{"source_checked_on":"2026-10-19","schema_version":1,"key":"ics/T1692.001","id":"T1692.001","name":"Command Message","domain":"ics","reviewed_on":"2026-09-28","source_url":"https://attack.mitre.org/techniques/T1692/001","source_file":{"file":"ics.json","url":"https://raw.githubusercontent.com/mitre-attack/attack-stix-data/20664a889568dce884a1dac0ec7b12ae3a199f51/ics-attack/ics-attack-20.0.json","sha256":"c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183","bytes":5266683},"source_object_sha256":"4a673cc206d2222d71540968ec154be28079eb9561c7e3a48d3cb6e7d86eedd3","description":"Adversaries may send unauthorized command messages to instruct control system assets to perform actions outside of their intended functionality, or without the logical preconditions to trigger their expected function. Command messages are used in ICS networks to give direct instructions to control systems devices. If an adversary can send an unauthorized command message to a control system, then it can instruct the control systems device to perform an action outside the normal bounds of the device's actions. An adversary could potentially instruct a control systems device to perform an action that will cause an [Impact](https://attack.mitre.org/tactics/TA0105).(Citation: Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011). An adversary could also misuse control system devices to store data collected from the network for later use.\n\nIn the Dallas Siren incident, adversaries were able to send command messages to activate tornado alarm systems across the city without an impending tornado or other disaster.(Citation: Zack Whittaker April 2017)(Citation: Benjamin Freed March 2019)","references":[{"source_name":"mitre-attack","url":"https://attack.mitre.org/techniques/T1692/001","external_id":"T1692.001"},{"source_name":"Benjamin Freed March 2019","description":"Benjamin Freed 2019, March 13 Tornado sirens in Dallas suburbs deactivated after being hacked and set off Retrieved. 2020/11/06 ","url":"https://statescoop.com/tornado-sirens-in-dallas-suburbs-deactivated-after-being-hacked-and-set-off/"},{"source_name":"Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011","description":"Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011 A Taxonomy of Cyber Attacks on SCADA Systems Retrieved. 2018/01/12 ","url":"http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6142258"},{"source_name":"Zack Whittaker April 2017","description":"Zack Whittaker 2017, April 12 Dallas' emergency sirens were hacked with a rogue radio signal Retrieved. 2020/11/06 ","url":"https://www.zdnet.com/article/experts-think-they-know-how-dallas-emergency-sirens-were-hacked/"}],"platforms":["Embedded","Windows","Linux"],"environments":["cloud-hosted-endpoint","ics-ot","onprem"],"visibility":"source_mapped","visibility_note":null,"parent":{"key":"ics/T1692","id":"T1692","name":"Unauthorized Message","domain":"ics","level":"technique","parent_id":null,"tactics":["evasion","impair-process-control"],"platforms":["Embedded","Windows","Linux"],"environments":["cloud-hosted-endpoint","ics-ot","onprem"],"page":"techniques/ics/T1692/","constraints":["isolated_authorized_lab","procedure_review_required","telemetry_configuration_required","ot_fixture_and_process_safety_review","potential_disruption_requires_individual_review"],"telemetry_tags":["Network Connection Creation","Network Traffic Content","Network Traffic Flow"],"telemetry_references":[{"id":"DC0082","name":"Network Connection Creation","tag":"Network Connection Creation","page":"telemetry/DC0082/","kind":"attack_component"},{"id":"DC0085","name":"Network Traffic Content","tag":"Network Traffic Content","page":"telemetry/DC0085/","kind":"attack_component"},{"id":"DC0078","name":"Network Traffic Flow","tag":"Network Traffic Flow","page":"telemetry/DC0078/","kind":"attack_component"}],"detections":{"page":"detections/ics/T1692/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":3,"live_validated":0},"anomaly_types":[]},"detection_status":"guidance_only","anomaly_tags":[],"tool_tags":[],"tool_references":[],"visibility":"source_mapped","telemetry_status":"mapped","classification":"cannot_simulate_yet","candidate_count":0,"implementation":"not_integrated","methods":[]},"children":[],"telemetry":[{"id":"DC0038","name":"Application Log Content","page":"telemetry/DC0038/","kind":"attack_component","category":"Application and service audit","description":"Application-emitted audit or operational event content.","collection_focus":"Select the application event family required by the detection and document its native schema before normalization.","providers":[{"name":"Application audit logs","scope":"First-party