{"source_checked_on":"2026-10-19","schema_version":1,"key":"ics/T1691.001","id":"T1691.001","name":"Command Message","domain":"ics","reviewed_on":"2026-09-28","source_url":"https://attack.mitre.org/techniques/T1691/001","source_file":{"file":"ics.json","url":"https://raw.githubusercontent.com/mitre-attack/attack-stix-data/20664a889568dce884a1dac0ec7b12ae3a199f51/ics-attack/ics-attack-20.0.json","sha256":"c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183","bytes":5266683},"source_object_sha256":"32af9a06b65e8e7fa3566037a54ac352f4a5d9bd0d7b599e3d358ff6a9555ff8","description":"Adversaries may block a command message from reaching its intended target to prevent command execution. In OT networks, command messages are sent to provide instructions to control system devices. A blocked command message can inhibit response functions from correcting a disruption or unsafe condition.(Citation: Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011)(Citation: Electricity Information Sharing and Analysis Center; SANS Industrial Control Systems March 2016)","references":[{"source_name":"mitre-attack","url":"https://attack.mitre.org/techniques/T1691/001","external_id":"T1691.001"},{"source_name":"Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011","description":"Bonnie Zhu, Anthony Joseph, Shankar Sastry 2011 A Taxonomy of Cyber Attacks on SCADA Systems Retrieved. 2018/01/12 ","url":"http://ieeexplore.ieee.org/stamp/stamp.jsp?tp=&arnumber=6142258"},{"source_name":"Electricity Information Sharing and Analysis Center; SANS Industrial Control Systems March 2016","description":"Electricity Information Sharing and Analysis Center; SANS Industrial Control Systems 2016, March 18 Analysis of the Cyber Attack on the Ukranian Power Grid: Defense Use Case Retrieved. 2018/03/27 ","url":"https://assets.contentstack.io/v3/assets/blt36c2e63521272fdc/blt6a77276749b76a40/607f235992f0063e5c070fff/E-ISAC_SANS_Ukraine_DUC_5%5b73%5d.pdf"}],"platforms":["Embedded","Windows","Linux"],"environments":["cloud-hosted-endpoint","ics-ot","onprem"],"visibility":"source_mapped","visibility_note":null,"parent":{"key":"ics/T1691","id":"T1691","name":"Block Operational Technology Message","domain":"ics","level":"technique","parent_id":null,"tactics":["inhibit-response-function"],"platforms":["Embedded","Windows","Linux"],"environments":["cloud-hosted-endpoint","ics-ot","onprem"],"page":"techniques/ics/T1691/","constraints":["isolated_authorized_lab","procedure_review_required","telemetry_configuration_required","ot_fixture_and_process_safety_review","potential_disruption_requires_individual_review"],"telemetry_tags":["Network Traffic Flow","Process Creation","Process/Event Alarm"],"telemetry_references":[{"id":"DC0078","name":"Network Traffic Flow","tag":"Network Traffic Flow","page":"telemetry/DC0078/","kind":"attack_component"},{"id":"DC0032","name":"Process Creation","tag":"Process Creation","page":"telemetry/DC0032/","kind":"attack_component"},{"id":"DC0109","name":"Process/Event Alarm","tag":"Process/Event Alarm","page":"telemetry/DC0109/","kind":"attack_component"}],"detections":{"page":"detections/ics/T1691/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":3,"live_validated":0},"anomaly_types":[]},"detection_status":"guidance_only","anomaly_tags":[],"tool_tags":[],"tool_references":[],"visibility":"source_mapped","telemetry_status":"mapped","classification":"cannot_simulate_yet","candidate_count":0,"implementation":"not_integrated","methods":[]},"children":[],"telemetry":[{"id":"DC0038","name":"Application Log Content","page":"telemetry/DC0038/","kind":"attack_component","category":"Application and service audit","description":"Application-emitted audit or operational event content.","collection_focus":"Select the application event family required by the detection and document its native schema before normalization.","providers":[{"name":"Application audit logs","scope":"First-party service events and request/result fields; schema is application-specific.","source_id":"otel"},{"name":"OpenTelemetry-compatible log pipelines","scope":"Transport and normalization of emitted records; do not create missing audit instrumentation.","source_id":"otel"}],"configuration":["Enable the application audit category or instrument the owned lab application at the authorization/action boundary.","Define a schema with timestamp, service, actor, object, action, result and correlation