{"source_checked_on":"2026-10-19","schema_version":1,"key":"ics/T0873.001","id":"T0873.001","name":"Siemens Project File Format","domain":"ics","reviewed_on":"2026-09-28","source_url":"https://attack.mitre.org/techniques/T0873/001","source_file":{"file":"ics.json","url":"https://raw.githubusercontent.com/mitre-attack/attack-stix-data/20664a889568dce884a1dac0ec7b12ae3a199f51/ics-attack/ics-attack-20.0.json","sha256":"c9ca0ce523a1b5e512060a390415e8aefe8f6d32c5f82d7de81264960c1e1183","bytes":5266683},"source_object_sha256":"66a5aedf194bdbf2fb4ad1f4fd9e7200e0790f92bd23e605d5839ba930dbfa24","description":"Adversaries may infect Siemens PLC project files (i.e., Step 7, WinCC, etc.) to achieve [Execution](https://attack.mitre.org/tactics/TA0104), [Persistence](https://attack.mitre.org/tactics/TA0110), and [Lateral Movement](https://attack.mitre.org/tactics/TA0109) objectives. Adversaries may modify an existing project file or bring their own project files into the environment.(Citation: Nicolas Falliere, Liam O Murchu, Eric Chien February 2011)\n\nThe ability for an adversary to deploy an infected project file relies on access to a workstation with Siemens PLC programming software installed on it from which a program download can be performed.\n","references":[{"source_name":"mitre-attack","url":"https://attack.mitre.org/techniques/T0873/001","external_id":"T0873.001"},{"source_name":"Nicolas Falliere, Liam O Murchu, Eric Chien February 2011","description":"Nicolas Falliere, Liam O Murchu, Eric Chien 2011, February W32.Stuxnet Dossier (Version 1.4) Retrieved November 17, 2024.","url":"https://docs.broadcom.com/doc/security-response-w32-stuxnet-dossier-11-en"}],"platforms":["Windows","Linux"],"environments":["cloud-hosted-endpoint","ics-ot","onprem"],"visibility":"source_mapped","visibility_note":null,"parent":{"key":"ics/T0873","id":"T0873","name":"Project File Infection","domain":"ics","level":"technique","parent_id":null,"tactics":["persistence"],"platforms":["Windows","Linux"],"environments":["cloud-hosted-endpoint","ics-ot","onprem"],"page":"techniques/ics/T0873/","constraints":["isolated_authorized_lab","procedure_review_required","telemetry_configuration_required","ot_fixture_and_process_safety_review"],"telemetry_tags":["File Access","File Metadata"],"telemetry_references":[{"id":"DC0055","name":"File Access","tag":"File Access","page":"telemetry/DC0055/","kind":"attack_component"},{"id":"DC0059","name":"File Metadata","tag":"File Metadata","page":"telemetry/DC0059/","kind":"attack_component"}],"detections":{"page":"detections/ics/T0873/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":2,"live_validated":0},"anomaly_types":[]},"detection_status":"guidance_only","anomaly_tags":[],"tool_tags":[],"tool_references":[],"visibility":"source_mapped","telemetry_status":"mapped","classification":"cannot_simulate_yet","candidate_count":0,"implementation":"not_integrated","methods":[]},"children":[],"telemetry":[{"id":"DC0055","name":"File Access","page":"telemetry/DC0055/","kind":"attack_component","category":"Windows and directory audit","description":"Access to file objects with user, process and access-right context.","collection_focus":"Enable Audit File System plus a narrow SACL on a lab directory; on Linux select path/syscall rules and join associated Audit records.","providers":[{"name":"Windows Security auditing","scope":"Policy-dependent account, object, task and logon records on the host that performs the operation.","source_id":"audit"}],"configuration":["Use a lab-only GPO under Computer Configuration → Windows Settings → Security Settings → Advanced Audit Policy Configuration. Enable the specific subcategory named below.","For object-level auditing, configure a narrow system access control list (SACL) on the test object in addition to policy. Do not audit an entire production directory by default.","Forward Security events from the responsible host or controller; retain subject and target identities, object identifiers, result and original XML. Confirm effective policy with auditpol /get /category:*."],"configuration_example":null,"required_fields":["path","access","actor","result"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0055","collector":"illustrative-lab-collector","observation":{"path":"C:\\Lab\\demo.txt","access":"read","actor":"LAB\\analyst","result":"success"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"A policy checkbox alone does