service events and request/result fields; schema is application-specific.","source_id":"otel"},{"name":"OpenTelemetry-compatible log pipelines","scope":"Transport and normalization of emitted records; do not create missing audit instrumentation.","source_id":"otel"}],"configuration":["Enable the application audit category or instrument the owned lab application at the authorization/action boundary.","Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.","Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart."],"configuration_example":null,"required_fields":["service","action","actor","record_count","result"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0038","collector":"illustrative-lab-collector","observation":{"service":"lab-portal","action":"export_requested","actor":"lab-reader","record_count":3,"result":"authorized"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.","sources":[{"id":"otel","title":"OpenTelemetry log data model","url":"https://opentelemetry.io/docs/specs/otel/logs/data-model/"}],"association":"attack_component","anomaly_design":"Per application, client and route: request rate, rare actions, failure ratios and unusual state transitions. Version changes, retries, health probes and seasonal load need separate baselines."},{"id":"DC0085","name":"Network Traffic Content","page":"telemetry/DC0085/","kind":"attack_component","category":"Network and protocol telemetry","description":"Packet or decoded application-protocol content visible at a network sensor.","collection_focus":"Scope approved packet capture/protocol content collection to the lab flow; retain capture provenance and truncation indicators.","providers":[{"name":"Zeek","scope":"Connection and protocol metadata from traffic visible to the sensor.","source_id":"zeek"},{"name":"Suricata EVE","scope":"Configured flow, alert, DNS, HTTP, TLS and protocol records.","source_id":"suricata"}],"configuration":["Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.","Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.","Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection."],"configuration_example":null,"required_fields":["flow_id","protocol","method","path","payload_excerpt"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0085","collector":"illustrative-lab-collector","observation":{"flow_id":"lab-flow-1","protocol":"http","method":"GET","path":"/lab-check","payload_excerpt":"LAB_TELEMETRY_CHECK"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.","sources":[{"id":"zeek","title":"Zeek protocol and connection logs","url":"https://docs.zeek.org/en/current/reference/logs/index.html"},{"id":"zeek_start","title":"Zeek capture setup","url":"https://docs.zeek.org/en/current/quickstart.html"},{"id":"suricata","title":"Suricata EVE JSON output","url":"https://docs.suricata.io/en/latest/output/eve/eve-json-output.html"}],"association":"attack_component","anomaly_design":"Per source and observation point: connection rate, destination-host/port fan-out, response/failure ratio and previously unseen destinations. Compare equivalent time windows; separate authorized scanners, NAT and sampling effects."},{"id":"DC0107","name":"Process History/Live Data","page":"telemetry/DC0107/","kind":"attack_component","category":"Industrial operations and physical process","description":"Time-series measurements of an industrial process, including historical and live values.","collection_focus":"Export historian/process tags with engineering units, quality and source timestamps; define expected sample rate and compare an independent signal.","providers":[{"name":"OPC UA audit-capable servers","scope":"Auditable actions where supported and enabled; inspect server conformance and vendor documentation.","source_id":"opc"},{"name":"Controller, HMI and historian exports","scope":"Vendor-specific process values, quality flags, alarms and operational context.","source_id":"ot"},{"name":"Independent lab sensors / safety records","scope":"Physical-effect corroboration, not a universal cybersecurity log format.","source_id":"ot"}],"configuration":["Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.","Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.","Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs."],"configuration_example":null,"required_fields":["tag","value","unit","quality"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0107","collector":"illustrative-lab-collector","observation":{"tag":"LAB.TankLevel","value":42,"unit":"percent","quality":"good"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.","sources":[{"id":"opc","title":"OPC UA audit event model","url":"https://reference.opcfoundation.org/specs/OPC-10000-3/9.5"},{"id":"ot","title":"NIST SP 800-82 Rev. 3: OT security","url":"https://csrc.nist.gov/pubs/sp/800/82/r3/final"}],"association":"attack_component","anomaly_design":"Per asset, operating mode and engineering change window: deviations in command/state sequences, measurement residuals and communication freshness. Use a simulator or approved test rig; never generate hazardous physical effects."