ID. Export structured records through an authenticated collector.","Redact secrets and personal content, separate audit from debug logs, set retention and verify delivery during rotation/restart."],"configuration_example":null,"required_fields":["service","action","actor","record_count","result"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0038","collector":"illustrative-lab-collector","observation":{"service":"lab-portal","action":"export_requested","actor":"lab-reader","record_count":3,"result":"authorized"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Debug output is not necessarily a durable audit trail. Application developers must emit the relevant event; installing a log pipeline does not make an absent event exist.","sources":[{"id":"otel","title":"OpenTelemetry log data model","url":"https://opentelemetry.io/docs/specs/otel/logs/data-model/"}],"association":"attack_component","anomaly_design":"Per application, client and route: request rate, rare actions, failure ratios and unusual state transitions. Version changes, retries, health probes and seasonal load need separate baselines."},{"id":"DC0082","name":"Network Connection Creation","page":"telemetry/DC0082/","kind":"attack_component","category":"Endpoint activity","description":"Creation of an endpoint network connection linked to a process.","collection_focus":"Enable scoped Sysmon NetworkConnect (3), disabled by default, or a platform-equivalent process-aware network sensor.","providers":[{"name":"Microsoft Sysmon","scope":"Windows event-based collection; enable the event types needed below.","source_id":"sysmon"},{"name":"Linux Audit","scope":"Linux alternative for supported system-call and file events; different semantics and fields.","source_id":"linux"},{"name":"Apple Endpoint Security clients","scope":"macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.","source_id":"apple"}],"configuration":["On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.","Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.","For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms."],"configuration_example":null,"required_fields":["process_guid","destination_ip","destination_port","protocol","initiated"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0082","collector":"illustrative-lab-collector","observation":{"process_guid":"lab-process-001","destination_ip":"198.51.100.20","destination_port":443,"protocol":"tcp","initiated":true}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.","sources":[{"id":"sysmon","title":"Microsoft Sysmon events and configuration","url":"https://learn.microsoft.com/en-us/sysinternals/downloads/sysmon"},{"id":"sysmon_config","title":"Microsoft Sysmon configuration files","url":"https://learn.microsoft.com/en-us/windows/security/operating-system-security/sysmon/sysmon-configuration-files"},{"id":"linux","title":"Linux Audit rule configuration","url":"https://www.man7.org/linux/man-pages/man8/auditctl.8.html"},{"id":"apple","title":"Apple Endpoint Security framework for macOS","url":"https://developer.apple.com/documentation/endpointsecurity"},{"id":"process_audit","title":"Microsoft process creation event 4688","url":"https://learn.microsoft.com/en-us/previous-versions/windows/it-pro/windows-10/security/threat-protection/auditing/event-4688"}],"association":"attack_component","anomaly_design":"Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity."},{"id":"DC0078","name":"Network Traffic Flow","page":"telemetry/DC0078/","kind":"attack_component","category":"Network and protocol telemetry","description":"Connection/flow summaries such as endpoints, duration, byte counts and transport.","collection_focus":"Collect Zeek conn.log, Suricata flow events or exporter equivalents, including observation point and sampling settings.","providers":[{"name":"Zeek","scope":"Connection and protocol metadata from traffic visible to the sensor.","source_id":"zeek"},{"name":"Suricata EVE","scope":"Configured flow, alert, DNS, HTTP, TLS and protocol records.","source_id":"suricata"},{"name":"AWS VPC Flow Logs","scope":"IP traffic metadata alternative; no packet payload or DNS answer history, and some traffic is not logged.","source_id":"flow"}],"configuration":["Use an authorized lab TAP/SPAN, virtual mirror or gateway interface. Define which traffic crosses it; avoid assuming visibility into every segment.","Enable the required Zeek analyzers or Suricata EVE event