. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0911#AN2214","platforms":["Embedded"],"tuning":[{"field":"ApprovedNMSCIDR","description":"IP ranges authorized for switch configuration changes."},{"field":"ChangeControlWindow","description":"Scheduled maintenance periods during which interface configuration changes are authorized."}],"log_sources":[{"component_id":"DC0108","component":"Device Alarm","name":"operationaldb:AlarmEvent","channel":"device offline alarm coinciding with switch port admin-down syslog for that port","platforms":["Embedded"],"analytic_id":"AN2214","source_url":"https://attack.mitre.org/detectionstrategies/DET0911#AN2214","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0108/"}]}]}],"telemetry_references":[{"id":"DC0038","name":"Application Log Content","tag":"Application Log Content","page":"telemetry/DC0038/","kind":"attack_component"},{"id":"DC0108","name":"Device Alarm","tag":"Device Alarm","page":"telemetry/DC0108/","kind":"attack_component"},{"id":"DC0032","name":"Process Creation","tag":"Process Creation","page":"telemetry/DC0032/","kind":"attack_component"}],"visibility":"source_mapped","visibility_note":null,"tool_references":[],"related_parent":null,"article_url":"https://1200km.com/articles/read/2026/2026-04-20-malicious-activity-as-a-statistical-signal-a-detection-engineering-analysis-of-anomaly-bas-90df8b6dea12/","validation":{"source_join":"exact_ids","sigma_yaml":"parsed","backend_compilation":"not_run","live_telemetry":"not_run","detection_execution":"not_run"}},"tools":[],"software":[{"id":"S0372","name":"LockerGoga","url":"https://attack.mitre.org/software/S0372","kind":"malware","description":"[LockerGoga](https://attack.mitre.org/software/S0372) had blocked network communications by disabling all the network interfaces on the system via netsh.exe.(Citation: LockerGoga Revisited)(Citation: Kevin Beaumont)(Citation: Detecting LockerGoga)","relationship_id":"relationship--58edd7e0-7b54-4ac5-8e84-81e2dfb03a71","references":[{"source_name":"LockerGoga Revisited","description":"Joe Slowik. (2020, March 17). Spyware Stealer Locker Wiper: LockerGoga Revisited. Retrieved April 22, 2026.","url":"https://www.dragos.com/blog/industry-news/spyware-stealer-locker-wiper-lockergoga-revisited/"},{"source_name":"Kevin Beaumont","description":"Kevin Beaumont   How Lockergoga took down Hydro  ransomware used in targeted attacks aimed at big business Retrieved. 2019/10/16 ","url":"https://doublepulsar.com/how-lockergoga-took-down-hydro-ransomware-used-in-targeted-attacks-aimed-at-big-business-c666551f5880"},{"source_name":"Detecting LockerGoga","description":"Oleg Kolesnikov and Harshvardhan Parashar. (2019, April 30). Detecting LockerGoga Targeted IT/OT Cyber Sabotage/Ransomware Attacks. Retrieved April 22, 2026.","url":"https://www.securonix.com/wp-content/uploads/2021/07/Securonix-Threat-Research-Report-Detecting-LockerGoga.pdf"}]}],"actors":[],"mitigations":[{"id":"M0807","name":"Network Allowlists","url":"https://attack.mitre.org/mitigations/M0807","kind":"course-of-action","description":"Implement network allowlists to minimize network access to only authorized hosts.","relationship_id":"relationship--c6258ef7-95dc-43ef-b0c2-a20011a48699","references":[]},{"id":"M0810","name":"Out-of-Band Communications Channel","url":"https://attack.mitre.org/mitigations/M0810","kind":"course-of-action","description":"Ensure systems and devices have an alternative method for communicating in the event that Ethernet communication channels become unavailable.","relationship_id":"relationship--af5c41cb-063d-42a9-ad54-833bd65477d0","references":[]},{"id":"M0930","name":"Network Segmentation","url":"https://attack.mitre.org/mitigations/M0930","kind":"course-of-action","description":"Segment operational networks to isolate critical systems and devices that do not require broad network access.","relationship_id":"relationship--a3fb7c3c-7064-43d2-849c-2a5893583de9","references":[]}],"candidates":[],"simulation":{"atomic_status":"no_atomic_candidate","lab_execution":"not_run","browser_attack_runner":false,"prerequisites":"Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.","scenario":null},"validation":{"source_identity":"checked_against_pinned_source","relationship_join":"exact_ids_no_inheritance","page_contract":"automated_checks_required","sensor_capture":"not_run","detection_backend":"not_run","adversary_simulation":"not_run","independent_incident_fact_check":"not_performed"},"technique_links":{"T0881":"/ttp-simulation/techniques/ics/T0881/","T0830":"/ttp-simulation/techniques/ics/T0830/","T1695.002":"/ttp-simulation/techniques/ics/T1695.002/"},"synthetic":{"schema":"1200km.ttp.collection-fixture.v1","synthetic":true,"technique_key":"ics/T1695.002","purpose":"Collection/parser contract exercise, NOT a positive example or detection of this TTP.","events":[{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0038","collector":"illustrative-lab-collector","observation":{"service":"lab-portal","action":"export_requested","actor":"lab-reader","record_count":3,"result":"authorized"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0108","collector":"illustrative-lab-collector","observation":{"asset_id":"lab-controller-1","alarm_code":"LAB_COMM_LOSS","severity":"warning","active":true}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0032","collector":"illustrative-lab-collector","observation":{"process_guid":"lab-process-001","image":"C:\\Windows\\System32\\whoami.exe","parent_image":"C:\\Windows\\System32\\cmd.exe","command_line":"whoami","user":"LAB\\analyst"}}]}}