},{"id":"DC0109","name":"Process/Event Alarm","page":"telemetry/DC0109/","kind":"attack_component","category":"Industrial operations and physical process","description":"Alarms raised by process conditions or operational events.","collection_focus":"Export alarm/event history with setpoint context and lifecycle transitions; retain suppressed/shelved state when provided.","providers":[{"name":"OPC UA audit-capable servers","scope":"Auditable actions where supported and enabled; inspect server conformance and vendor documentation.","source_id":"opc"},{"name":"Controller, HMI and historian exports","scope":"Vendor-specific process values, quality flags, alarms and operational context.","source_id":"ot"},{"name":"Independent lab sensors / safety records","scope":"Physical-effect corroboration, not a universal cybersecurity log format.","source_id":"ot"}],"configuration":["Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.","Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.","Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs."],"configuration_example":null,"required_fields":["tag","alarm","threshold","value","acknowledged"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0109","collector":"illustrative-lab-collector","observation":{"tag":"LAB.TankLevel","alarm":"high_level","threshold":80,"value":82,"acknowledged":false}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.","sources":[{"id":"opc","title":"OPC UA audit event model","url":"https://reference.opcfoundation.org/specs/OPC-10000-3/9.5"},{"id":"ot","title":"NIST SP 800-82 Rev. 3: OT security","url":"https://csrc.nist.gov/pubs/sp/800/82/r3/final"}],"association":"attack_component","anomaly_design":"Per asset, operating mode and engineering change window: deviations in command/state sequences, measurement residuals and communication freshness. Use a simulator or approved test rig; never generate hazardous physical effects."}],"detection":{"key":"ics/T1692.001","id":"T1692.001","name":"Command Message","domain":"ics","platforms":["Embedded","Windows","Linux"],"environments":["cloud-hosted-endpoint","ics-ot","onprem"],"source_url":"https://attack.mitre.org/techniques/T1692/001","technique_page":"techniques/ics/T1692.001/","page":"detections/ics/T1692.001/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":3,"live_validated":0},"sigma_rules":[],"atlas_basic":[],"atlas_anomaly":[],"anomaly_types":[],"strategies":[{"id":"DET0794","name":"Detection of Unauthorized Command Message","url":"https://attack.mitre.org/detectionstrategies/DET0794","stix_id":"x-mitre-detection-strategy--d8cb1dd3-8bf2-48e7-99db-473481b823a8","relationship_id":"relationship--c71fafe8-ed54-44d1-be6e-9a018eb9a90f","description":"","analytics":[{"id":"AN1926","name":"Analytic 1926","guidance":"Real-time monitoring identifies a Windows process generating Industrial Control System (ICS) command messages to field device tags representing physical outputs, from a process that is not the recognized Supervisory Control and Data Acquisition (SCADA) or Distributed Control System (DCS) control application, targeting safety-critical output tags. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0794#AN1926","platforms":["Windows"],"tuning":[{"field":"ApprovedSCADAServers","description":"IP allowlist of legitimate control sources."},{"field":"RapidToggleWindow","description":"Time window within which multiple safety-critical output changes are considered a coordinated event."},{"field":"SafetyCriticalOutputAddresses","description":"Documented register/IOA addresses corresponding to safety-critical outputs per device."}],"log_sources":[{"component_id":"DC0038","component":"Application Log Content","name":"opc:applog","channel":"command call to field device output tag from process not matching recognized Supervisory Control and Data Acquisition (SCADA)/Distributed Control System (DCS) control application","platforms":["Windows"],"analytic_id":"AN1926","source_url":"https://attack.mitre.org/detectionstrategies/DET0794#AN1926","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0038/"}]},{"id":"AN2153","name":"Analytic 2153","guidance":"Real-time monitoring identifies a Linux process making Open Platform Communications (OPC) Unified Architecture (UA) write calls or direct Industrial Control System (ICS) protocol command connections to field device output addresses, from a User Identifier (UID) not associated with the authorized control application. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0794#AN2153","platforms":["Linux"],"tuning":[{"field":"ApprovedSCADAServers","description":"IP allowlist of legitimate control sources."},{"field":"RapidToggleWindow","description":"Time window within which multiple safety-critical output changes are considered a coordinated event."},{"field":"SafetyCriticalOutputAddresses","description":"Documented register/IOA addresses corresponding to safety-critical outputs per device."}],"log_sources":[{"component_id":"DC0085","component":"Network Traffic Content","name":"NSM:Content","channel":"decoded ICS protocol write/setpoint operation to a control/output address from a client identity or source not in the approved control-application baseline","platforms":["Linux"],"analytic_id":"AN2153","source_url":"https://attack.mitre.org/detectionstrategies/DET0794#AN2153","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0085/"}]},{"id":"AN2212","name":"Analytic 2212","guidance":"Real-time monitoring identifies a control/command message arriving at a field device from a source not in the approved control server list, where the command targets safety-critical output points and does not correspond to any scheduled or operator-acknowledged process action. Documented precedent: Industroyer2 connected directly to specific International Electrotechnical Commission (IEC)-104 RTUs and toggled hardcoded Information Object Addresses (IOAs) to OFF using command type 46, targeting circuit breaker outputs. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0794#AN2212","platforms":["Embedded"],"tuning":[{"field":"ApprovedSCADAServers","description":"IP allowlist of legitimate control sources."},{"field":"RapidToggleWindow","description":"Time window within which multiple safety-critical output changes are considered a coordinated event."},{"field":"SafetyCriticalOutputAddresses","description":"Documented register/IOA addresses corresponding to safety-critical outputs per device."}],"log_sources":[{"component_id":"DC0109","component":"Process/Event Alarm","name":"operationaldb:AlarmEvent","channel":"process state change recorded without preceding operator_ack or scheduled switching order reference","platforms":["Embedded"],"analytic_id":"AN2212","source_url":"https://attack.mitre.org/detectionstrategies/DET0794#AN2212","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0109/"},{"component_id":"DC0107","component":"Process History/Live Data","name":"operationaldb:ProcessHistory","channel":"multiple safety-critical outputs toggle within rapid toggle window, pattern consistent with scripted issuance","platforms":["Embedded"],"analytic_id":"AN2212","source_url":"https://attack.mitre.org/detectionstrategies/DET0794#AN2212","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0107/"},{"component_id":"DC0085","component":"Network Traffic Content","name":"NSM:Content","channel":"write/operate command targeting safety-critical output addresses from source not in approved Supervisory Control and Data Acquisition (SCADA) servers","platforms":["Embedded"],"analytic_id":"AN2212","source_url":"https://attack.mitre.org/detectionstrategies/DET0794#AN2212","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0085/"}]}]}],"telemetry_references":[{"id":"DC0038","name":"Application Log Content","tag":"Application Log Content","page":"telemetry/DC0038/","kind":"attack_component"},{"id":"DC0085","name":"Network Traffic Content","tag":"Network Traffic Content","page":"telemetry/DC0085/","kind":"attack_component"},{"id":"DC0107","name":"Process History/Live Data","tag":"Process History/Live Data","page":"telemetry/DC0107/","kind":"attack_component"},{"id":"DC0109","name":"Process/Event Alarm","tag":"Process/Event Alarm","page":"telemetry/DC0109/","kind":"attack_component"}],"visibility":"source_mapped","visibility_note":null,"tool_references":[],"related_parent":null,"article_url":"https://1200km.com/articles/read/2026/2026-04-20-malicious-activity-as-a-statistical-signal-a-detection-engineering-analysis-of-anomaly-bas-90df8b6dea12/","validation":{"source_join":"exact_ids","sigma_yaml":"parsed","backend_compilation":"not_run","live_telemetry":"not_run","detection_execution":"not_run"}},"tools":[],"software":[{"id":"S0604","name":"Industroyer","url":"https://attack.mitre.org/software/S0604","kind":"malware","description":"Using its protocol payloads, [Industroyer](https://attack.mitre.org/software/S0604) sends unauthorized commands to RTUs to change the state of equipment. (Citation: Anton Cherepanov, ESET June 2017)","relationship_id":"relationship--bc51e6c7-6211-4124-874d-4a5aea2efce0","references":[{"source_name":"Anton Cherepanov, ESET June 2017","description":"Anton Cherepanov, ESET 2017, June 12 Win32/Industroyer: A new threat for industrial control systems Retrieved. 