{"source_checked_on":"2026-10-19","schema_version":1,"key":"ics/T1694.001","id":"T1694.001","name":"Default Credentials","domain":"ics","reviewed_on":"2026-09-28","source_url":"https://attack.mitre.org/techniques/T1694/001","source_file":{"file":"ics.json","url":"https://raw.githubusercontent.com/mitre-attack/attack-stix-data/20664a889568dce884a1dac0ec7b12ae3a199f51/ics-attack/ics-attack-20.0.json","sha256":"c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183","bytes":5266683},"source_object_sha256":"54412d8a508439522d1f45c91c11412e42b71889cd5647090d41d753f7e8c5bb","description":"Adversaries may leverage manufacturer or supplier set default credentials on control system devices. These default credentials may have administrative permissions and may be necessary for initial configuration of the device. It is general best practice to change the passwords for these accounts as soon as possible, but some manufacturers may have devices that have passwords or usernames that cannot be changed.(Citation: Keith Stouffer May 2015)\n\nDefault credentials are normally documented in an instruction manual that is either packaged with the device, published online through official means, or published online through unofficial means. Adversaries may leverage default credentials that have not been properly modified or disabled.","references":[{"source_name":"mitre-attack","url":"https://attack.mitre.org/techniques/T1694/001","external_id":"T1694.001"},{"source_name":"Keith Stouffer May 2015","description":"Keith Stouffer 2015, May Guide to Industrial Control Systems (ICS) Security Retrieved. 2018/03/28 ","url":"https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-82r2.pdf"}],"platforms":["Embedded","Windows","Linux","Network Devices"],"environments":["cloud-hosted-endpoint","ics-ot","network-infrastructure","onprem"],"visibility":"source_mapped","visibility_note":null,"parent":{"key":"ics/T1694","id":"T1694","name":"Insecure Credentials","domain":"ics","level":"technique","parent_id":null,"tactics":["lateral-movement","persistence"],"platforms":["Embedded","Windows","Linux","Network Devices"],"environments":["cloud-hosted-endpoint","ics-ot","network-infrastructure","onprem"],"page":"techniques/ics/T1694/","constraints":["isolated_authorized_lab","procedure_review_required","telemetry_configuration_required","ot_fixture_and_process_safety_review"],"telemetry_tags":["Logon Session Creation","Network Traffic Content","User Account Authentication"],"telemetry_references":[{"id":"DC0067","name":"Logon Session Creation","tag":"Logon Session Creation","page":"telemetry/DC0067/","kind":"attack_component"},{"id":"DC0085","name":"Network Traffic Content","tag":"Network Traffic Content","page":"telemetry/DC0085/","kind":"attack_component"},{"id":"DC0002","name":"User Account Authentication","tag":"User Account Authentication","page":"telemetry/DC0002/","kind":"attack_component"}],"detections":{"page":"detections/ics/T1694/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":4,"live_validated":0},"anomaly_types":[]},"detection_status":"guidance_only","anomaly_tags":[],"tool_tags":[],"tool_references":[],"visibility":"source_mapped","telemetry_status":"mapped","classification":"cannot_simulate_yet","candidate_count":0,"implementation":"not_integrated","methods":[]},"children":[],"telemetry":[{"id":"DC0067","name":"Logon Session Creation","page":"telemetry/DC0067/","kind":"attack_component","category":"Windows and directory audit","description":"Creation of a logon session with account and logon-type context.","collection_focus":"Enable Audit Logon and collect successful session creation on the receiving host; join session/logon IDs rather than only account names.","providers":[{"name":"Windows Security auditing","scope":"Policy-dependent account, object, task and logon records on the host that performs the operation.","source_id":"audit"}],"configuration":["Use a lab-only GPO under Computer Configuration → Windows Settings → Security Settings → Advanced Audit Policy Configuration. Enable the specific subcategory named below.","For object-level auditing, configure a narrow system access control list (SACL) on the test object in addition to policy. Do not audit an entire production directory by default.","Forward Security events from the responsible host or