types. Export logs with sensor identity, clock synchronization and flow correlation identifiers.","Monitor capture loss, truncation and exporter sampling. Capture payload only with approval and restrictive retention; encryption normally prevents plaintext inspection."],"configuration_example":null,"required_fields":["source_ip","destination_ip","destination_port","protocol","bytes_sent","bytes_received"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0078","collector":"illustrative-lab-collector","observation":{"source_ip":"192.0.2.10","destination_ip":"198.51.100.20","destination_port":443,"protocol":"tcp","bytes_sent":128,"bytes_received":512}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Flows are not packet payloads. NAT, asymmetric routes, encryption, missing mirrors and sampling can hide attribution or content. A destination connection alone does not prove malicious intent.","sources":[{"id":"zeek","title":"Zeek protocol and connection logs","url":"https://docs.zeek.org/en/current/reference/logs/index.html"},{"id":"zeek_start","title":"Zeek capture setup","url":"https://docs.zeek.org/en/current/quickstart.html"},{"id":"suricata","title":"Suricata EVE JSON output","url":"https://docs.suricata.io/en/latest/output/eve/eve-json-output.html"},{"id":"flow","title":"AWS VPC Flow Logs","url":"https://docs.aws.amazon.com/vpc/latest/userguide/flow-logs.html"}],"association":"attack_component","anomaly_design":"Per source and observation point: connection rate, destination-host/port fan-out, response/failure ratio and previously unseen destinations. Compare equivalent time windows; separate authorized scanners, NAT and sampling effects."},{"id":"DC0032","name":"Process Creation","page":"telemetry/DC0032/","kind":"attack_component","category":"Endpoint activity","description":"Creation of a process with executable, command line, parent and security context.","collection_focus":"Collect Sysmon ProcessCreate (1); preserve ProcessGuid and parent identifiers. Security 4688 is an alternative with separate audit/command-line settings.","providers":[{"name":"Microsoft Sysmon","scope":"Windows event-based collection; enable the event types needed below.","source_id":"sysmon"},{"name":"Linux Audit","scope":"Linux alternative for supported system-call and file events; different semantics and fields.","source_id":"linux"},{"name":"Apple Endpoint Security clients","scope":"macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.","source_id":"apple"}],"configuration":["On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.","Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.","For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms."],"configuration_example":{"label":"Sysmon filter fragment · merge into the reviewed lab configuration","language":"xml","source_id":"sysmon_config","content":"<EventFiltering>\n  <ProcessCreate onmatch=\"include\">\n    <Image condition=\"is\">C:\\Windows\\System32\\whoami.exe</Image>\n  </ProcessCreate>\n</EventFiltering>","note":"This fragment only selects the named process. It is not a complete production policy. Inspect the installed schema with sysmon64 -s; preserve existing rules, then apply the reviewed complete configuration with sysmon64 -c <configuration-file>."},"required_fields":["process_guid","image","parent_image","command_line","user"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0032","collector":"illustrative-lab-collector","observation":{"process_guid":"lab-process-001","image":"C:\\Windows\\System32\\whoami.exe","parent_image":"C:\\Windows\\System32\\cmd.exe","command_line":"whoami","user":"LAB\\analyst"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.","sources":[{"id":"sysmon","title":"Microsoft Sysmon events and configuration","url":"https://learn.microsoft.com/en-us/sysinternals/downloads/sysmon"},{"id":"sysmon_config","title":"Microsoft Sysmon configuration files","url":"https://learn.microsoft.com/en-us/windows/security/operating-system-security/sysmon/sysmon-configuration-files"},{"id":"linux","title":"Linux Audit rule configuration","url":"https://www.man7.org/linux/man-pages/man8/auditctl.8.html"},{"id":"apple","title":"Apple Endpoint Security framework for macOS","url":"https://developer.apple.com/documentation/endpointsecurity"},{"id":"process_audit","title":"Microsoft process creation event 4688","url":"https://learn.microsoft.com/en-us/previous-versions/windows/it-pro/windows-10/security/threat-protection/auditing/event-4688"}],"association":"attack_component","anomaly_design":"Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity."},{"id":"DC0107","name":"Process History/Live Data","page":"telemetry/DC0107/","kind":"attack_component","category":"Industrial operations and physical process","description":"Time-series measurements of an industrial process, including historical and live values.","collection_focus":"Export historian/process tags with engineering units, quality and source timestamps; define expected sample rate and compare an independent signal.","providers":[{"name":"OPC UA audit-capable servers","scope":"Auditable actions where supported and enabled; inspect server conformance and vendor documentation.","source_id":"opc"},{"name":"Controller, HMI and historian exports","scope":"Vendor-specific process values, quality flags, alarms and operational context.","source_id":"ot"},{"name":"Independent lab sensors / safety records","scope":"Physical-effect corroboration, not a universal cybersecurity log format.","source_id":"ot"}],"configuration":["Agree the measurement points, read-only interfaces, sampling intervals and safety boundary with the process owner. Use a simulator or non-production fixture.","Subscribe to supported audit/alarm events or approved historian exports. Preserve source timestamp, quality, engineering units, asset/tag identity and clock offset.","Compare independent measurements and record gaps/latency. Do not enable intrusive polling, change controller logic or alter safety setpoints merely to generate logs."],"configuration_example":null,"required_fields":["tag","value","unit","quality"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0107","collector":"illustrative-lab-collector","observation":{"tag":"LAB.TankLevel","value":42,"unit":"percent","quality":"good"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"There is no universal PLC event ID or configuration command. Visibility depends on vendor, protocol and process. An alarm or process deviation demonstrates an effect, not necessarily a cyberattack.","sources":[{"id":"opc","title":"OPC UA audit event model","url":"https://reference.opcfoundation.org/specs/OPC-10000-3/9.5"},{"id":"ot","title":"NIST SP 800-82 Rev. 3: OT security","url":"https://csrc.nist.gov/pubs/sp/800/82/r3/final"}],"association":"attack_component","anomaly_design":"Per asset, operating mode and engineering change window: deviations in command/state sequences, measurement residuals and communication freshness. Use a simulator or approved test rig; never generate hazardous physical effects."}],"detection":{"key":"ics/T1691.001","id":"T1691.001","name":"Command Message","domain":"ics","platforms":["Embedded","Windows","Linux"],"environments":["cloud-hosted-endpoint","ics-ot","onprem"],"source_url":"https://attack.mitre.org/techniques/T1691/001","technique_page":"techniques/ics/T1691.001/","page":"detections/ics/T1691.001/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":3,"live_validated":0},"sigma_rules":[],"atlas_basic":[],"atlas_anomaly":[],"anomaly_types":[],"strategies":[{"id":"DET0784","name":"Detection of Block Command Message","url":"https://attack.mitre.org/detectionstrategies/DET0784","stix_id":"x-mitre-detection-strategy--2a1619a7-dd27-48e4-b56f-806cb3d2e405","relationship_id":"relationship--11b201bc-675b-46ac-89a6-80f90deecc12","description":"","analytics":[{"id":"AN1916","name":"Analytic 1916","guidance":"Real-time monitoring identifies the absence of expected command-message delivery confirmation -- a Supervisory Control and Data Acquisition (SCADA)-issued command that does not produce the expected corresponding state-change response within the normal response latency window, while the device remains reachable for other traffic. Documented in the 2015 Ukraine attack, where Sandworm used malicious firmware to render serial-to-Ethernet converters inoperable. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0784#AN1916","platforms":["Embedded"],"tuning":[{"field":"CommandConfirmationWindow","description":"Maximum expected latency between a command being issued and its corresponding state-change confirmation."