{"source_checked_on":"2026-10-19","schema_version":1,"key":"ics/T1695.001","id":"T1695.001","name":"Serial COM","domain":"ics","reviewed_on":"2026-09-28","source_url":"https://attack.mitre.org/techniques/T1695/001","source_file":{"file":"ics.json","url":"https://raw.githubusercontent.com/mitre-attack/attack-stix-data/20664a889568dce884a1dac0ec7b12ae3a199f51/ics-attack/ics-attack-20.0.json","sha256":"c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183","bytes":5266683},"source_object_sha256":"94109f6e9e3f176b9eab410c7d1c14d0aa442e496b1048ee4a09771eb3925449","description":"Adversaries may block access to serial COM to prevent instructions or configurations from reaching target devices. Serial Communication ports (COM) allow communication with control system devices. Devices can receive command and configuration messages over such serial COM. Devices also use serial COM to send command and reporting messages. Blocking device serial COM may also block command messages and block reporting messages.\n\nA serial to Ethernet converter is often connected to a serial COM to facilitate communication between serial and Ethernet devices. One approach to blocking a serial COM would be to create and hold open a TCP session with the Ethernet side of the converter. A serial to Ethernet converter may have a few ports open to facilitate multiple communications. For example, if there are three serial COM available -- 1, 2 and 3 --, the converter might be listening on the corresponding ports 20001, 20002, and 20003. If a TCP/IP connection is opened with one of these ports and held open, then the port will be unavailable for use by another party. One way the adversary could achieve this would be to initiate a TCP session with the serial to Ethernet converter at 10.0.0.1 via Telnet on serial port 1 with the following command: telnet 10.0.0.1 20001.","references":[{"source_name":"mitre-attack","url":"https://attack.mitre.org/techniques/T1695/001","external_id":"T1695.001"}],"platforms":["Embedded","Windows","Linux","Network Devices"],"environments":["cloud-hosted-endpoint","ics-ot","network-infrastructure","onprem"],"visibility":"source_mapped","visibility_note":null,"parent":{"key":"ics/T1695","id":"T1695","name":"Block Communications","domain":"ics","level":"technique","parent_id":null,"tactics":["inhibit-response-function"],"platforms":["Embedded","Windows","Linux","Network Devices"],"environments":["cloud-hosted-endpoint","ics-ot","network-infrastructure","onprem"],"page":"techniques/ics/T1695/","constraints":["isolated_authorized_lab","procedure_review_required","telemetry_configuration_required","ot_fixture_and_process_safety_review","potential_disruption_requires_individual_review"],"telemetry_tags":["Application Log Content","Network Traffic Flow","Process Creation","Process/Event Alarm"],"telemetry_references":[{"id":"DC0038","name":"Application Log Content","tag":"Application Log Content","page":"telemetry/DC0038/","kind":"attack_component"},{"id":"DC0078","name":"Network Traffic Flow","tag":"Network Traffic Flow","page":"telemetry/DC0078/","kind":"attack_component"},{"id":"DC0032","name":"Process Creation","tag":"Process Creation","page":"telemetry/DC0032/","kind":"attack_component"},{"id":"DC0109","name":"Process/Event Alarm","tag":"Process/Event Alarm","page":"telemetry/DC0109/","kind":"attack_component"}],"detections":{"page":"detections/ics/T1695/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":4,"live_validated":0},"anomaly_types":[]},"detection_status":"guidance_only","anomaly_tags":[],"tool_tags":[],"tool_references":[],"visibility":"source_mapped","telemetry_status":"mapped","classification":"cannot_simulate_yet","candidate_count":0,"implementation":"not_integrated","methods":[]},"children":[],"telemetry":[{"id":"DC0038","name":"Application Log Content","page":"telemetry/DC0038/","kind":"attack_component","category":"Application and service audit","description":"Application-emitted audit or operational event content.","collection_focus":"Select the application event family required by the detection and document its native schema before normalization.","providers":[{"name":"Application audit logs","scope":"First-party service events and request/result fields; schema is application-specific.","source_id":"otel"},{"name":"OpenTelemetry-compatible log pipelines","scope":"Transport and normalization of emitted records; do not create missing audit instrumentation.","source_id":"otel"}],"configuration":["Enable the application audit category or instrument the owned lab application at the authorization/action boundary.","Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.","Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart."],"configuration_example":null,"required_fields":["service","action","actor","record_count","result"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0038","collector":"illustrative-lab-collector","observation":{"service":"lab-portal","action":"export_requested","actor":"lab-reader","record_count":3,"result":"authorized"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.","sources":[{"id":"otel","title":"OpenTelemetry log data model","url":"https://opentelemetry.io/docs/specs/otel/logs/data-model/"}],"association":"attack_component","anomaly_design":"Per application, client and route: request rate, rare actions, failure ratios and unusual state transitions. Version changes, retries, health probes and seasonal load need separate baselines."