controller; retain subject and target identities, object identifiers, result and original XML. Confirm effective policy with auditpol /get /category:*."],"configuration_example":null,"required_fields":["account","logon_id","logon_type","source_ip"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0067","collector":"illustrative-lab-collector","observation":{"account":"LAB\\analyst","logon_id":"0x12345","logon_type":3,"source_ip":"192.0.2.10"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"A policy checkbox alone does not guarantee an event. Host role, SACL, success/failure selection and audit policy precedence matter. Directory changes may arrive as multiple records.","sources":[{"id":"audit","title":"Microsoft advanced security audit policy","url":"https://learn.microsoft.com/en-us/previous-versions/windows/it-pro/windows-10/security/threat-protection/auditing/advanced-security-audit-policy-settings"},{"id":"ad","title":"Microsoft Audit Directory Service Changes","url":"https://learn.microsoft.com/windows/security/threat-protection/auditing/audit-directory-service-changes"},{"id":"task","title":"Microsoft scheduled-task creation event 4698","url":"https://learn.microsoft.com/en-us/previous-versions/windows/it-pro/windows-10/security/threat-protection/auditing/event-4698"}],"association":"attack_component","anomaly_design":"Per principal, host and object: unusual access/request rates, new principal-object relationships, and changes outside approved administration windows. Control for service accounts and scheduled directory maintenance."},{"id":"DC0085","name":"Network Traffic Content","page":"telemetry/DC0085/","kind":"attack_component","category":"Network and protocol telemetry","description":"Packet or decoded application-protocol content visible at a network sensor.","collection_focus":"Scope approved packet capture/protocol content collection to the lab flow; retain capture provenance and truncation indicators.","providers":[{"name":"Zeek","scope":"Connection and protocol metadata from traffic visible to the sensor.","source_id":"zeek"},{"name":"Suricata EVE","scope":"Configured flow, alert, DNS, HTTP, TLS and protocol records.","source_id":"suricata"}],"configuration":["Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.","Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.","Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection."],"configuration_example":null,"required_fields":["flow_id","protocol","method","path","payload_excerpt"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0085","collector":"illustrative-lab-collector","observation":{"flow_id":"lab-flow-1","protocol":"http","method":"GET","path":"/lab-check","payload_excerpt":"LAB_TELEMETRY_CHECK"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.","sources":[{"id":"zeek","title":"Zeek protocol and connection logs","url":"https://docs.zeek.org/en/current/reference/logs/index.html"},{"id":"zeek_start","title":"Zeek capture setup","url":"https://docs.zeek.org/en/current/quickstart.html"},{"id":"suricata","title":"Suricata EVE JSON output","url":"https://docs.suricata.io/en/latest/output/eve/eve-json-output.html"}],"association":"attack_component","anomaly_design":"Per source and observation point: connection rate, destination-host/port fan-out, response/failure ratio and previously unseen destinations. Compare equivalent time windows; separate authorized scanners, NAT and sampling effects."},{"id":"DC0002","name":"User Account Authentication","page":"telemetry/DC0002/","kind":"attack_component","category":"Identity and SaaS","description":"Authentication attempts and outcomes for a user or workload account.","collection_focus":"Collect successful and failed sign-ins, authentication method, application and conditional-access context; distinguish account validation from session creation.","providers":[{"name":"Microsoft Entra sign-in logs","scope":"Interactive, non-interactive and workload sign-in contexts, subject to tenant features and access.","source_id":"entra"},{"name":"Cloud identity service audit","scope":"Issuer-side credential and administrative events where the service supports them.","source_id":"cloudtrail"},{"name":"Application audit instrumentation","scope":"Application-side use of identities and sessions; design fields without raw