not guarantee an event. Host role, SACL, success/failure selection and audit policy precedence matter. Directory changes may arrive as multiple records.","sources":[{"id":"audit","title":"Microsoft advanced security audit policy","url":"https://learn.microsoft.com/en-us/previous-versions/windows/it-pro/windows-10/security/threat-protection/auditing/advanced-security-audit-policy-settings"},{"id":"ad","title":"Microsoft Audit Directory Service Changes","url":"https://learn.microsoft.com/windows/security/threat-protection/auditing/audit-directory-service-changes"},{"id":"task","title":"Microsoft scheduled-task creation event 4698","url":"https://learn.microsoft.com/en-us/previous-versions/windows/it-pro/windows-10/security/threat-protection/auditing/event-4698"}],"association":"attack_component","anomaly_design":"Per principal, host and object: unusual access/request rates, new principal-object relationships, and changes outside approved administration windows. Control for service accounts and scheduled directory maintenance."},{"id":"DC0061","name":"File Modification","page":"telemetry/DC0061/","kind":"attack_component","category":"Endpoint activity","description":"Changes to file data or attributes.","collection_focus":"Use file-integrity monitoring or scoped OS file-write auditing for general changes. Sysmon 2 records creation-time changes; it is not a general file-write event.","providers":[{"name":"Microsoft Sysmon","scope":"Windows event-based collection; enable the event types needed below.","source_id":"sysmon"},{"name":"Linux Audit","scope":"Linux alternative for supported system-call and file events; different semantics and fields.","source_id":"linux"},{"name":"Apple Endpoint Security clients","scope":"macOS alternative where the subscribed event exists; requires an entitled, approved client, not an iOS collector.","source_id":"apple"}],"configuration":["On a disposable Windows host, review the installed Sysmon schema and current configuration; merge scoped event filters into the existing policy rather than replacing it.","Forward Microsoft-Windows-Sysmon/Operational to the lab collector. Preserve event ID, timestamp, computer, process identifiers and the original event.","For Linux or macOS, select the equivalent sensor separately and test its emitted fields; a Windows event ID does not transfer across platforms."],"configuration_example":null,"required_fields":["path","attribute","before","after"],"example":{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0061","collector":"illustrative-lab-collector","observation":{"path":"C:\\Lab\\demo.txt","attribute":"content_hash","before":"aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa","after":"bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb"}},"example_note":"Project-normalized synthetic JSON, not a native provider log, captured event, attack verdict or validated detection. A parser/adapter is required for a real SIEM. Example names, IPs and values are fictional.","limitations":"Event filtering and sensor versions change coverage. High-volume image-load and process-access collection needs tuning; endpoint events alone do not establish intent.","sources":[{"id":"sysmon","title":"Microsoft Sysmon events and configuration","url":"https://learn.microsoft.com/en-us/sysinternals/downloads/sysmon"},{"id":"sysmon_config","title":"Microsoft Sysmon configuration files","url":"https://learn.microsoft.com/en-us/windows/security/operating-system-security/sysmon/sysmon-configuration-files"},{"id":"linux","title":"Linux Audit rule configuration","url":"https://www.man7.org/linux/man-pages/man8/auditctl.8.html"},{"id":"apple","title":"Apple Endpoint Security framework for macOS","url":"https://developer.apple.com/documentation/endpointsecurity"},{"id":"process_audit","title":"Microsoft process creation event 4688","url":"https://learn.microsoft.com/en-us/previous-versions/windows/it-pro/windows-10/security/threat-protection/auditing/event-4688"}],"association":"attack_component","anomaly_design":"Per host role and user: rare process/object combinations, bursts of object access or modification, and ordered parent/action sequences. Compare maintenance windows and signed software rollout activity."