}],"log_sources":[{"component_id":"DC0107","component":"Process History/Live Data","name":"operationaldb:ProcessHistory","channel":"process value expected to change following a command does not change within command confirmation window","platforms":["Embedded"],"analytic_id":"AN1916","source_url":"https://attack.mitre.org/detectionstrategies/DET0784#AN1916","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0107/"},{"component_id":"DC0078","component":"Network Traffic Flow","name":"NSM:Connections","channel":"command-type traffic to device_ip absent while other traffic types (polling, reporting) to the same device continue normally","platforms":["Embedded"],"analytic_id":"AN1916","source_url":"https://attack.mitre.org/detectionstrategies/DET0784#AN1916","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0078/"},{"component_id":"DC0038","component":"Application Log Content","name":"scada:applog","channel":"command issued to device_ip with no corresponding state-change confirmation received within command confirmation window","platforms":["Embedded"],"analytic_id":"AN1916","source_url":"https://attack.mitre.org/detectionstrategies/DET0784#AN1916","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0038/"}]},{"id":"AN2118","name":"Analytic 2118","guidance":"Real-time monitoring identifies iptables/nftables rule additions on Industrial Control System (ICS) Linux gateways that filter ICS command messages based on content, while allowing other traffic to pass. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0784#AN2118","platforms":["Linux"],"tuning":[{"field":"CommandConfirmationWindow","description":"Maximum expected latency between a command being issued and its corresponding state-change confirmation."}],"log_sources":[{"component_id":"DC0032","component":"Process Creation","name":"auditd:SYSCALL","channel":"Linux Audit SYSCALL/EXECVE/SOCKADDR records (configured audit rule): syscall=execve; command line invokes iptables/nftables to change ICS traffic filtering or redirection outside the authorized network-administration baseline","platforms":["Linux"],"analytic_id":"AN2118","source_url":"https://attack.mitre.org/detectionstrategies/DET0784#AN2118","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0032/"}]},{"id":"AN2263","name":"Analytic 2263","guidance":"Real-time monitoring identifies Windows host-based firewall rule modifications or network interface configuration changes on Industrial Control System (ICS) Windows servers that block ICS command-message traffic, coinciding with Supervisory Control and Data Acquisition (SCADA) showing communication loss to field devices. OT operational-fidelity gate: Alert only when the action is not attributable to an authorized operator/engineering source for the specific target and function, and it is either outside an approved change/maintenance window or lacks matching change-control context; where telemetry permits, require corroborating device, configuration, or process-state effect. Suppress activity that fully matches approved maintenance, commissioning, failover, recovery, or tested control procedures.","url":"https://attack.mitre.org/detectionstrategies/DET0784#AN2263","platforms":["Windows"],"tuning":[{"field":"CommandConfirmationWindow","description":"Maximum expected latency between a command being issued and its corresponding state-change confirmation."}],"log_sources":[{"component_id":"DC0082","component":"Network Connection Creation","name":"WinEventLog:Security","channel":"EventCode=5157 or firewall rule changes blocking Industrial Control Systems (ICS) command message traffic","platforms":["Windows"],"analytic_id":"AN2263","source_url":"https://attack.mitre.org/detectionstrategies/DET0784#AN2263","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0082/"}]}]}],"telemetry_references":[{"id":"DC0038","name":"Application Log Content","tag":"Application Log Content","page":"telemetry/DC0038/","kind":"attack_component"},{"id":"DC0082","name":"Network Connection Creation","tag":"Network Connection Creation","page":"telemetry/DC0082/","kind":"attack_component"},{"id":"DC0078","name":"Network Traffic Flow","tag":"Network Traffic Flow","page":"telemetry/DC0078/","kind":"attack_component"},{"id":"DC0032","name":"Process Creation","tag":"Process Creation","page":"telemetry/DC0032/","kind":"attack_component"},{"id":"DC0107","name":"Process History/Live Data","tag":"Process History/Live