tokens.","source_id":"otel"}],"configuration":["Enable/export the required identity sign-in and audit categories from the lab tenant to a protected destination. Document license, role and retention requirements.","Correlate issuance or administrative changes with later sign-ins using non-secret credential IDs, application IDs, user IDs and correlation IDs.","Exclude passwords, bearer tokens, cookies and private keys. Record success, failure, authentication context and application result separately."],"configuration_example":null,"required_fields":["account","application","result","reason","source_ip"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0002","collector":"illustrative-lab-collector","observation":{"account":"analyst@example.test","application":"lab-portal","result":"failure","reason":"invalid_credential","source_ip":"192.0.2.10"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"A token creation record is not evidence of token use; a sign-in is not a complete record of every resource access. Some provider-side data is unavailable to the customer.","sources":[{"id":"entra","title":"Microsoft Entra sign-in logs","url":"https://learn.microsoft.com/en-us/entra/identity/monitoring-health/concept-sign-ins"},{"id":"cloudtrail","title":"AWS CloudTrail event categories","url":"https://docs.aws.amazon.com/awscloudtrail/latest/userguide/cloudtrail-events.html"},{"id":"otel","title":"OpenTelemetry log data model","url":"https://opentelemetry.io/docs/specs/otel/logs/data-model/"}],"association":"attack_component","anomaly_design":"Per identity and application: first-seen clients/resources, changes in authentication failures and session patterns, and unusual permission changes. Separate automation, travel, shared egress and identity-provider policy changes."}],"detection":{"key":"ics/T1694.001","id":"T1694.001","name":"Default Credentials","domain":"ics","platforms":["Embedded","Windows","Linux","Network Devices"],"environments":["cloud-hosted-endpoint","ics-ot","network-infrastructure","onprem"],"source_url":"https://attack.mitre.org/techniques/T1694/001","technique_page":"techniques/ics/T1694.001/","page":"detections/ics/T1694.001/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":4,"live_validated":0},"sigma_rules":[],"atlas_basic":[],"atlas_anomaly":[],"anomaly_types":[],"strategies":[{"id":"DET0756","name":"Detection of Default Credentials","url":"https://attack.mitre.org/detectionstrategies/DET0756","stix_id":"x-mitre-detection-strategy--b04e83cc-8ace-4880-8953-7ce55eb8c427","relationship_id":"relationship--085ccfd8-ef5f-41cb-abc7-be5330c60f4e","description":"","analytics":[{"id":"AN1888","name":"Analytic 1888","guidance":"Real-time monitoring identifies successful authentication to an Industrial Control System (ICS) application such as a Human-Machine Interface (HMI), historian, Supervisory Control and Data Acquisition (SCADA) server using credentials matching known default vendor passwords, from a logon source not associated with any authorized user. OT operational-fidelity gate: Alert only when the account/device/session violates the approved identity + source host/jump path/zone policy and is corroborated by access to a protected OT asset, execution, configuration change, or another security-relevant follow-on event. Suppress approved shift activity, vendor support, break-glass use, commissioning, and documented remote-access windows.","url":"https://attack.mitre.org/detectionstrategies/DET0756#AN1888","platforms":["Windows"],"tuning":[{"field":"DefaultVendorCredentialList","description":"Documented default username/password combinations for all device models in the environment."},{"field":"EngineeringWorkstationList","description":"IP allowlist of legitimate authentication sources."