2017/09/15 ","url":"https://www.welivesecurity.com/wp-content/uploads/2017/06/Win32_Industroyer.pdf"}]},{"id":"S1045","name":"INCONTROLLER","url":"https://attack.mitre.org/software/S1045","kind":"malware","description":"[INCONTROLLER](https://attack.mitre.org/software/S1045) can send custom Modbus commands to write register values on Schneider PLCs.(Citation: CISA-AA22-103A) \n\n[INCONTROLLER](https://attack.mitre.org/software/S1045) can send write tag values on OPC UA servers.(Citation: CISA-AA22-103A) ","relationship_id":"relationship--2f15fa70-7e2d-4ef3-9654-0404e71ac343","references":[{"source_name":"CISA-AA22-103A","description":"DHS/CISA. (2022, May 25). Alert (AA22-103A) APT Cyber Tools Targeting ICS/SCADA Devices. Retrieved September 28, 2022.","url":"https://www.cisa.gov/uscert/ncas/alerts/aa22-103a"}]},{"id":"S1072","name":"Industroyer2","url":"https://attack.mitre.org/software/S1072","kind":"malware","description":"[Industroyer2](https://attack.mitre.org/software/S1072) is capable of sending command messages from the compromised device to target remote stations to open data channels, retrieve the location and values of Information Object Addresses (IOAs), and modify the IO state values through Select Before Operate I/O, Select/Execute, and Invert Default State operations.(Citation: Industroyer2 Mandiant April 2022)(Citation: Industroyer2 Forescout July 2022)","relationship_id":"relationship--898a9eb9-671e-4096-8288-72ffb49e93f3","references":[{"source_name":"Industroyer2 Mandiant April 2022","description":"Daniel Kapellmann Zafra, Raymond Leong, Chris Sistrunk, Ken Proska, Corey Hildebrandt, Keith Lunden, Nathan Brubaker. (2022, April 25). INDUSTROYER.V2: Old Malware Learns New Tricks. Retrieved March 30, 2023.","url":"https://www.mandiant.com/resources/blog/industroyer-v2-old-malware-new-tricks"},{"source_name":"Industroyer2 Forescout July 2022","description":"Forescout. (2022, July 14). Industroyer2 and  INCONTROLLER In-depth Technical Analysis of the Most Recent ICS-specific Malware. Retrieved March 30, 2023.","url":"https://www.forescout.com/resources/industroyer2-and-incontroller-report/"}]}],"actors":[{"id":"G1027","name":"CyberAv3ngers","url":"https://attack.mitre.org/groups/G1027","kind":"intrusion-set","description":"During the [2026 Iranian Water Campaign](https://attack.mitre.org/campaigns/C0065), [CyberAv3ngers](https://attack.mitre.org/groups/G1027) used the manufacturers’ commercial PLC programming and maintenance software to send unauthorized command messages to multiple victim controllers. These include Rockwell Automation’s [Studio Logix 5000 Designer](https://attack.mitre.org/software/S9054), Schneider Electric’s [EcoStruxure Control Expert](https://attack.mitre.org/software/S9056), and Siemens’ [Totally Integrated Automation (TIA) Portal](https://attack.mitre.org/software/S9055) .(Citation: CISA-AA26-097A)","relationship_id":"relationship--abce8e63-b622-441b-9b79-1fdd95da8cff","references":[{"source_name":"CISA-AA26-097A","description":"Cybersecurity and Infrastructure Security Agency. (2026, July 22). Iranian-Affiliated Cyber Actors Exploit Programmable Logic Controllers Across US Critical Infrastructure. Retrieved September 26, 2026.","url":"https://www.cisa.gov/news-events/cybersecurity-advisories/aa26-097a"}]}],"mitigations":[{"id":"M0802","name":"Communication Authenticity","url":"https://attack.mitre.org/mitigations/M0802","kind":"course-of-action","description":"Protocols used for control functions should provide authenticity through MAC functions or digital signatures. If not, utilize bump-in-the-wire devices or VPNs to enforce communication authenticity between devices that are not capable of supporting this (e.g., legacy controllers, RTUs).\n","relationship_id":"relationship--0c68501b-8e36-4d75-9e61-7a518a9ca1f2","references":[]},{"id":"M0807","name":"Network Allowlists","url":"https://attack.mitre.org/mitigations/M0807","kind":"course-of-action","description":"Use host-based allowlists to prevent devices from accepting connections from unauthorized systems. For example, allowlists can be used to ensure devices can only connect with master stations or known management/engineering workstations.(Citation: Department of Homeland Security September 2016)\n","relationship_id":"relationship--bc0e4ff7-ed61-41c0-84ca-66210241c9ce","references":[{"source_name":"Department of Homeland Security September 2016","description":"Department of Homeland Security 2016, September Retrieved. 