}],"detection":{"key":"ics/T0873.001","id":"T0873.001","name":"Siemens Project File Format","domain":"ics","platforms":["Windows","Linux"],"environments":["cloud-hosted-endpoint","ics-ot","onprem"],"source_url":"https://attack.mitre.org/techniques/T0873/001","technique_page":"techniques/ics/T0873.001/","page":"detections/ics/T0873.001/","status":"guidance_only","counts":{"sigma":0,"atlas_basic":0,"atlas_anomaly":0,"strategies":1,"analytics":2,"live_validated":0},"sigma_rules":[],"atlas_basic":[],"atlas_anomaly":[],"anomaly_types":[],"strategies":[{"id":"DET0906","name":"Detection of Siemens Project File Format Infection","url":"https://attack.mitre.org/detectionstrategies/DET0906","stix_id":"x-mitre-detection-strategy--31773402-e407-4ed3-b86c-7a8587dc5ec9","relationship_id":"relationship--ca77cbbf-8938-4dd0-b454-df5703bc1718","description":"","analytics":[{"id":"AN2049","name":"Analytic 2049","guidance":"Configured Windows object-access monitoring identifies a write to a Siemens project file by a process that is not the Siemens Totally Integrated Automation (TIA) Portal or Step7 engineering software, or by the legitimate Siemens tool immediately after loading a project from an untrusted path. Directly documented as a Stuxnet mechanism. OT operational-fidelity gate: Alert only when execution violates an approved signer/hash/path/parent/process or tool allowlist, or originates from an unauthorized user/tool, and is tied to an OT asset or follow-on OT-relevant action. Suppress vendor-signed software, approved engineering utilities, diagnostics, patching, backup, and documented maintenance. Collection requirement: use Windows Security Event ID 4663 with Object Access auditing and SACLs on approved project repositories; Sysmon FileCreate events can corroborate writes/overwrites but do not report generic file-open/read activity.","url":"https://attack.mitre.org/detectionstrategies/DET0906#AN2049","platforms":["Windows"],"tuning":[{"field":"ApprovedProjectRepository","description":"Documented, trusted source location(s) for Siemens project files."}],"log_sources":[{"component_id":"DC0055","component":"File Access","name":"WinEventLog:Security","channel":"Windows Security Event ID 4663 (requires Object Access auditing/SACL): Siemens engineering process reads/opens project file from unapproved repository/removable-media/network-share path","platforms":["Windows"],"analytic_id":"AN2049","source_url":"https://attack.mitre.org/detectionstrategies/DET0906#AN2049","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0055/"},{"component_id":"DC0061","component":"File Modification","name":"WinEventLog:Sysmon","channel":"Siemens engineering tool opens project file from path not in approved project repository","platforms":["Windows"],"analytic_id":"AN2049","source_url":"https://attack.mitre.org/detectionstrategies/DET0906#AN2049","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0061/"}]},{"id":"AN2120","name":"Analytic 2120","guidance":"Real-time monitoring identifies a write to a Siemens project file path on a Linux engineering workstation from a User Identifier (UID) not associated with the Siemens engineering tool runtime. OT operational-fidelity gate: Alert only when execution violates an approved signer/hash/path/parent/process or tool allowlist, or originates from an unauthorized user/tool, and is tied to an OT asset or follow-on OT-relevant action. Suppress vendor-signed software, approved engineering utilities, diagnostics, patching, backup, and documented maintenance.","url":"https://attack.mitre.org/detectionstrategies/DET0906#AN2120","platforms":["Linux"],"tuning":[{"field":"ApprovedProjectRepository","description":"Documented, trusted source location(s) for Siemens project files."}],"log_sources":[{"component_id":"DC0061","component":"File Modification","name":"auditd:SYSCALL+PATH","channel":"Linux Audit SYSCALL+PATH records: write to Siemens project file path by User Identifier (UID) not in authorized Siemens engineering UIDs","platforms":["Linux"],"analytic_id":"AN2120","source_url":"https://attack.mitre.org/detectionstrategies/DET0906#AN2120","validation":"upstream_definition_not_locally_validated","component_page":"telemetry/DC0061/"}]}]}],"telemetry_references":[{"id":"DC0055","name":"File Access","tag":"File Access","page":"telemetry/DC0055/","kind":"attack_component"},{"id":"DC0061","name":"File Modification","tag":"File