}],"log_sources":[{"component_id":"DC0067","component":"Logon Session Creation","name":"WinEventLog:Security","channel":"Windows Security Event ID 4624/4625: EventCode=4624 for account matching default vendor credential list from source not in approved host list","platforms":["Windows"],"analytic_id":"AN1888","source_url":"https://attack.mitre.org/detectionstrategies/DET0756#AN1888","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0067/"}]},{"id":"AN2193","name":"Analytic 2193","guidance":"Real-time monitoring identifies authentication attempts against Industrial Control System (ICS) network device management interfaces using well-known default vendor credentials from source Internet Protocol (IP) addresses not in the approved Network Management System (NMS) Classless Inter-Domain Routing (CIDR) subnet range. OT operational-fidelity gate: Alert only when the account/device/session violates the approved identity + source host/jump path/zone policy and is corroborated by access to a protected OT asset, execution, configuration change, or another security-relevant follow-on event. Suppress approved shift activity, vendor support, break-glass use, commissioning, and documented remote-access windows.","url":"https://attack.mitre.org/detectionstrategies/DET0756#AN2193","platforms":["Network Devices"],"tuning":[{"field":"DefaultVendorCredentialList","description":"Documented default username/password combinations for all device models in the environment."},{"field":"EngineeringWorkstationList","description":"IP allowlist of legitimate authentication sources."}],"log_sources":[{"component_id":"DC0002","component":"User Account Authentication","name":"networkdevice:syslog","channel":"Device authentication/audit log: successful authentication using a vendor-default or prohibited account from a non-approved management source","platforms":["Network Devices"],"analytic_id":"AN2193","source_url":"https://attack.mitre.org/detectionstrategies/DET0756#AN2193","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0002/"}]},{"id":"AN2218","name":"Analytic 2218","guidance":"Real-time monitoring identifies successful authentication to a field device using credentials matching documented vendor-default values, from a source not in the approved access list. OT operational-fidelity gate: Alert only when the account/device/session violates the approved identity + source host/jump path/zone policy and is corroborated by access to a protected OT asset, execution, configuration change, or another security-relevant follow-on event. Suppress approved shift activity, vendor support, break-glass use, commissioning, and documented remote-access windows.","url":"https://attack.mitre.org/detectionstrategies/DET0756#AN2218","platforms":["Embedded"],"tuning":[{"field":"DefaultVendorCredentialList","description":"Documented default username/password combinations for all device models in the environment."},{"field":"EngineeringWorkstationList","description":"IP allowlist of legitimate authentication sources."}],"log_sources":[{"component_id":"DC0085","component":"Network Traffic Content","name":"NSM:Content","channel":"authentication success using credential matching default vendor credential list from source not in engineering workstation list","platforms":["Embedded"],"analytic_id":"AN2218","source_url":"https://attack.mitre.org/detectionstrategies/DET0756#AN2218","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0085/"}]},{"id":"AN2255","name":"Analytic 2255","guidance":"Real-time monitoring identifies successful Secure Shell (SSH) or application authentication using credentials matching known default vendor passwords on Industrial Control System (ICS) Linux assets. OT operational-fidelity gate: Alert only when the account/device/session violates the approved identity + source host/jump path/zone policy and is corroborated by access to a protected OT asset, execution, configuration change, or another security-relevant follow-on event. Suppress approved shift activity, vendor support, break-glass use, commissioning, and documented remote-access windows.","url":"https://attack.mitre.org/detectionstrategies/DET0756#AN2255","platforms":["Linux"],"tuning":[{"field":"DefaultVendorCredentialList","description":"Documented default username/password combinations for all device models in the environment."},{"field":"EngineeringWorkstationList","description":"IP allowlist of legitimate authentication sources."