2020/09/25 ","url":"https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"}]},{"id":"M0813","name":"Software Process and Device Authentication","url":"https://attack.mitre.org/mitigations/M0813","kind":"course-of-action","description":"Devices should authenticate all messages between master and outstation assets.\n","relationship_id":"relationship--3003564d-fb12-4509-946b-818e4e5b8431","references":[]},{"id":"M0818","name":"Validate Program Inputs","url":"https://attack.mitre.org/mitigations/M0818","kind":"course-of-action","description":"Devices and programs that receive command messages from remote systems (e.g., control servers) should verify those commands before taking any actions on them.","relationship_id":"relationship--2de38f5e-b97c-498a-a4c9-f13e5d2d233c","references":[]},{"id":"M0930","name":"Network Segmentation","url":"https://attack.mitre.org/mitigations/M0930","kind":"course-of-action","description":"Segment operational assets and their management devices based on their functional role within the process. Enabling more strict isolation to more critical control and operational information within the control environment.(Citation: Karen Scarfone; Paul Hoffman September 2009)(Citation: Keith Stouffer May 2015)(Citation: Department of Homeland Security September 2016)(Citation: Dwight Anderson 2014) \n","relationship_id":"relationship--fd52f382-115f-483a-82c1-bb31fe5d5eb6","references":[{"source_name":"Department of Homeland Security September 2016","description":"Department of Homeland Security 2016, September Retrieved. 2020/09/25 ","url":"https://us-cert.cisa.gov/sites/default/files/recommended_practices/NCCIC_ICS-CERT_Defense_in_Depth_2016_S508C.pdf"},{"source_name":"Dwight Anderson 2014","description":"Dwight Anderson 2014 Protect Critical Infrastructure Systems With Whitelisting Retrieved. 2020/09/25 ","url":"https://www.sans.org/reading-room/whitepapers/ICS/protect-critical-infrastructure-systems-whitelisting-35312"},{"source_name":"Karen Scarfone; Paul Hoffman September 2009","description":"Karen Scarfone; Paul Hoffman 2009, September Guidelines on Firewalls and Firewall Policy Retrieved. 2020/09/25 ","url":"https://nvlpubs.nist.gov/nistpubs/Legacy/SP/nistspecialpublication800-41r1.pdf"},{"source_name":"Keith Stouffer May 2015","description":"Keith Stouffer 2015, May Guide to Industrial Control Systems (ICS) Security Retrieved. 2018/03/28 ","url":"https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-82r2.pdf"}]},{"id":"M0937","name":"Filter Network Traffic","url":"https://attack.mitre.org/mitigations/M0937","kind":"course-of-action","description":"Perform inline allowlisting of automation protocol commands  to prevent devices from sending unauthorized command or reporting messages. Allow/denylist techniques need to be designed with sufficient accuracy to prevent the unintended blocking of valid messages.\n","relationship_id":"relationship--2f8c9deb-aefe-4fa3-b00c-ec15fd154233","references":[]}],"candidates":[],"simulation":{"atomic_status":"no_atomic_candidate","lab_execution":"not_run","browser_attack_runner":false,"prerequisites":"Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.","scenario":null},"validation":{"source_identity":"checked_against_pinned_source","relationship_join":"exact_ids_no_inheritance","page_contract":"automated_checks_required","sensor_capture":"not_run","detection_backend":"not_run","adversary_simulation":"not_run","independent_incident_fact_check":"not_performed"},"technique_links":{"T1692.001":"/ttp-simulation/techniques/ics/T1692.001/"},"synthetic":{"schema":"1200km.ttp.collection-fixture.v1","synthetic":true,"technique_key":"ics/T1692.001","purpose":"Collection/parser contract exercise, NOT a positive example or detection of this TTP.","events":[{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0038","collector":"illustrative-lab-collector","observation":{"service":"lab-portal","action":"export_requested","actor":"lab-reader","record_count":3,"result":"authorized"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0085","collector":"illustrative-lab-collector","observation":{"flow_id":"lab-flow-1","protocol":"http","method":"GET","path":"/lab-check","payload_excerpt":"LAB_TELEMETRY_CHECK"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0107","collector":"illustrative-lab-collector","observation":{"tag":"LAB.TankLevel","value":42,"unit":"percent","quality":"good"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0109","collector":"illustrative-lab-collector","observation":{"tag":"LAB.TankLevel","alarm":"high_level","threshold":80,"value":82,"acknowledged":false}}]}}