},{"id":"DC0061","name":"File Modification","page":"telemetry/DC0061/","kind":"attack_component","category":"Endpoint activity","description":"Changes to file data or attributes.","collection_focus":"Use file-integrity monitoring or scoped OS file-write auditing for general changes. Sysmon 2 records creation-time changes; it is not a general file-write event.","providers":[{"name":"Microsoft Sysmon","scope":"Windows event-based collection; enable the event types needed below.","source_id":"sysmon"},{"name":"Linux Audit","scope":"Linux alternative for supported system-call and file events; different semantics and fields.","source_id":"linux"},{"name":"Apple Endpoint Security clients","scope":"macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.","source_id":"apple"}],"configuration":["On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.","Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.","For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms."],"configuration_example":null,"required_fields":["path","attribute","before","after"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0061","collector":"illustrative-lab-collector","observation":{"path":"C:\\Lab\\demo.txt","attribute":"content_hash","before":"aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa","after":"bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.","sources":[{"id":"sysmon","title":"Microsoft Sysmon events and configuration","url":"https://learn.microsoft.com/en-us/sysinternals/downloads/sysmon"},{"id":"sysmon_config","title":"Microsoft Sysmon configuration files","url":"https://learn.microsoft.com/en-us/windows/security/operating-system-security/sysmon/sysmon-configuration-files"},{"id":"linux","title":"Linux Audit rule configuration","url":"https://www.man7.org/linux/man-pages/man8/auditctl.8.html"},{"id":"apple","title":"Apple Endpoint Security framework for macOS","url":"https://developer.apple.com/documentation/endpointsecurity"},{"id":"process_audit","title":"Microsoft process creation event 4688","url":"https://learn.microsoft.com/en-us/previous-versions/windows/it-pro/windows-10/security/threat-protection/auditing/event-4688"}],"association":"attack_component","anomaly_design":"Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity."},{"id":"DC0109","name":"Process/Event Alarm","page":"telemetry/DC0109/","kind":"attack_component","category":"Industrial operations and physical process","description":"Alarms raised by process conditions or operational events.","collection_focus":"Export alarm/event history with setpoint context and lifecycle transitions; retain suppressed/shelved state when provided.","providers":[{"name":"OPC UA audit-capable servers","scope":"Auditable actions where supported and enabled; inspect server conformance and vendor documentation.","source_id":"opc"},{"name":"Controller, HMI and historian exports","scope":"Vendor-specific process values, quality flags, alarms and operational context.","source_id":"ot"},{"name":"Independent lab sensors / safety records","scope":"Physical-effect corroboration, not a universal cybersecurity log format.","source_id":"ot"}],"configuration":["Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.","Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.","Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs."],"configuration_example":null,"required_fields":["tag","alarm","threshold","value","acknowledged"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0109","collector":"illustrative-lab-collector","observation":{"tag":"LAB.TankLevel","alarm":"high_level","threshold":80,"value":82,"acknowledged":false}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.","sources":[{"id":"opc","title":"OPC UA audit event model","url":"https://reference.opcfoundation.org/specs/OPC-10000-3/9.5"},{"id":"ot","title":"NIST SP 800-82 Rev. 3: OT security","url":"https://csrc.nist.gov/pubs/sp/800/82/r3/final"}],"association":"attack_component","anomaly_design":"Per asset, operating mode and engineering change window: deviations in command/state sequences, measurement residuals and communication freshness. Use a simulator or approved test rig; never generate hazardous physical effects."},{"id":"DC0063","name":"Windows Registry Key Modification","page":"telemetry/DC0063/","kind":"attack_component","category":"Endpoint activity","description":"Registry value changes or registry object renames.","collection_focus":"Use RegistryEvent 13 for value-set and 14 for rename; compare against intended policy and keep original type/value where available.","providers":[{"name":"Microsoft Sysmon","scope":"Windows event-based collection; enable the event types needed below.","source_id":"sysmon"}],"configuration":["On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.","Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.","Keep this Windows-specific source separate from other operating systems; there is no direct cross-platform event-ID equivalence."],"configuration_example":null,"required_fields":["registry_path","event_type","value_type","value"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0063","collector":"illustrative-lab-collector","observation":{"registry_path":"HKCU\\Software\\Lab\\Mode","event_type":"SetValue","value_type":"DWORD","value":1}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.","sources":[{"id":"sysmon","title":"Microsoft Sysmon events and configuration","url":"https://learn.microsoft.com/en-us/sysinternals/downloads/sysmon"},{"id":"sysmon_config","title":"Microsoft Sysmon configuration files","url":"https://learn.microsoft.com/en-us/windows/security/operating-system-security/sysmon/sysmon-configuration-files"}],"association":"attack_component","anomaly_design":"Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity."}],"detection":{"key":"ics/T1695.001","id":"T1695.001","name":"Serial COM","domain":"ics","platforms":["Embedded","Windows","Linux","Network Devices"],"environments":["cloud-hosted-endpoint","ics-ot","network-infrastructure","onprem"],"source_url":"https://attack.mitre.org/techniques/T1695/001","technique_page":"techniques/ics/T1695.001/","page":"detections/ics/T1695.001/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":4,"live_validated":0},"sigma_rules":[],"atlas_basic":[],"atlas_anomaly":[],"anomaly_types":[],"strategies":[{"id":"DET0797","name":"Detection of Block Serial COM","url":"https://attack.mitre.org/detectionstrategies/DET0797","stix_id":"x-mitre-detection-strategy--4ea060f9-f6fc-4122-9544-70afd567ea10","relationship_id":"relationship--28d4feb4-7a87-4376-8401-d579f830472b","description":"","analytics":[{"id":"AN1929","name":"Analytic 1929","guidance":"Real-time monitoring identifies a loss of communication with serially-connected field devices correlated with a configuration change event on the serial-to-Ethernet gateway. Documented in the 2015 Ukraine attack, where Sandworm used malicious firmware to render serial-to-Ethernet converters inoperable. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0797#AN1929","platforms":["Embedded"],"tuning":[{"field":"SerialBlockCorrelationWindow","description":"Time window within which a serial gateway configuration change and subsequent device communication loss are considered causally connected."}],"log_sources":[{"component_id":"DC0109","component":"Process/Event Alarm","name":"operationaldb:AlarmEvent","channel":"device_ip communication-loss alarm within serial block correlation window of a flagged serial gateway configuration change","platforms":["Embedded"],"analytic_id":"AN1929","source_url":"https://attack.mitre.org/detectionstrategies/DET0797#AN1929","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0109/"},{"component_id":"DC0038","component":"Application Log Content","name":"serialgw:syslog","channel":"serial port parameter change (baud rate, parity, port disable) without corresponding change ticket reference","platforms":["Embedded"],"analytic_id":"AN1929","source_url":"https://attack.mitre.org/detectionstrategies/DET0797#AN1929","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0038/"}]},{"id":"AN2119","name":"Analytic 2119","guidance":"Real-time monitoring identifies writes to serial device configuration files or `stty` commands changing serial port parameters on Industrial Control System (ICS) Linux gateway hosts from a User Identifier (UID) not associated with authorized serial port management. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0797#AN2119","platforms":["Linux"],"tuning":[{"field":"SerialBlockCorrelationWindow","description":"Time window within which a serial gateway configuration change and subsequent device communication loss are considered causally connected."}],"log_sources":[{"component_id":"DC0061","component":"File Modification","name":"auditd:SYSCALL+PATH","channel":"Linux Audit SYSCALL+PATH records: PATH record shows modification of a serial-device configuration file by a UID not in the authorized serial-administration set","platforms":["Linux"],"analytic_id":"AN2119","source_url":"https://attack.mitre.org/detectionstrategies/DET0797#AN2119","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0061/"}]},{"id":"AN2200","name":"Analytic 2200","guidance":"Real-time monitoring identifies configuration changes to serial server or terminal server devices that alter serial port parameters for ports connected to field devices. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0797#AN2200","platforms":["Network Devices"],"tuning":[{"field":"SerialBlockCorrelationWindow","description":"Time window within which a serial gateway configuration change and subsequent device communication loss are considered causally connected."}],"log_sources":[{"component_id":"DC0038","component":"Application Log Content","name":"networkdevice:syslog","channel":"serial server configuration change altering port parameters for field device ports from source not in approved Network Management System (NMS) Classless Inter-Domain Routing (CIDR) subnet","platforms":["Network Devices"],"analytic_id":"AN2200","source_url":"https://attack.mitre.org/detectionstrategies/DET0797#AN2200","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0038/"}]},{"id":"AN2280","name":"Analytic 2280","guidance":"Real-time monitoring identifies Windows serial port configuration changes on Industrial Control System (ICS) gateway hosts that would disrupt communication with serial field devices. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0797#AN2280","platforms":["Windows"],"tuning":[{"field":"SerialBlockCorrelationWindow","description":"Time window within which a serial gateway configuration change and subsequent device communication loss are considered causally connected."}],"log_sources":[{"component_id":"DC0063","component":"Windows Registry Key Modification","name":"WinEventLog:Sysmon","channel":"EventCode=13 to Communication (COM) port configuration key by process not in authorized serial port management tools","platforms":["Windows"],"analytic_id":"AN2280","source_url":"https://attack.mitre.org/detectionstrategies/DET0797#AN2280","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0063/"}]}]}],"telemetry_references":[{"id":"DC0038","name":"Application Log Content","tag":"Application Log Content","page":"telemetry/DC0038/","kind":"attack_component"},{"id":"DC0061","name":"File Modification","tag":"File Modification","page":"telemetry/DC0061/","kind":"attack_component"},{"id":"DC0109","name":"Process/Event Alarm","tag":"Process/Event Alarm","page":"telemetry/DC0109/","kind":"attack_component"},{"id":"DC0063","name":"Windows Registry Key Modification","tag":"Windows Registry Key Modification","page":"telemetry/DC0063/","kind":"attack_component"}],"visibility":"source_mapped","visibility_note":null,"tool_references":[],"related_parent":null,"article_url":"https://1200km.com/articles/read/2026/2026-04-20-malicious-activity-as-a-statistical-signal-a-detection-engineering-analysis-of-anomaly-bas-90df8b6dea12/","validation":{"source_join":"exact_ids","sigma_yaml":"parsed","backend_compilation":"not_run","live_telemetry":"not_run","detection_execution":"not_run"}},"tools":[],"software":[{"id":"S0604","name":"Industroyer","url":"https://attack.mitre.org/software/S0604","kind":"malware","description":"In [Industroyer](https://attack.mitre.org/software/S0604) the first COM port from the configuration file is used for the actual communication and the two other COM ports are just opened to prevent other processes accessing them. Thus, the IEC 101 payload component is able to take over and maintain control of the RTU device. (Citation: Anton Cherepanov, ESET June 2017)","relationship_id":"relationship--7c7777a0-f96a-414c-b294-e9f0744bf8b8","references":[{"source_name":"Anton Cherepanov, ESET June 2017","description":"Anton Cherepanov, ESET 2017, June 12 Win32/Industroyer: A new threat for industrial control systems Retrieved. 2017/09/15 ","url":"https://www.welivesecurity.com/wp-content/uploads/2017/06/Win32_Industroyer.pdf"}]}],"actors":[],"mitigations":[{"id":"M0807","name":"Network Allowlists","url":"https://attack.mitre.org/mitigations/M0807","kind":"course-of-action","description":"Implement network allowlists to minimize serial comm port access to only authorized hosts, such as comm servers and RTUs.\n","relationship_id":"relationship--6f815d4c-0512-4d92-bcdf-068034233048","references":[]},{"id":"M0810","name":"Out-of-Band Communications Channel","url":"https://attack.mitre.org/mitigations/M0810","kind":"course-of-action","description":"Ensure devices have an alternative method for communicating in the event that a valid COM port is unavailable.\n","relationship_id":"relationship--0105c4f6-a34f-4e0e-964b-a7d108ea3e08","references":[]},{"id":"M0930","name":"Network Segmentation","url":"https://attack.mitre.org/mitigations/M0930","kind":"course-of-action","description":"Restrict unauthorized devices from accessing serial comm ports.\n","relationship_id":"relationship--4b44a657-11cc-45bc-b096-f32e58a70036","references":[]}],"candidates":[],"simulation":{"atomic_status":"no_atomic_candidate","lab_execution":"not_run","browser_attack_runner":false,"prerequisites":"Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.","scenario":null},"validation":{"source_identity":"checked_against_pinned_source","relationship_join":"exact_ids_no_inheritance","page_contract":"automated_checks_required","sensor_capture":"not_run","detection_backend":"not_run","adversary_simulation":"not_run","independent_incident_fact_check":"not_performed"},"technique_links":{"T1695.001":"/ttp-simulation/techniques/ics/T1695.001/"},"synthetic":{"schema":"1200km.ttp.collection-fixture.v1","synthetic":true,"technique_key":"ics/T1695.001","purpose":"Collection/parser contract exercise, NOT a positive example or detection of this TTP.","events":[{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0038","collector":"illustrative-lab-collector","observation":{"service":"lab-portal","action":"export_requested","actor":"lab-reader","record_count":3,"result":"authorized"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0061","collector":"illustrative-lab-collector","observation":{"path":"C:\\Lab\\demo.txt","attribute":"content_hash","before":"aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa","after":"bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0109","collector":"illustrative-lab-collector","observation":{"tag":"LAB.TankLevel","alarm":"high_level","threshold":80,"value":82,"acknowledged":false}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0063","collector":"illustrative-lab-collector","observation":{"registry_path":"HKCU\\Software\\Lab\\Mode","event_type":"SetValue","value_type":"DWORD","value":1}}]}}