Data","page":"telemetry/DC0107/","kind":"attack_component"}],"visibility":"source_mapped","visibility_note":null,"tool_references":[],"related_parent":null,"article_url":"https://1200km.com/articles/read/2026/2026-04-20-malicious-activity-as-a-statistical-signal-a-detection-engineering-analysis-of-anomaly-bas-90df8b6dea12/","validation":{"source_join":"exact_ids","sigma_yaml":"parsed","backend_compilation":"not_run","live_telemetry":"not_run","detection_execution":"not_run"}},"tools":[],"software":[{"id":"S0604","name":"Industroyer","url":"https://attack.mitre.org/software/S0604","kind":"malware","description":"In [Industroyer](https://attack.mitre.org/software/S0604) the first COM port from the configuration file is used for the actual communication and the two other COM ports are just opened to prevent other processes accessing them. Thus, the IEC 101 payload component is able to take over and maintain control of the RTU device. (Citation: Anton Cherepanov, ESET June 2017)","relationship_id":"relationship--6ce3bd17-de4c-4ff3-9f7d-ae30efae2b58","references":[{"source_name":"Anton Cherepanov, ESET June 2017","description":"Anton Cherepanov, ESET 2017, June 12 Win32/Industroyer: A new threat for industrial control systems Retrieved. 2017/09/15 ","url":"https://www.welivesecurity.com/wp-content/uploads/2017/06/Win32_Industroyer.pdf"}]}],"actors":[],"mitigations":[{"id":"M0807","name":"Network Allowlists","url":"https://attack.mitre.org/mitigations/M0807","kind":"course-of-action","description":"Utilize network allowlists to restrict unnecessary connections to network devices (e.g., comm servers, serial to ethernet converters) and services, especially in cases when devices have limits on the number of simultaneous sessions they support.\n","relationship_id":"relationship--a6ebd61b-7845-4694-9860-2e8998f2841f","references":[]},{"id":"M0810","name":"Out-of-Band Communications Channel","url":"https://attack.mitre.org/mitigations/M0810","kind":"course-of-action","description":"Provide an alternative method for sending critical command messages to outstations, this could include using radio/cell communication to send messages to a field technician that physically performs the control function.\n","relationship_id":"relationship--2c6c4752-536e-4b96-86d7-7efe88350082","references":[]},{"id":"M0814","name":"Static Network Configuration","url":"https://attack.mitre.org/mitigations/M0814","kind":"course-of-action","description":"Unauthorized connections can be prevented by statically defining the hosts and ports used for automation protocol connections.\n","relationship_id":"relationship--eba478bb-7b76-4889-b82c-eda10826ffcb","references":[]}],"candidates":[],"simulation":{"atomic_status":"no_atomic_candidate","lab_execution":"not_run","browser_attack_runner":false,"prerequisites":"Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.","scenario":null},"validation":{"source_identity":"checked_against_pinned_source","relationship_join":"exact_ids_no_inheritance","page_contract":"automated_checks_required","sensor_capture":"not_run","detection_backend":"not_run","adversary_simulation":"not_run","independent_incident_fact_check":"not_performed"},"technique_links":{"T1691.001":"/ttp-simulation/techniques/ics/T1691.001/"},"synthetic":{"schema":"1200km.ttp.collection-fixture.v1","synthetic":true,"technique_key":"ics/T1691.001","purpose":"Collection/parser contract exercise, NOT a positive example or detection of this TTP.","events":[{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0038","collector":"illustrative-lab-collector","observation":{"service":"lab-portal","action":"export_requested","actor":"lab-reader","record_count":3,"result":"authorized"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0082","collector":"illustrative-lab-collector","observation":{"process_guid":"lab-process-001","destination_ip":"198.51.100.20","destination_port":443,"protocol":"tcp","initiated":true}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0078","collector":"illustrative-lab-collector","observation":{"source_ip":"192.0.2.10","destination_ip":"198.51.100.20","destination_port":443,"protocol":"tcp","bytes_sent":128,"bytes_received":512}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0032","collector":"illustrative-lab-collector","observation":{"process_guid":"lab-process-001","image":"C:\\Windows\\System32\\whoami.exe","parent_image":"C:\\Windows\\System32\\cmd.exe","command_line":"whoami","user":"LAB\\analyst"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0107","collector":"illustrative-lab-collector","observation":{"tag":"LAB.TankLevel","value":42,"unit":"percent","quality":"good"}}]}}