Modification","page":"telemetry/DC0061/","kind":"attack_component"}],"visibility":"source_mapped","visibility_note":null,"tool_references":[],"related_parent":null,"article_url":"https://1200km.com/articles/read/2026/2026-04-20-malicious-activity-as-a-statistical-signal-a-detection-engineering-analysis-of-anomaly-bas-90df8b6dea12/","validation":{"source_join":"exact_ids","sigma_yaml":"parsed","backend_compilation":"not_run","live_telemetry":"not_run","detection_execution":"not_run"}},"tools":[],"software":[{"id":"S0603","name":"Stuxnet","url":"https://attack.mitre.org/software/S0603","kind":"malware","description":"[Stuxnet](https://attack.mitre.org/software/S0603) copies itself into Step 7 projects in such a way that it automatically executes when the Step 7 project is loaded. (Citation: Nicolas Falliere, Liam O Murchu, Eric Chien February 2011)","relationship_id":"relationship--aa444531-fa05-4bb4-a23e-8ac133781131","references":[{"source_name":"Nicolas Falliere, Liam O Murchu, Eric Chien February 2011","description":"Nicolas Falliere, Liam O Murchu, Eric Chien 2011, February W32.Stuxnet Dossier (Version 1.4) Retrieved November 17, 2024.","url":"https://docs.broadcom.com/doc/security-response-w32-stuxnet-dossier-11-en"}]}],"actors":[],"mitigations":[{"id":"M0922","name":"Restrict File and Directory Permissions","url":"https://attack.mitre.org/mitigations/M0922","kind":"course-of-action","description":"Ensure permissions restrict project file access to only engineer and technician user groups and accounts.","relationship_id":"relationship--fc02e858-0e4d-462c-8f66-f7289677c559","references":[]},{"id":"M0941","name":"Encrypt Sensitive Information","url":"https://attack.mitre.org/mitigations/M0941","kind":"course-of-action","description":"When at rest, project files should be encrypted to prevent unauthorized changes.(Citation: National Institute of Standards and Technology April 2013)","relationship_id":"relationship--d67feaac-73ac-47b1-91ec-f537105afc58","references":[{"source_name":"National Institute of Standards and Technology April 2013","description":"National Institute of Standards and Technology 2013, April Security and Privacy Controls for Federal Information Systems and Organizations Retrieved. 2020/09/17 ","url":"https://nvlpubs.nist.gov/nistpubs/SpecialPublications/NIST.SP.800-53r4.pdf"}]},{"id":"M0945","name":"Code Signing","url":"https://attack.mitre.org/mitigations/M0945","kind":"course-of-action","description":"Allow for code signing of any project files stored at rest to prevent unauthorized tampering. Ensure the signing keys are not easily accessible on the same system.","relationship_id":"relationship--0f41614d-c37c-47d1-9616-6dae9b73b532","references":[]},{"id":"M0947","name":"Audit","url":"https://attack.mitre.org/mitigations/M0947","kind":"course-of-action","description":"Review the integrity of project files to verify they have not been modified by adversary behavior. Verify a cryptographic hash for the file with a known trusted version, or look for other indicators of modification (e.g., timestamps).","relationship_id":"relationship--f710e99a-dfe9-4b2b-8b1b-97ab1c9d65f3","references":[]}],"candidates":[],"simulation":{"atomic_status":"no_atomic_candidate","lab_execution":"not_run","browser_attack_runner":false,"prerequisites":"Use a process simulator or isolated test rig with no connection to production controllers or physical actuators. Preserve safety interlocks; destructive effects require synthetic evidence, not real equipment damage.","scenario":null},"validation":{"source_identity":"checked_against_pinned_source","relationship_join":"exact_ids_no_inheritance","page_contract":"automated_checks_required","sensor_capture":"not_run","detection_backend":"not_run","adversary_simulation":"not_run","independent_incident_fact_check":"not_performed"},"technique_links":{"T0873.001":"/ttp-simulation/techniques/ics/T0873.001/"},"synthetic":{"schema":"1200km.ttp.collection-fixture.v1","synthetic":true,"technique_key":"ics/T0873.001","purpose":"Collection/parser contract exercise, NOT a positive example or detection of this TTP.","events":[{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0055","collector":"illustrative-lab-collector","observation":{"path":"C:\\Lab\\demo.txt","access":"read","actor":"LAB\\analyst","result":"success"}},{"schema":"1200km.telemetry.example.v1","synthetic":true,"timestamp":"2026-09-27T12:00:00Z","telemetry_id":"DC0061","collector":"illustrative-lab-collector","observation":{"path":"C:\\Lab\\demo.txt","attribute":"content_hash","before":"aaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaaa","after":"bbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbbb"}}]}}