}],"log_sources":[{"component_id":"DC0067","component":"Logon Session Creation","name":"syslog:auth","channel":"sshd Accepted for username matching default vendor credential list from source not in approved admin Classless Inter-Domain Routing (CIDR) subnet","platforms":["Linux"],"analytic_id":"AN2255","source_url":"https://attack.mitre.org/detectionstrategies/DET0756#AN2255","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0067/"}]}]}],"telemetry_references":[{"id":"DC0067","name":"Logon Session Creation","tag":"Logon Session Creation","page":"telemetry/DC0067/","kind":"attack_component"},{"id":"DC0085","name":"Network Traffic Content","tag":"Network Traffic Content","page":"telemetry/DC0085/","kind":"attack_component"},{"id":"DC0002","name":"User Account Authentication","tag":"User Account Authentication","page":"telemetry/DC0002/","kind":"attack_component"}],"visibility":"source_mapped","visibility_note":null,"tool_references":[],"related_parent":null,"article_url":"https://1200km.com/articles/read/2026/2026-04-20-malicious-activity-as-a-statistical-signal-a-detection-engineering-analysis-of-anomaly-bas-90df8b6dea12/","validation":{"source_join":"exact_ids","sigma_yaml":"parsed","backend_compilation":"not_run","live_telemetry":"not_run","detection_execution":"not_run"}},"tools":[],"software":[],"actors":[{"id":"G1027","name":"CyberAv3ngers","url":"https://attack.mitre.org/groups/G1027","kind":"intrusion-set","description":"During the [2026 Iranian Water Campaign](https://attack.mitre.org/campaigns/C0065), [CyberAv3ngers](https://attack.mitre.org/groups/G1027) accessed internet-accessible equipment using default credentials.(Citation: Tenable Minnesota Water Utilities)(Citation: Dispel Iran Water Utilities) ","relationship_id":"relationship--76c3caa4-bc2a-437d-9826-3d32a78ff76a","references":[{"source_name":"Dispel Iran Water Utilities","description":"Connor Hazen. (2026, July 31). When 30 Water Utilities Get Hit in 48 Hours, the Lesson Isn’t “Better Malware” — It’s “No Front Door” . Retrieved September 26, 2026.","url":"https://dispel.com/blog/minnesota-water-utility-attacks-secure-remote-access-ot"},{"source_name":"Tenable Minnesota Water Utilities","description":"Research Special Operations. (2026, July 28). Coordinated \"cyberattack\" on U.S. water utilities: What you need to know. Retrieved September 26, 2026.","url":"https://www.tenable.com/blog/coordinated-cyberattack-on-minnesota-water-utilities-what-you-need-to-know"}]}],"mitigations":[{"id":"M0801","name":"Access Management","url":"https://attack.mitre.org/mitigations/M0801","kind":"course-of-action","description":"Ensure embedded controls and network devices are protected through access management, as these devices often have unknown default accounts which could be used to gain unauthorized access.\n","relationship_id":"relationship--23f33619-c64e-4999-85c1-b5c88e570e46","references":[]},{"id":"M0927","name":"Password Policies","url":"https://attack.mitre.org/mitigations/M0927","kind":"course-of-action","description":"Review vendor documents and security alerts for potentially unknown or overlooked default credentials within existing devices.\n","relationship_id":"relationship--096e7743-c090-4386-a759-d749f00bae61","references":[]}],"candidates":[],"simulation":{"atomic_status":"no_atomic_candidate","lab_execution":"not_run","browser_attack_runner":false,"prerequisites":"Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.","scenario":null},"validation":{"source_identity":"checked_against_pinned_source","relationship_join":"exact_ids_no_inheritance","page_contract":"automated_checks_required","sensor_capture":"not_run","detection_backend":"not_run","adversary_simulation":"not_run","independent_incident_fact_check":"not_performed"},"technique_links":{"T1694.001":"/ttp-simulation/techniques/ics/T1694.001/"},"synthetic":{"schema":"1200km.ttp.collection-fixture.v1","synthetic":true,"technique_key":"ics/T1694.001","purpose":"Collection/parser contract exercise, NOT a positive example or detection of this TTP.","events":[{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0067","collector":"illustrative-lab-collector","observation":{"account":"LAB\\analyst","logon_id":"0x12345","logon_type":3,"source_ip":"192.0.2.10"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0085","collector":"illustrative-lab-collector","observation":{"flow_id":"lab-flow-1","protocol":"http","method":"GET","path":"/lab-check","payload_excerpt":"LAB_TELEMETRY_CHECK"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0002","collector":"illustrative-lab-collector","observation":{"account":"analyst@example.test","application":"lab-portal","result":"failure","reason":"invalid_credential","source_ip":"192.0.2.10"}}]}}